23:26 ladsgroup@cumin1001: END (PASS) - Cookbook sre.hosts.downtime (exit_code=0) for 1 day, 0:00:00 on dbstore1003.eqiad.wmnet with reason: Maintenance
23:25 ladsgroup@cumin1001: START - Cookbook sre.hosts.downtime for 1 day, 0:00:00 on dbstore1003.eqiad.wmnet with reason: Maintenance
23:25 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db1196 (T314041)', diff saved to https://phabricator.wikimedia.org/P35243 and previous config saved to /var/cache/conftool/dbconfig/20220930-232546-ladsgroup.json
23:10 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db1196', diff saved to https://phabricator.wikimedia.org/P35242 and previous config saved to /var/cache/conftool/dbconfig/20220930-231040-ladsgroup.json
22:55 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db1196', diff saved to https://phabricator.wikimedia.org/P35241 and previous config saved to /var/cache/conftool/dbconfig/20220930-225534-ladsgroup.json
22:40 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db1196 (T314041)', diff saved to https://phabricator.wikimedia.org/P35240 and previous config saved to /var/cache/conftool/dbconfig/20220930-224027-ladsgroup.json
21:02 andrew@cumin1001: END (PASS) - Cookbook sre.hosts.reboot-single (exit_code=0) for host cloudbackup2001.codfw.wmnet
20:54 andrew@cumin1001: START - Cookbook sre.hosts.reboot-single for host cloudbackup2001.codfw.wmnet
18:30 robh@cumin2002: END (ERROR) - Cookbook sre.hosts.reimage (exit_code=97) for host cp4045.ulsfo.wmnet with OS bullseye
18:08 robh@cumin2002: START - Cookbook sre.hosts.reimage for host cp4045.ulsfo.wmnet with OS bullseye
18:01 robh@cumin2002: END (ERROR) - Cookbook sre.hosts.reimage (exit_code=97) for host cp4045.ulsfo.wmnet with OS bullseye
17:43 robh@cumin2002: START - Cookbook sre.hosts.reimage for host cp4045.ulsfo.wmnet with OS bullseye
17:24 bblack@cumin2002: END (ERROR) - Cookbook sre.hosts.reimage (exit_code=93) for host cp4045.ulsfo.wmnet with OS bullseye
17:06 ladsgroup@cumin1001: dbctl commit (dc=all): 'Depooling db1196 (T314041)', diff saved to https://phabricator.wikimedia.org/P35237 and previous config saved to /var/cache/conftool/dbconfig/20220930-170620-ladsgroup.json
17:06 ladsgroup@cumin1001: END (PASS) - Cookbook sre.hosts.downtime (exit_code=0) for 1 day, 0:00:00 on db1196.eqiad.wmnet with reason: Maintenance
17:05 ladsgroup@cumin1001: START - Cookbook sre.hosts.downtime for 1 day, 0:00:00 on db1196.eqiad.wmnet with reason: Maintenance
17:05 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db1186 (T314041)', diff saved to https://phabricator.wikimedia.org/P35236 and previous config saved to /var/cache/conftool/dbconfig/20220930-170546-ladsgroup.json
16:54 bblack@cumin2002: START - Cookbook sre.hosts.reimage for host cp4045.ulsfo.wmnet with OS bullseye
16:50 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db1186', diff saved to https://phabricator.wikimedia.org/P35235 and previous config saved to /var/cache/conftool/dbconfig/20220930-165040-ladsgroup.json
16:35 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db1186', diff saved to https://phabricator.wikimedia.org/P35234 and previous config saved to /var/cache/conftool/dbconfig/20220930-163533-ladsgroup.json
16:20 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db1186 (T314041)', diff saved to https://phabricator.wikimedia.org/P35233 and previous config saved to /var/cache/conftool/dbconfig/20220930-162027-ladsgroup.json
15:37 andrew@cumin1001: END (FAIL) - Cookbook sre.hosts.reimage (exit_code=99) for host cloudvirt1023.eqiad.wmnet with OS bullseye
14:41 andrew@cumin1001: START - Cookbook sre.hosts.reimage for host cloudvirt1023.eqiad.wmnet with OS bullseye
11:16 jmm@cumin2002: START - Cookbook sre.ganeti.makevm for new host puppetdb-test2001.codfw.wmnet
10:40 ladsgroup@cumin1001: dbctl commit (dc=all): 'Depooling db1186 (T314041)', diff saved to https://phabricator.wikimedia.org/P35223 and previous config saved to /var/cache/conftool/dbconfig/20220930-104004-ladsgroup.json
10:39 ladsgroup@cumin1001: END (PASS) - Cookbook sre.hosts.downtime (exit_code=0) for 1 day, 0:00:00 on db1186.eqiad.wmnet with reason: Maintenance
10:39 ladsgroup@cumin1001: START - Cookbook sre.hosts.downtime for 1 day, 0:00:00 on db1186.eqiad.wmnet with reason: Maintenance
10:39 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db1184 (T314041)', diff saved to https://phabricator.wikimedia.org/P35222 and previous config saved to /var/cache/conftool/dbconfig/20220930-103943-ladsgroup.json
10:24 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db1184', diff saved to https://phabricator.wikimedia.org/P35221 and previous config saved to /var/cache/conftool/dbconfig/20220930-102436-ladsgroup.json
10:09 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db1184', diff saved to https://phabricator.wikimedia.org/P35220 and previous config saved to /var/cache/conftool/dbconfig/20220930-100930-ladsgroup.json
09:54 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db1184 (T314041)', diff saved to https://phabricator.wikimedia.org/P35219 and previous config saved to /var/cache/conftool/dbconfig/20220930-095423-ladsgroup.json
09:42 moritzm: installing Linux 5.10.140 updates on Bullseye hosts (released via 11.5 point release), just rollout of the package, no reboots involved
07:37 XioNoX: add RPKI ROAs for 185.71.138.0/24 and 2001:67c:930::/48
07:17 ayounsi@cumin1001: END (PASS) - Cookbook sre.network.peering (exit_code=0) with action 'configure' for AS: 32934
07:10 ayounsi@cumin1001: START - Cookbook sre.network.peering with action 'configure' for AS: 32934
07:04 marostegui@cumin1001: dbctl commit (dc=all): 'db1166 (re)pooling @ 100%: After upgrade', diff saved to https://phabricator.wikimedia.org/P35218 and previous config saved to /var/cache/conftool/dbconfig/20220930-070454-root.json
06:58 marostegui@cumin1001: dbctl commit (dc=all): 'db1126 (re)pooling @ 100%: After upgrade', diff saved to https://phabricator.wikimedia.org/P35217 and previous config saved to /var/cache/conftool/dbconfig/20220930-065844-root.json
06:49 marostegui@cumin1001: dbctl commit (dc=all): 'db1166 (re)pooling @ 75%: After upgrade', diff saved to https://phabricator.wikimedia.org/P35216 and previous config saved to /var/cache/conftool/dbconfig/20220930-064949-root.json
06:43 marostegui@cumin1001: dbctl commit (dc=all): 'db1126 (re)pooling @ 75%: After upgrade', diff saved to https://phabricator.wikimedia.org/P35215 and previous config saved to /var/cache/conftool/dbconfig/20220930-064339-root.json
06:34 marostegui@cumin1001: dbctl commit (dc=all): 'db1166 (re)pooling @ 50%: After upgrade', diff saved to https://phabricator.wikimedia.org/P35214 and previous config saved to /var/cache/conftool/dbconfig/20220930-063444-root.json
06:28 marostegui@cumin1001: dbctl commit (dc=all): 'db1126 (re)pooling @ 50%: After upgrade', diff saved to https://phabricator.wikimedia.org/P35213 and previous config saved to /var/cache/conftool/dbconfig/20220930-062834-root.json
06:19 marostegui@cumin1001: dbctl commit (dc=all): 'db1166 (re)pooling @ 25%: After upgrade', diff saved to https://phabricator.wikimedia.org/P35212 and previous config saved to /var/cache/conftool/dbconfig/20220930-061939-root.json
06:13 marostegui@cumin1001: dbctl commit (dc=all): 'db1126 (re)pooling @ 25%: After upgrade', diff saved to https://phabricator.wikimedia.org/P35211 and previous config saved to /var/cache/conftool/dbconfig/20220930-061329-root.json
06:04 marostegui@cumin1001: dbctl commit (dc=all): 'db1166 (re)pooling @ 10%: After upgrade', diff saved to https://phabricator.wikimedia.org/P35210 and previous config saved to /var/cache/conftool/dbconfig/20220930-060434-root.json
05:58 marostegui@cumin1001: dbctl commit (dc=all): 'db1126 (re)pooling @ 10%: After upgrade', diff saved to https://phabricator.wikimedia.org/P35209 and previous config saved to /var/cache/conftool/dbconfig/20220930-055824-root.json
05:49 marostegui@cumin1001: dbctl commit (dc=all): 'db1166 (re)pooling @ 5%: After upgrade', diff saved to https://phabricator.wikimedia.org/P35208 and previous config saved to /var/cache/conftool/dbconfig/20220930-054929-root.json
05:43 marostegui@cumin1001: dbctl commit (dc=all): 'db1126 (re)pooling @ 5%: After upgrade', diff saved to https://phabricator.wikimedia.org/P35207 and previous config saved to /var/cache/conftool/dbconfig/20220930-054319-root.json
05:34 marostegui@cumin1001: dbctl commit (dc=all): 'db1166 (re)pooling @ 3%: After upgrade', diff saved to https://phabricator.wikimedia.org/P35206 and previous config saved to /var/cache/conftool/dbconfig/20220930-053424-root.json
05:28 marostegui@cumin1001: dbctl commit (dc=all): 'db1126 (re)pooling @ 3%: After upgrade', diff saved to https://phabricator.wikimedia.org/P35204 and previous config saved to /var/cache/conftool/dbconfig/20220930-052814-root.json
05:19 marostegui@cumin1001: dbctl commit (dc=all): 'db1166 (re)pooling @ 1%: After upgrade', diff saved to https://phabricator.wikimedia.org/P35203 and previous config saved to /var/cache/conftool/dbconfig/20220930-051919-root.json
05:13 marostegui@cumin1001: dbctl commit (dc=all): 'db1126 (re)pooling @ 1%: After upgrade', diff saved to https://phabricator.wikimedia.org/P35202 and previous config saved to /var/cache/conftool/dbconfig/20220930-051309-root.json
05:12 marostegui@cumin1001: dbctl commit (dc=all): 'Depool db1166', diff saved to https://phabricator.wikimedia.org/P35201 and previous config saved to /var/cache/conftool/dbconfig/20220930-051206-root.json
05:05 marostegui@cumin1001: dbctl commit (dc=all): 'Depool db1126', diff saved to https://phabricator.wikimedia.org/P35200 and previous config saved to /var/cache/conftool/dbconfig/20220930-050533-root.json
04:19 ladsgroup@cumin1001: dbctl commit (dc=all): 'Depooling db1184 (T314041)', diff saved to https://phabricator.wikimedia.org/P35199 and previous config saved to /var/cache/conftool/dbconfig/20220930-041937-ladsgroup.json
04:19 ladsgroup@cumin1001: END (PASS) - Cookbook sre.hosts.downtime (exit_code=0) for 1 day, 0:00:00 on db1184.eqiad.wmnet with reason: Maintenance
04:19 ladsgroup@cumin1001: START - Cookbook sre.hosts.downtime for 1 day, 0:00:00 on db1184.eqiad.wmnet with reason: Maintenance
04:19 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db1169 (T314041)', diff saved to https://phabricator.wikimedia.org/P35198 and previous config saved to /var/cache/conftool/dbconfig/20220930-041916-ladsgroup.json
04:04 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db1169', diff saved to https://phabricator.wikimedia.org/P35197 and previous config saved to /var/cache/conftool/dbconfig/20220930-040409-ladsgroup.json
03:49 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db1169', diff saved to https://phabricator.wikimedia.org/P35196 and previous config saved to /var/cache/conftool/dbconfig/20220930-034903-ladsgroup.json
03:33 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db1169 (T314041)', diff saved to https://phabricator.wikimedia.org/P35195 and previous config saved to /var/cache/conftool/dbconfig/20220930-033356-ladsgroup.json
00:31 robh@cumin2002: END (ERROR) - Cookbook sre.hosts.reimage (exit_code=97) for host cp4045.ulsfo.wmnet with OS bullseye
00:22 robh@cumin2002: START - Cookbook sre.hosts.reimage for host cp4045.ulsfo.wmnet with OS bullseye
2022-09-29
22:46 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db2176 (T314041)', diff saved to https://phabricator.wikimedia.org/P35193 and previous config saved to /var/cache/conftool/dbconfig/20220929-224649-ladsgroup.json
22:31 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db2176', diff saved to https://phabricator.wikimedia.org/P35192 and previous config saved to /var/cache/conftool/dbconfig/20220929-223143-ladsgroup.json
22:16 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db2176', diff saved to https://phabricator.wikimedia.org/P35191 and previous config saved to /var/cache/conftool/dbconfig/20220929-221637-ladsgroup.json
22:01 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db2176 (T314041)', diff saved to https://phabricator.wikimedia.org/P35190 and previous config saved to /var/cache/conftool/dbconfig/20220929-220130-ladsgroup.json
21:53 ladsgroup@cumin1001: dbctl commit (dc=all): 'Depooling db1169 (T314041)', diff saved to https://phabricator.wikimedia.org/P35189 and previous config saved to /var/cache/conftool/dbconfig/20220929-215333-ladsgroup.json
21:53 ladsgroup@cumin1001: END (PASS) - Cookbook sre.hosts.downtime (exit_code=0) for 1 day, 0:00:00 on db1169.eqiad.wmnet with reason: Maintenance
21:53 ladsgroup@cumin1001: START - Cookbook sre.hosts.downtime for 1 day, 0:00:00 on db1169.eqiad.wmnet with reason: Maintenance
21:06 brennen@deploy1002: brennen and ebernhardson: Backport for cirrus: Don't configure cloud clusters for private wikis synced to the testservers: mwdebug1002.eqiad.wmnet, mwdebug2001.codfw.wmnet, mwdebug2002.codfw.wmnet, mwdebug1001.eqiad.wmnet
20:45 brennen@deploy1002: brennen and trainbranchbot: Backport for Revert "Add Nepalese Wikipedia tagline" synced to the testservers: mwdebug1001.eqiad.wmnet, mwdebug2001.codfw.wmnet, mwdebug2002.codfw.wmnet, mwdebug1002.eqiad.wmnet
20:45 cmjohnson@cumin1001: END (FAIL) - Cookbook sre.hosts.reimage (exit_code=99) for host kafka-stretch1001.eqiad.wmnet with OS bullseye
20:42 brennen@deploy1002: Sync cancelled.
20:41 brennen@deploy1002: brennen and jdlrobson: Backport for Add Nepalese Wikipedia tagline (T318737) synced to the testservers: mwdebug1002.eqiad.wmnet, mwdebug1001.eqiad.wmnet, mwdebug2002.codfw.wmnet, mwdebug2001.codfw.wmnet
20:41 ryankemper: T313431 Restarting elasticsearch_7* services on `elastic2080` to pick up new master-eligible status
20:33 robh@cumin2002: START - Cookbook sre.hosts.decommission for hosts cp4027.ulsfo.wmnet
20:30 brennen@deploy1002: brennen and jdlrobson: Backport for Enable desktop improvements on nowikimedia (T318344) synced to the testservers: mwdebug2001.codfw.wmnet, mwdebug2002.codfw.wmnet, mwdebug1001.eqiad.wmnet, mwdebug1002.eqiad.wmnet
20:19 hoo: Ran foreachwikiindblist wikidataclient-test extensions/Wikibase/client/maintenance/PopulateUnexpectedUnconnectedPagePageProp.php
20:17 ejegg: payments-wiki upgraded from 0456850e to 839d6dde (with cache prefix altered for moved classes)
20:17 ryankemper: T313431 Restarting elasticsearch_7* services on `elastic2086` to pick up new master-eligible status
20:17 brennen@deploy1002: brennen and jdlrobson: Backport for Web team config cleanup (T316568) synced to the testservers: mwdebug2002.codfw.wmnet, mwdebug1002.eqiad.wmnet, mwdebug2001.codfw.wmnet, mwdebug1001.eqiad.wmnet
19:03 cmjohnson@cumin1001: END (PASS) - Cookbook sre.hosts.provision (exit_code=0) for host cloudvirt1061.mgmt.eqiad.wmnet with reboot policy FORCED
19:02 cmjohnson@cumin1001: END (PASS) - Cookbook sre.hosts.provision (exit_code=0) for host cloudvirt1059.mgmt.eqiad.wmnet with reboot policy FORCED
19:02 cmjohnson@cumin1001: END (PASS) - Cookbook sre.hosts.provision (exit_code=0) for host cloudvirt1058.mgmt.eqiad.wmnet with reboot policy FORCED
19:02 cmjohnson@cumin1001: END (PASS) - Cookbook sre.hosts.provision (exit_code=0) for host cloudvirt1057.mgmt.eqiad.wmnet with reboot policy FORCED
19:02 cmjohnson@cumin1001: END (PASS) - Cookbook sre.hosts.provision (exit_code=0) for host cloudvirt1056.mgmt.eqiad.wmnet with reboot policy FORCED
19:02 cmjohnson@cumin1001: END (PASS) - Cookbook sre.hosts.provision (exit_code=0) for host cloudvirt1055.mgmt.eqiad.wmnet with reboot policy FORCED
18:59 robh@cumin2002: START - Cookbook sre.hosts.decommission for hosts cp4021.ulsfo.wmnet
18:56 cmjohnson@cumin1001: END (PASS) - Cookbook sre.hosts.provision (exit_code=0) for host cloudvirt1054.mgmt.eqiad.wmnet with reboot policy FORCED
18:45 cmjohnson@cumin1001: END (PASS) - Cookbook sre.hosts.provision (exit_code=0) for host kafka-stretch1002.mgmt.eqiad.wmnet with reboot policy FORCED
18:43 cmjohnson@cumin1001: START - Cookbook sre.hosts.provision for host cloudvirt1061.mgmt.eqiad.wmnet with reboot policy FORCED
18:42 cmjohnson@cumin1001: START - Cookbook sre.hosts.provision for host cloudvirt1060.mgmt.eqiad.wmnet with reboot policy FORCED
18:42 cmjohnson@cumin1001: START - Cookbook sre.hosts.provision for host cloudvirt1059.mgmt.eqiad.wmnet with reboot policy FORCED
18:41 cmjohnson@cumin1001: START - Cookbook sre.hosts.provision for host cloudvirt1058.mgmt.eqiad.wmnet with reboot policy FORCED
18:41 cmjohnson@cumin1001: START - Cookbook sre.hosts.provision for host cloudvirt1057.mgmt.eqiad.wmnet with reboot policy FORCED
18:40 cmjohnson@cumin1001: START - Cookbook sre.hosts.provision for host cloudvirt1056.mgmt.eqiad.wmnet with reboot policy FORCED
18:40 cmjohnson@cumin1001: START - Cookbook sre.hosts.provision for host cloudvirt1055.mgmt.eqiad.wmnet with reboot policy FORCED
18:39 cmjohnson@cumin1001: START - Cookbook sre.hosts.provision for host cloudvirt1054.mgmt.eqiad.wmnet with reboot policy FORCED
18:33 cmjohnson@cumin1001: END (PASS) - Cookbook sre.hosts.provision (exit_code=0) for host kafka-stretch1001.mgmt.eqiad.wmnet with reboot policy FORCED
16:48 ladsgroup@cumin1001: END (PASS) - Cookbook sre.hosts.downtime (exit_code=0) for 1 day, 0:00:00 on db1140.eqiad.wmnet with reason: Maintenance
16:47 ladsgroup@cumin1001: START - Cookbook sre.hosts.downtime for 1 day, 0:00:00 on db1140.eqiad.wmnet with reason: Maintenance
16:28 ladsgroup@cumin1001: dbctl commit (dc=all): 'Depooling db2176 (T314041)', diff saved to https://phabricator.wikimedia.org/P35188 and previous config saved to /var/cache/conftool/dbconfig/20220929-162812-ladsgroup.json
16:28 ladsgroup@cumin1001: END (PASS) - Cookbook sre.hosts.downtime (exit_code=0) for 1 day, 0:00:00 on db2176.codfw.wmnet with reason: Maintenance
16:27 ladsgroup@cumin1001: START - Cookbook sre.hosts.downtime for 1 day, 0:00:00 on db2176.codfw.wmnet with reason: Maintenance
16:27 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db2174 (T314041)', diff saved to https://phabricator.wikimedia.org/P35187 and previous config saved to /var/cache/conftool/dbconfig/20220929-162750-ladsgroup.json
16:12 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db2174', diff saved to https://phabricator.wikimedia.org/P35186 and previous config saved to /var/cache/conftool/dbconfig/20220929-161244-ladsgroup.json
15:57 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db2174', diff saved to https://phabricator.wikimedia.org/P35185 and previous config saved to /var/cache/conftool/dbconfig/20220929-155737-ladsgroup.json
15:42 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db2174 (T314041)', diff saved to https://phabricator.wikimedia.org/P35184 and previous config saved to /var/cache/conftool/dbconfig/20220929-154231-ladsgroup.json
15:35 dancy@deploy1002: Installation of scap version "4.25.0" completed for 561 hosts
15:35 dancy@deploy1002: Installing scap version "4.25.0" for 561 hosts
13:37 ayounsi@cumin1001: START - Cookbook sre.network.peering with action 'configure' for AS: 8966
13:35 lucaswerkmeister-wmde@deploy1002: lucaswerkmeister-wmde and hoo: Backport for Wikibase: Set UnconnectedPage page prop format for test wikis synced to the testservers: mwdebug1002.eqiad.wmnet, mwdebug2001.codfw.wmnet, mwdebug2002.codfw.wmnet, mwdebug1001.eqiad.wmnet
13:28 lucaswerkmeister-wmde@deploy1002: lucaswerkmeister-wmde and kemayo: Backport for Stop mobile visual enhancements from rolling out to jawiki (T318871) synced to the testservers: mwdebug1002.eqiad.wmnet, mwdebug2002.codfw.wmnet, mwdebug1001.eqiad.wmnet, mwdebug2001.codfw.wmnet
13:18 marostegui@cumin1001: dbctl commit (dc=all): 'db1178 (re)pooling @ 50%: After upgrade', diff saved to https://phabricator.wikimedia.org/P35176 and previous config saved to /var/cache/conftool/dbconfig/20220929-131834-root.json
13:15 lucaswerkmeister-wmde@deploy1002: lucaswerkmeister-wmde and lucaswerkmeister-wmde: Backport for Remove wmgEntityUsageModifierLimitsStatement on cebwiki (T296384) synced to the testservers: mwdebug1002.eqiad.wmnet, mwdebug1001.eqiad.wmnet, mwdebug2002.codfw.wmnet, mwdebug2001.codfw.wmnet
11:51 ayounsi@cumin1001: END (PASS) - Cookbook sre.network.peering (exit_code=0) with action 'configure' for AS: 15695
11:48 ayounsi@cumin1001: START - Cookbook sre.network.peering with action 'configure' for AS: 15695
11:45 ayounsi@cumin1001: END (ERROR) - Cookbook sre.network.peering (exit_code=97) with action 'configure' for AS: 42
11:45 ayounsi@cumin1001: START - Cookbook sre.network.peering with action 'configure' for AS: 42
11:44 ayounsi@cumin1001: END (PASS) - Cookbook sre.network.peering (exit_code=0) with action 'configure' for AS: 3856
11:44 ladsgroup@cumin1001: END (PASS) - Cookbook sre.hosts.downtime (exit_code=0) for 1 day, 0:00:00 on db1139.eqiad.wmnet with reason: Maintenance
11:44 marostegui@cumin1001: dbctl commit (dc=all): 'db2161 (re)pooling @ 3%: After upgrade', diff saved to https://phabricator.wikimedia.org/P35162 and previous config saved to /var/cache/conftool/dbconfig/20220929-114438-root.json
11:44 ladsgroup@cumin1001: START - Cookbook sre.hosts.downtime for 1 day, 0:00:00 on db1139.eqiad.wmnet with reason: Maintenance
11:44 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db1135 (T314041)', diff saved to https://phabricator.wikimedia.org/P35161 and previous config saved to /var/cache/conftool/dbconfig/20220929-114431-ladsgroup.json
11:41 ayounsi@cumin1001: START - Cookbook sre.network.peering with action 'configure' for AS: 3856
11:41 ayounsi@cumin1001: END (PASS) - Cookbook sre.network.peering (exit_code=0) with action 'configure' for AS: 42
11:37 ayounsi@cumin1001: START - Cookbook sre.network.peering with action 'configure' for AS: 62955
11:29 marostegui@cumin1001: dbctl commit (dc=all): 'db2161 (re)pooling @ 1%: After upgrade', diff saved to https://phabricator.wikimedia.org/P35160 and previous config saved to /var/cache/conftool/dbconfig/20220929-112933-root.json
11:29 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db1135', diff saved to https://phabricator.wikimedia.org/P35159 and previous config saved to /var/cache/conftool/dbconfig/20220929-112925-ladsgroup.json
11:14 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db1135', diff saved to https://phabricator.wikimedia.org/P35158 and previous config saved to /var/cache/conftool/dbconfig/20220929-111418-ladsgroup.json
11:12 marostegui@cumin1001: dbctl commit (dc=all): 'Depool db2161 T318892', diff saved to https://phabricator.wikimedia.org/P35157 and previous config saved to /var/cache/conftool/dbconfig/20220929-111217-root.json
11:11 marostegui@cumin1001: dbctl commit (dc=all): 'Promote db2165 to s8 codfw primary T318892', diff saved to https://phabricator.wikimedia.org/P35156 and previous config saved to /var/cache/conftool/dbconfig/20220929-111127-root.json
11:10 marostegui: Starting s8 codfw failover from db2161 to db2165 - T318892
11:06 XioNoX: restart cr2-eqord for upgrade - T295690
11:05 jmm@cumin2002: END (PASS) - Cookbook sre.misc-clusters.roll-restart-reboot-eventschemas (exit_code=0) rolling restart_daemons on A:schema-eqiad
11:04 jmm@cumin2002: START - Cookbook sre.misc-clusters.roll-restart-reboot-eventschemas rolling restart_daemons on A:schema-eqiad
11:02 jmm@cumin2002: END (PASS) - Cookbook sre.misc-clusters.roll-restart-reboot-eventschemas (exit_code=0) rolling restart_daemons on A:schema-codfw
11:01 jmm@cumin2002: START - Cookbook sre.misc-clusters.roll-restart-reboot-eventschemas rolling restart_daemons on A:schema-codfw
10:59 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db1135 (T314041)', diff saved to https://phabricator.wikimedia.org/P35155 and previous config saved to /var/cache/conftool/dbconfig/20220929-105912-ladsgroup.json
10:08 ladsgroup@cumin1001: dbctl commit (dc=all): 'Depooling db2174 (T314041)', diff saved to https://phabricator.wikimedia.org/P35153 and previous config saved to /var/cache/conftool/dbconfig/20220929-100849-ladsgroup.json
10:08 ladsgroup@cumin1001: END (PASS) - Cookbook sre.hosts.downtime (exit_code=0) for 1 day, 0:00:00 on db2174.codfw.wmnet with reason: Maintenance
10:08 ladsgroup@cumin1001: START - Cookbook sre.hosts.downtime for 1 day, 0:00:00 on db2174.codfw.wmnet with reason: Maintenance
10:08 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db2173 (T314041)', diff saved to https://phabricator.wikimedia.org/P35152 and previous config saved to /var/cache/conftool/dbconfig/20220929-100828-ladsgroup.json
10:07 XioNoX: second (and longest) cr2-eqiad RE switchover - T295690
09:53 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db2173', diff saved to https://phabricator.wikimedia.org/P35150 and previous config saved to /var/cache/conftool/dbconfig/20220929-095321-ladsgroup.json
09:45 moritzm: restarting superset to pick up expat security update
09:38 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db2173', diff saved to https://phabricator.wikimedia.org/P35149 and previous config saved to /var/cache/conftool/dbconfig/20220929-093815-ladsgroup.json
09:29 ayounsi@cumin1001: END (PASS) - Cookbook sre.hosts.downtime (exit_code=0) for 4:00:00 on cr2-eqiad,cr2-eqiad IPv6,re0.cr2-eqiad.mgmt with reason: router upgrade
09:28 ayounsi@cumin1001: START - Cookbook sre.hosts.downtime for 4:00:00 on cr2-eqiad,cr2-eqiad IPv6,re0.cr2-eqiad.mgmt with reason: router upgrade
09:26 jynus@cumin2002: END (PASS) - Cookbook sre.hosts.reimage (exit_code=0) for host db2098.codfw.wmnet with OS bullseye
09:23 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db2173 (T314041)', diff saved to https://phabricator.wikimedia.org/P35148 and previous config saved to /var/cache/conftool/dbconfig/20220929-092308-ladsgroup.json
08:15 XioNoX: first cr1-eqiad RE switchover (for NVM firmware) - T295690
08:12 marostegui@cumin1001: dbctl commit (dc=all): 'db1177 (re)pooling @ 75%: After upgrade', diff saved to https://phabricator.wikimedia.org/P35145 and previous config saved to /var/cache/conftool/dbconfig/20220929-081252-root.json
08:03 marostegui@cumin1001: dbctl commit (dc=all): 'db2121 (re)pooling @ 100%: After upgrade', diff saved to https://phabricator.wikimedia.org/P35144 and previous config saved to /var/cache/conftool/dbconfig/20220929-080340-root.json
07:57 XioNoX: drain traffic away from cr1-eqiad - T295690
07:57 marostegui@cumin1001: dbctl commit (dc=all): 'db1177 (re)pooling @ 50%: After upgrade', diff saved to https://phabricator.wikimedia.org/P35143 and previous config saved to /var/cache/conftool/dbconfig/20220929-075747-root.json
07:49 ayounsi@cumin1001: END (PASS) - Cookbook sre.hosts.downtime (exit_code=0) for 4:00:00 on cr1-eqiad,cr1-eqiad IPv6,re0.cr1-eqiad.mgmt with reason: router upgrade
07:49 ayounsi@cumin1001: START - Cookbook sre.hosts.downtime for 4:00:00 on cr1-eqiad,cr1-eqiad IPv6,re0.cr1-eqiad.mgmt with reason: router upgrade
07:48 marostegui@cumin1001: dbctl commit (dc=all): 'db2121 (re)pooling @ 75%: After upgrade', diff saved to https://phabricator.wikimedia.org/P35142 and previous config saved to /var/cache/conftool/dbconfig/20220929-074835-root.json
07:45 moritzm: installing expat security updates
07:42 marostegui@cumin1001: dbctl commit (dc=all): 'db1177 (re)pooling @ 25%: After upgrade', diff saved to https://phabricator.wikimedia.org/P35141 and previous config saved to /var/cache/conftool/dbconfig/20220929-074242-root.json
07:42 ayounsi@cumin1001: END (PASS) - Cookbook sre.network.peering (exit_code=0) with action 'configure' for AS: 18106
07:40 ayounsi@cumin1001: START - Cookbook sre.network.peering with action 'configure' for AS: 18106
07:38 ayounsi@cumin1001: END (PASS) - Cookbook sre.network.peering (exit_code=0) with action 'configure' for AS: 38040
07:38 ayounsi@cumin1001: START - Cookbook sre.network.peering with action 'configure' for AS: 38040
07:36 ayounsi@cumin1001: END (PASS) - Cookbook sre.network.peering (exit_code=0) with action 'configure' for AS: 35280
07:34 ayounsi@cumin1001: START - Cookbook sre.network.peering with action 'configure' for AS: 35280
07:33 marostegui@cumin1001: dbctl commit (dc=all): 'db2121 (re)pooling @ 50%: After upgrade', diff saved to https://phabricator.wikimedia.org/P35140 and previous config saved to /var/cache/conftool/dbconfig/20220929-073330-root.json
07:27 marostegui@cumin1001: dbctl commit (dc=all): 'db2110 (re)pooling @ 100%: After upgrade', diff saved to https://phabricator.wikimedia.org/P35139 and previous config saved to /var/cache/conftool/dbconfig/20220929-072745-root.json
07:27 marostegui@cumin1001: dbctl commit (dc=all): 'db1177 (re)pooling @ 10%: After upgrade', diff saved to https://phabricator.wikimedia.org/P35138 and previous config saved to /var/cache/conftool/dbconfig/20220929-072737-root.json
07:18 marostegui@cumin1001: dbctl commit (dc=all): 'db2121 (re)pooling @ 25%: After upgrade', diff saved to https://phabricator.wikimedia.org/P35137 and previous config saved to /var/cache/conftool/dbconfig/20220929-071825-root.json
07:12 marostegui@cumin1001: dbctl commit (dc=all): 'db2110 (re)pooling @ 75%: After upgrade', diff saved to https://phabricator.wikimedia.org/P35136 and previous config saved to /var/cache/conftool/dbconfig/20220929-071240-root.json
07:12 marostegui@cumin1001: dbctl commit (dc=all): 'db1177 (re)pooling @ 5%: After upgrade', diff saved to https://phabricator.wikimedia.org/P35135 and previous config saved to /var/cache/conftool/dbconfig/20220929-071232-root.json
07:03 marostegui@cumin1001: dbctl commit (dc=all): 'db2121 (re)pooling @ 10%: After upgrade', diff saved to https://phabricator.wikimedia.org/P35134 and previous config saved to /var/cache/conftool/dbconfig/20220929-070320-root.json
06:57 marostegui@cumin1001: dbctl commit (dc=all): 'db2110 (re)pooling @ 50%: After upgrade', diff saved to https://phabricator.wikimedia.org/P35133 and previous config saved to /var/cache/conftool/dbconfig/20220929-065736-root.json
06:57 marostegui@cumin1001: dbctl commit (dc=all): 'db1177 (re)pooling @ 3%: After upgrade', diff saved to https://phabricator.wikimedia.org/P35132 and previous config saved to /var/cache/conftool/dbconfig/20220929-065727-root.json
06:48 marostegui@cumin1001: dbctl commit (dc=all): 'db2121 (re)pooling @ 5%: After upgrade', diff saved to https://phabricator.wikimedia.org/P35131 and previous config saved to /var/cache/conftool/dbconfig/20220929-064815-root.json
06:42 marostegui@cumin1001: dbctl commit (dc=all): 'db2110 (re)pooling @ 25%: After upgrade', diff saved to https://phabricator.wikimedia.org/P35130 and previous config saved to /var/cache/conftool/dbconfig/20220929-064231-root.json
06:42 marostegui@cumin1001: dbctl commit (dc=all): 'db1177 (re)pooling @ 1%: After upgrade', diff saved to https://phabricator.wikimedia.org/P35129 and previous config saved to /var/cache/conftool/dbconfig/20220929-064222-root.json
06:35 marostegui@cumin1001: dbctl commit (dc=all): 'Depool db1177', diff saved to https://phabricator.wikimedia.org/P35128 and previous config saved to /var/cache/conftool/dbconfig/20220929-063508-root.json
06:34 ayounsi@cumin1001: END (PASS) - Cookbook sre.network.prepare-upgrade (exit_code=0)
06:34 ayounsi@cumin1001: END (PASS) - Cookbook sre.network.prepare-upgrade (exit_code=0)
06:33 marostegui@cumin1001: dbctl commit (dc=all): 'db2121 (re)pooling @ 3%: After upgrade', diff saved to https://phabricator.wikimedia.org/P35127 and previous config saved to /var/cache/conftool/dbconfig/20220929-063310-root.json
06:18 marostegui@cumin1001: dbctl commit (dc=all): 'db2121 (re)pooling @ 1%: After upgrade', diff saved to https://phabricator.wikimedia.org/P35125 and previous config saved to /var/cache/conftool/dbconfig/20220929-061805-root.json
06:12 marostegui@cumin1001: dbctl commit (dc=all): 'db2110 (re)pooling @ 5%: After upgrade', diff saved to https://phabricator.wikimedia.org/P35124 and previous config saved to /var/cache/conftool/dbconfig/20220929-061221-root.json
06:05 marostegui@cumin1001: dbctl commit (dc=all): 'Depool db2121 T318888', diff saved to https://phabricator.wikimedia.org/P35123 and previous config saved to /var/cache/conftool/dbconfig/20220929-060532-root.json
06:04 marostegui@cumin1001: dbctl commit (dc=all): 'Promote db2118 to s7 primary and set section read-write T318888', diff saved to https://phabricator.wikimedia.org/P35122 and previous config saved to /var/cache/conftool/dbconfig/20220929-060425-root.json
06:03 marostegui: Starting s7 codfw failover from db2121 to db2118 - T318888
05:57 marostegui@cumin1001: dbctl commit (dc=all): 'db2110 (re)pooling @ 3%: After upgrade', diff saved to https://phabricator.wikimedia.org/P35121 and previous config saved to /var/cache/conftool/dbconfig/20220929-055716-root.json
05:45 marostegui@cumin1001: dbctl commit (dc=all): 'Depool db2118 from API T318888', diff saved to https://phabricator.wikimedia.org/P35120 and previous config saved to /var/cache/conftool/dbconfig/20220929-054542-root.json
05:45 marostegui@cumin1001: dbctl commit (dc=all): 'Set db2118 with weight 0 T318888', diff saved to https://phabricator.wikimedia.org/P35119 and previous config saved to /var/cache/conftool/dbconfig/20220929-054509-root.json
05:45 marostegui@cumin1001: END (PASS) - Cookbook sre.hosts.downtime (exit_code=0) for 1:00:00 on 30 hosts with reason: Primary switchover s7 T318888
05:44 marostegui@cumin1001: START - Cookbook sre.hosts.downtime for 1:00:00 on 30 hosts with reason: Primary switchover s7 T318888
05:42 marostegui@cumin1001: dbctl commit (dc=all): 'db2110 (re)pooling @ 1%: After upgrade', diff saved to https://phabricator.wikimedia.org/P35118 and previous config saved to /var/cache/conftool/dbconfig/20220929-054211-root.json
05:39 marostegui@cumin1001: dbctl commit (dc=all): 'Depool db2140 from API T318886', diff saved to https://phabricator.wikimedia.org/P35117 and previous config saved to /var/cache/conftool/dbconfig/20220929-053951-root.json
05:34 marostegui@cumin1001: dbctl commit (dc=all): 'Depool db2110 T318886', diff saved to https://phabricator.wikimedia.org/P35116 and previous config saved to /var/cache/conftool/dbconfig/20220929-053407-root.json
05:33 marostegui@cumin1001: dbctl commit (dc=all): 'Promote db2140 to s4 primary and set section read-write T318886', diff saved to https://phabricator.wikimedia.org/P35115 and previous config saved to /var/cache/conftool/dbconfig/20220929-053302-root.json
05:32 marostegui: Starting s4 codfw failover from db2110 to db2140 - T318886
05:28 ladsgroup@cumin1001: dbctl commit (dc=all): 'Depooling db1135 (T314041)', diff saved to https://phabricator.wikimedia.org/P35114 and previous config saved to /var/cache/conftool/dbconfig/20220929-052805-ladsgroup.json
05:27 ladsgroup@cumin1001: END (PASS) - Cookbook sre.hosts.downtime (exit_code=0) for 1 day, 0:00:00 on db1135.eqiad.wmnet with reason: Maintenance
05:27 ladsgroup@cumin1001: START - Cookbook sre.hosts.downtime for 1 day, 0:00:00 on db1135.eqiad.wmnet with reason: Maintenance
05:27 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db1134 (T314041)', diff saved to https://phabricator.wikimedia.org/P35113 and previous config saved to /var/cache/conftool/dbconfig/20220929-052743-ladsgroup.json
05:12 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db1134', diff saved to https://phabricator.wikimedia.org/P35112 and previous config saved to /var/cache/conftool/dbconfig/20220929-051237-ladsgroup.json
05:11 marostegui@cumin1001: END (PASS) - Cookbook sre.hosts.downtime (exit_code=0) for 1:00:00 on 34 hosts with reason: Primary switchover s4 T318886
05:11 marostegui@cumin1001: dbctl commit (dc=all): 'Set db2140 with weight 0 T318886', diff saved to https://phabricator.wikimedia.org/P35111 and previous config saved to /var/cache/conftool/dbconfig/20220929-051114-root.json
05:10 marostegui@cumin1001: START - Cookbook sre.hosts.downtime for 1:00:00 on 34 hosts with reason: Primary switchover s4 T318886
04:57 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db1134', diff saved to https://phabricator.wikimedia.org/P35110 and previous config saved to /var/cache/conftool/dbconfig/20220929-045730-ladsgroup.json
04:42 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db1134 (T314041)', diff saved to https://phabricator.wikimedia.org/P35109 and previous config saved to /var/cache/conftool/dbconfig/20220929-044224-ladsgroup.json
03:57 ladsgroup@cumin1001: dbctl commit (dc=all): 'Depooling db2173 (T314041)', diff saved to https://phabricator.wikimedia.org/P35108 and previous config saved to /var/cache/conftool/dbconfig/20220929-035724-ladsgroup.json
03:57 ladsgroup@cumin1001: END (PASS) - Cookbook sre.hosts.downtime (exit_code=0) for 2 days, 0:00:00 on db2094.codfw.wmnet with reason: Maintenance
03:57 ladsgroup@cumin1001: START - Cookbook sre.hosts.downtime for 2 days, 0:00:00 on db2094.codfw.wmnet with reason: Maintenance
03:57 ladsgroup@cumin1001: END (PASS) - Cookbook sre.hosts.downtime (exit_code=0) for 1 day, 0:00:00 on db2173.codfw.wmnet with reason: Maintenance
03:56 ladsgroup@cumin1001: START - Cookbook sre.hosts.downtime for 1 day, 0:00:00 on db2173.codfw.wmnet with reason: Maintenance
03:56 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db2170:3311 (T314041)', diff saved to https://phabricator.wikimedia.org/P35107 and previous config saved to /var/cache/conftool/dbconfig/20220929-035647-ladsgroup.json
03:41 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db2170:3311', diff saved to https://phabricator.wikimedia.org/P35106 and previous config saved to /var/cache/conftool/dbconfig/20220929-034140-ladsgroup.json
03:40 bmansurov@deploy1002: Started deploy [airflow-dags/research@b9be20d]: (no justification provided)
03:26 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db2170:3311', diff saved to https://phabricator.wikimedia.org/P35105 and previous config saved to /var/cache/conftool/dbconfig/20220929-032634-ladsgroup.json
03:11 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db2170:3311 (T314041)', diff saved to https://phabricator.wikimedia.org/P35104 and previous config saved to /var/cache/conftool/dbconfig/20220929-031127-ladsgroup.json
02:29 ejegg: updated fundraising CiviCRM from f3461a44 to 5e1738a1
02:20 ejegg: updated fundraising python tools from dd494413 to 14d60435
01:01 pt1979@cumin2002: END (PASS) - Cookbook sre.hosts.reimage (exit_code=0) for host logstash2037.codfw.wmnet with OS buster
00:46 pt1979@cumin2002: END (PASS) - Cookbook sre.hosts.downtime (exit_code=0) for 2:00:00 on logstash2037.codfw.wmnet with reason: host reimage
00:43 pt1979@cumin2002: START - Cookbook sre.hosts.downtime for 2:00:00 on logstash2037.codfw.wmnet with reason: host reimage
2022-09-28
23:53 pt1979@cumin2002: START - Cookbook sre.hosts.reimage for host logstash2037.codfw.wmnet with OS buster
23:52 pt1979@cumin2002: END (PASS) - Cookbook sre.hardware.upgrade-firmware (exit_code=0) upgrade firmware for hosts ['logstash2037']
23:17 ladsgroup@cumin1001: dbctl commit (dc=all): 'Depooling db1134 (T314041)', diff saved to https://phabricator.wikimedia.org/P35103 and previous config saved to /var/cache/conftool/dbconfig/20220928-231719-ladsgroup.json
23:17 ladsgroup@cumin1001: END (PASS) - Cookbook sre.hosts.downtime (exit_code=0) for 1 day, 0:00:00 on db1134.eqiad.wmnet with reason: Maintenance
23:17 ladsgroup@cumin1001: START - Cookbook sre.hosts.downtime for 1 day, 0:00:00 on db1134.eqiad.wmnet with reason: Maintenance
22:20 ejegg: updated fundraising CiviCRM from d31c19a0 to f3461a44
21:37 ladsgroup@cumin1001: dbctl commit (dc=all): 'Depooling db2170:3311 (T314041)', diff saved to https://phabricator.wikimedia.org/P35102 and previous config saved to /var/cache/conftool/dbconfig/20220928-213701-ladsgroup.json
21:36 ladsgroup@cumin1001: END (PASS) - Cookbook sre.hosts.downtime (exit_code=0) for 1 day, 0:00:00 on db2170.codfw.wmnet with reason: Maintenance
21:36 ladsgroup@cumin1001: START - Cookbook sre.hosts.downtime for 1 day, 0:00:00 on db2170.codfw.wmnet with reason: Maintenance
21:36 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db2167:3311 (T314041)', diff saved to https://phabricator.wikimedia.org/P35101 and previous config saved to /var/cache/conftool/dbconfig/20220928-213640-ladsgroup.json
21:21 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db2167:3311', diff saved to https://phabricator.wikimedia.org/P35100 and previous config saved to /var/cache/conftool/dbconfig/20220928-212131-ladsgroup.json
21:06 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db2167:3311', diff saved to https://phabricator.wikimedia.org/P35099 and previous config saved to /var/cache/conftool/dbconfig/20220928-210624-ladsgroup.json
21:06 volans: installed spicerack 4.0.0-1+deb11u1 on cumin1001
20:59 cmjohnson@cumin1001: END (PASS) - Cookbook sre.dns.netbox (exit_code=0)
20:51 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db2167:3311 (T314041)', diff saved to https://phabricator.wikimedia.org/P35098 and previous config saved to /var/cache/conftool/dbconfig/20220928-205117-ladsgroup.json
20:50 ayounsi@cumin1001: END (PASS) - Cookbook sre.network.peering (exit_code=0) with action 'configure' for AS: 12200
20:50 ayounsi@cumin1001: START - Cookbook sre.network.peering with action 'configure' for AS: 12200
20:39 TheresNoTime: closing UTC late backport window
20:08 volans@cumin2002: END (PASS) - Cookbook sre.hosts.provision (exit_code=0) for host logstash2037.mgmt.codfw.wmnet with reboot policy FORCED
20:04 samtar@deploy1002: samtar and dani: Backport for Deploy Research Incentive survey on arwiki (T318328) synced to the testservers: mwdebug2001.codfw.wmnet, mwdebug1001.eqiad.wmnet, mwdebug1002.eqiad.wmnet, mwdebug2002.codfw.wmnet
17:19 ladsgroup@cumin1001: END (PASS) - Cookbook sre.hosts.downtime (exit_code=0) for 1 day, 0:00:00 on db1133.eqiad.wmnet with reason: Maintenance
17:18 ladsgroup@cumin1001: START - Cookbook sre.hosts.downtime for 1 day, 0:00:00 on db1133.eqiad.wmnet with reason: Maintenance
17:18 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db1132 (T314041)', diff saved to https://phabricator.wikimedia.org/P35097 and previous config saved to /var/cache/conftool/dbconfig/20220928-171848-ladsgroup.json
17:16 cmjohnson@cumin1001: END (ERROR) - Cookbook sre.hosts.reimage (exit_code=97) for host kubernetes1024.eqiad.wmnet with OS bullseye
17:12 cmjohnson@cumin1001: START - Cookbook sre.hosts.reimage for host kubernetes1024.eqiad.wmnet with OS bullseye
17:03 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db1132', diff saved to https://phabricator.wikimedia.org/P35096 and previous config saved to /var/cache/conftool/dbconfig/20220928-170342-ladsgroup.json
16:59 ayounsi@cumin1001: END (PASS) - Cookbook sre.network.peering (exit_code=0) with action 'configure' for AS: 10310
16:58 cmjohnson@cumin1001: END (PASS) - Cookbook sre.hosts.provision (exit_code=0) for host kubernetes1024.mgmt.eqiad.wmnet with reboot policy FORCED
16:54 ayounsi@cumin1001: START - Cookbook sre.network.peering with action 'configure' for AS: 10310
16:48 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db1132', diff saved to https://phabricator.wikimedia.org/P35095 and previous config saved to /var/cache/conftool/dbconfig/20220928-164835-ladsgroup.json
16:33 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db1132 (T314041)', diff saved to https://phabricator.wikimedia.org/P35093 and previous config saved to /var/cache/conftool/dbconfig/20220928-163329-ladsgroup.json
16:33 cmjohnson@cumin1001: END (PASS) - Cookbook sre.dns.netbox (exit_code=0)
16:31 ayounsi@cumin1001: END (FAIL) - Cookbook sre.network.peering (exit_code=99) with action 'configure' for AS: 10310
15:51 nokafor@deploy1002: Started deploy [airflow-dags/analytics@0646be1]: (no justification provided)
15:47 btullis@cumin1001: START - Cookbook sre.druid.roll-restart-workers for Druid test cluster: Roll restart of Druid jvm daemons.
15:47 btullis@cumin1001: END (PASS) - Cookbook sre.druid.roll-restart-workers (exit_code=0) for Druid analytics cluster: Roll restart of Druid jvm daemons.
15:28 pt1979@cumin2002: END (PASS) - Cookbook sre.hosts.reimage (exit_code=0) for host logstash2036.codfw.wmnet with OS buster
15:26 moritzm: installing libgoogle-gson-java security updates on bullseye
15:20 pt1979@cumin2002: END (PASS) - Cookbook sre.dns.netbox (exit_code=0)
15:19 ayounsi@cumin1001: END (PASS) - Cookbook sre.network.peering (exit_code=0) with action 'configure' for AS: 4922
15:18 ayounsi@cumin1001: START - Cookbook sre.network.peering with action 'configure' for AS: 4922
15:15 ayounsi@cumin1001: END (PASS) - Cookbook sre.network.peering (exit_code=0) with action 'configure' for AS: 714
15:07 ayounsi@cumin1001: START - Cookbook sre.network.peering with action 'configure' for AS: 8674
15:02 ladsgroup@cumin1001: dbctl commit (dc=all): 'Depooling db2167:3311 (T314041)', diff saved to https://phabricator.wikimedia.org/P35092 and previous config saved to /var/cache/conftool/dbconfig/20220928-150230-ladsgroup.json
15:02 ladsgroup@cumin1001: END (PASS) - Cookbook sre.hosts.downtime (exit_code=0) for 1 day, 0:00:00 on db2167.codfw.wmnet with reason: Maintenance
15:02 ladsgroup@cumin1001: START - Cookbook sre.hosts.downtime for 1 day, 0:00:00 on db2167.codfw.wmnet with reason: Maintenance
15:01 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db2153 (T314041)', diff saved to https://phabricator.wikimedia.org/P35091 and previous config saved to /var/cache/conftool/dbconfig/20220928-150158-ladsgroup.json
15:01 btullis@cumin1001: START - Cookbook sre.druid.roll-restart-workers for Druid analytics cluster: Roll restart of Druid jvm daemons.
15:00 SandraEbele: deploying Airflow for hdfsarchiver operator fix
15:00 ebysans@deploy1002: Started deploy [airflow-dags/analytics@aa7984f]: (no justification provided)
14:59 cmjohnson@cumin1001: END (PASS) - Cookbook sre.hosts.reimage (exit_code=0) for host graphite1005.eqiad.wmnet with OS bullseye
14:55 andrew@cumin1001: END (PASS) - Cookbook sre.hosts.reboot-single (exit_code=0) for host cloudrabbit1003.wikimedia.org
14:53 btullis@cumin1001: END (PASS) - Cookbook sre.druid.roll-restart-workers (exit_code=0) for Druid public cluster: Roll restart of Druid jvm daemons.
14:52 ayounsi@cumin1001: END (PASS) - Cookbook sre.network.peering (exit_code=0) with action 'email' for AS: 394354
14:52 ayounsi@cumin1001: START - Cookbook sre.network.peering with action 'email' for AS: 394354
14:52 ayounsi@cumin1001: END (PASS) - Cookbook sre.network.peering (exit_code=0) with action 'email' for AS: 393950
14:51 ayounsi@cumin1001: START - Cookbook sre.network.peering with action 'email' for AS: 393950
14:51 ayounsi@cumin1001: END (PASS) - Cookbook sre.network.peering (exit_code=0) with action 'email' for AS: 262589
14:50 ayounsi@cumin1001: START - Cookbook sre.network.peering with action 'email' for AS: 262589
14:50 ayounsi@cumin1001: END (PASS) - Cookbook sre.network.peering (exit_code=0) with action 'email' for AS: 209453
14:50 ayounsi@cumin1001: START - Cookbook sre.network.peering with action 'email' for AS: 209453
14:50 ayounsi@cumin1001: END (PASS) - Cookbook sre.network.peering (exit_code=0) with action 'email' for AS: 199524
14:48 andrew@cumin1001: START - Cookbook sre.hosts.reboot-single for host cloudrabbit1003.wikimedia.org
14:48 ayounsi@cumin1001: START - Cookbook sre.network.peering with action 'email' for AS: 199524
14:48 ayounsi@cumin1001: END (FAIL) - Cookbook sre.network.peering (exit_code=99) with action 'email' for AS: 65517
14:48 ayounsi@cumin1001: START - Cookbook sre.network.peering with action 'email' for AS: 65517
14:48 ayounsi@cumin1001: END (PASS) - Cookbook sre.network.peering (exit_code=0) with action 'email' for AS: 62955
14:47 ayounsi@cumin1001: START - Cookbook sre.network.peering with action 'email' for AS: 62955
14:47 ayounsi@cumin1001: END (PASS) - Cookbook sre.network.peering (exit_code=0) with action 'email' for AS: 57695
14:47 ayounsi@cumin1001: START - Cookbook sre.network.peering with action 'email' for AS: 57695
14:47 ayounsi@cumin1001: END (PASS) - Cookbook sre.network.peering (exit_code=0) with action 'email' for AS: 53334
14:46 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db2153', diff saved to https://phabricator.wikimedia.org/P35090 and previous config saved to /var/cache/conftool/dbconfig/20220928-144651-ladsgroup.json
14:46 ayounsi@cumin1001: START - Cookbook sre.network.peering with action 'email' for AS: 53334
14:46 ayounsi@cumin1001: END (PASS) - Cookbook sre.network.peering (exit_code=0) with action 'email' for AS: 52320
14:45 ayounsi@cumin1001: START - Cookbook sre.network.peering with action 'email' for AS: 52320
14:45 ayounsi@cumin1001: END (PASS) - Cookbook sre.network.peering (exit_code=0) with action 'email' for AS: 46450
14:45 andrew@cumin1001: END (PASS) - Cookbook sre.hosts.reimage (exit_code=0) for host cloudrabbit1003.wikimedia.org with OS bullseye
14:45 cmjohnson@cumin1001: END (PASS) - Cookbook sre.hosts.downtime (exit_code=0) for 2:00:00 on graphite1005.eqiad.wmnet with reason: host reimage
14:45 ayounsi@cumin1001: START - Cookbook sre.network.peering with action 'email' for AS: 46450
14:45 ayounsi@cumin1001: END (PASS) - Cookbook sre.network.peering (exit_code=0) with action 'email' for AS: 40217
14:44 ayounsi@cumin1001: START - Cookbook sre.network.peering with action 'email' for AS: 40217
14:44 ayounsi@cumin1001: END (PASS) - Cookbook sre.network.peering (exit_code=0) with action 'email' for AS: 36692
14:44 pt1979@cumin2002: START - Cookbook sre.hosts.reimage for host logstash2036.codfw.wmnet with OS buster
14:43 ayounsi@cumin1001: START - Cookbook sre.network.peering with action 'email' for AS: 36692
14:43 ayounsi@cumin1001: END (PASS) - Cookbook sre.network.peering (exit_code=0) with action 'email' for AS: 36351
14:42 ayounsi@cumin1001: START - Cookbook sre.network.peering with action 'email' for AS: 36351
14:42 ayounsi@cumin1001: END (PASS) - Cookbook sre.network.peering (exit_code=0) with action 'email' for AS: 35280
14:41 cmjohnson@cumin1001: START - Cookbook sre.hosts.downtime for 2:00:00 on graphite1005.eqiad.wmnet with reason: host reimage
14:41 ayounsi@cumin1001: START - Cookbook sre.network.peering with action 'email' for AS: 35280
14:41 ayounsi@cumin1001: END (PASS) - Cookbook sre.network.peering (exit_code=0) with action 'email' for AS: 32934
14:39 ayounsi@cumin1001: START - Cookbook sre.network.peering with action 'email' for AS: 32934
14:39 ayounsi@cumin1001: END (PASS) - Cookbook sre.network.peering (exit_code=0) with action 'email' for AS: 32787
14:38 ayounsi@cumin1001: START - Cookbook sre.network.peering with action 'email' for AS: 32787
14:38 ayounsi@cumin1001: END (PASS) - Cookbook sre.network.peering (exit_code=0) with action 'email' for AS: 32098
14:36 ayounsi@cumin1001: START - Cookbook sre.network.peering with action 'email' for AS: 32098
14:36 ayounsi@cumin1001: END (PASS) - Cookbook sre.network.peering (exit_code=0) with action 'email' for AS: 29791
14:35 ayounsi@cumin1001: START - Cookbook sre.network.peering with action 'email' for AS: 29791
14:35 ayounsi@cumin1001: END (PASS) - Cookbook sre.network.peering (exit_code=0) with action 'email' for AS: 26744
14:34 ayounsi@cumin1001: START - Cookbook sre.network.peering with action 'email' for AS: 26744
14:34 ayounsi@cumin1001: END (PASS) - Cookbook sre.network.peering (exit_code=0) with action 'email' for AS: 25885
14:33 ayounsi@cumin1001: START - Cookbook sre.network.peering with action 'email' for AS: 25885
14:33 ayounsi@cumin1001: END (PASS) - Cookbook sre.network.peering (exit_code=0) with action 'email' for AS: 22987
14:31 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db2153', diff saved to https://phabricator.wikimedia.org/P35089 and previous config saved to /var/cache/conftool/dbconfig/20220928-143145-ladsgroup.json
14:31 ayounsi@cumin1001: START - Cookbook sre.network.peering with action 'email' for AS: 22987
14:30 ayounsi@cumin1001: END (PASS) - Cookbook sre.network.peering (exit_code=0) with action 'email' for AS: 22773
14:30 ayounsi@cumin1001: START - Cookbook sre.network.peering with action 'email' for AS: 22773
14:30 ayounsi@cumin1001: END (PASS) - Cookbook sre.network.peering (exit_code=0) with action 'email' for AS: 22616
14:29 ayounsi@cumin1001: START - Cookbook sre.network.peering with action 'email' for AS: 22616
14:29 ayounsi@cumin1001: END (PASS) - Cookbook sre.network.peering (exit_code=0) with action 'email' for AS: 21949
14:29 andrew@cumin1001: END (PASS) - Cookbook sre.hosts.downtime (exit_code=0) for 2:00:00 on cloudrabbit1003.wikimedia.org with reason: host reimage
14:29 cmjohnson@cumin1001: START - Cookbook sre.hosts.reimage for host graphite1005.eqiad.wmnet with OS bullseye
14:29 ayounsi@cumin1001: START - Cookbook sre.network.peering with action 'email' for AS: 21949
14:29 ayounsi@cumin1001: END (PASS) - Cookbook sre.network.peering (exit_code=0) with action 'email' for AS: 21928
14:28 ayounsi@cumin1001: START - Cookbook sre.network.peering with action 'email' for AS: 21928
14:28 ayounsi@cumin1001: END (PASS) - Cookbook sre.network.peering (exit_code=0) with action 'email' for AS: 20115
14:28 ayounsi@cumin1001: START - Cookbook sre.network.peering with action 'email' for AS: 20115
14:28 ayounsi@cumin1001: END (PASS) - Cookbook sre.network.peering (exit_code=0) with action 'email' for AS: 19653
14:27 ayounsi@cumin1001: START - Cookbook sre.network.peering with action 'email' for AS: 19653
14:27 ayounsi@cumin1001: END (PASS) - Cookbook sre.network.peering (exit_code=0) with action 'email' for AS: 19151
14:27 ayounsi@cumin1001: START - Cookbook sre.network.peering with action 'email' for AS: 19151
14:27 ayounsi@cumin1001: END (PASS) - Cookbook sre.network.peering (exit_code=0) with action 'email' for AS: 19108
14:26 andrew@cumin1001: START - Cookbook sre.hosts.downtime for 2:00:00 on cloudrabbit1003.wikimedia.org with reason: host reimage
14:26 ayounsi@cumin1001: START - Cookbook sre.network.peering with action 'email' for AS: 19108
14:26 ayounsi@cumin1001: END (PASS) - Cookbook sre.network.peering (exit_code=0) with action 'email' for AS: 18106
14:24 ayounsi@cumin1001: START - Cookbook sre.network.peering with action 'email' for AS: 18106
14:24 ayounsi@cumin1001: END (PASS) - Cookbook sre.network.peering (exit_code=0) with action 'email' for AS: 16735
14:24 ayounsi@cumin1001: START - Cookbook sre.network.peering with action 'email' for AS: 16735
14:24 ayounsi@cumin1001: END (PASS) - Cookbook sre.network.peering (exit_code=0) with action 'email' for AS: 16276
14:22 ayounsi@cumin1001: START - Cookbook sre.network.peering with action 'email' for AS: 16276
14:22 ayounsi@cumin1001: END (PASS) - Cookbook sre.network.peering (exit_code=0) with action 'email' for AS: 15695
14:22 ayounsi@cumin1001: START - Cookbook sre.network.peering with action 'email' for AS: 15695
14:21 ayounsi@cumin1001: END (PASS) - Cookbook sre.network.peering (exit_code=0) with action 'email' for AS: 15133
14:20 ayounsi@cumin1001: START - Cookbook sre.network.peering with action 'email' for AS: 15133
14:20 ayounsi@cumin1001: END (PASS) - Cookbook sre.network.peering (exit_code=0) with action 'email' for AS: 14630
14:19 ayounsi@cumin1001: START - Cookbook sre.network.peering with action 'email' for AS: 14630
14:19 ayounsi@cumin1001: END (PASS) - Cookbook sre.network.peering (exit_code=0) with action 'email' for AS: 14361
14:18 ayounsi@cumin1001: START - Cookbook sre.network.peering with action 'email' for AS: 14361
14:18 ayounsi@cumin1001: END (PASS) - Cookbook sre.network.peering (exit_code=0) with action 'email' for AS: 13760
14:18 ayounsi@cumin1001: START - Cookbook sre.network.peering with action 'email' for AS: 13760
14:18 ayounsi@cumin1001: END (PASS) - Cookbook sre.network.peering (exit_code=0) with action 'email' for AS: 13489
14:18 ayounsi@cumin1001: START - Cookbook sre.network.peering with action 'email' for AS: 13489
14:18 ayounsi@cumin1001: END (PASS) - Cookbook sre.network.peering (exit_code=0) with action 'email' for AS: 13335
14:16 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db2153 (T314041)', diff saved to https://phabricator.wikimedia.org/P35088 and previous config saved to /var/cache/conftool/dbconfig/20220928-141638-ladsgroup.json
14:16 cmjohnson@cumin1001: END (PASS) - Cookbook sre.hosts.provision (exit_code=0) for host graphite1005.mgmt.eqiad.wmnet with reboot policy FORCED
14:15 ayounsi@cumin1001: START - Cookbook sre.network.peering with action 'email' for AS: 13335
14:15 ayounsi@cumin1001: END (PASS) - Cookbook sre.network.peering (exit_code=0) with action 'email' for AS: 12200
14:15 ayounsi@cumin1001: START - Cookbook sre.network.peering with action 'email' for AS: 12200
14:15 ayounsi@cumin1001: END (PASS) - Cookbook sre.network.peering (exit_code=0) with action 'email' for AS: 12041
14:15 ayounsi@cumin1001: START - Cookbook sre.network.peering with action 'email' for AS: 12041
14:15 ayounsi@cumin1001: END (PASS) - Cookbook sre.network.peering (exit_code=0) with action 'email' for AS: 11164
14:14 ayounsi@cumin1001: START - Cookbook sre.network.peering with action 'email' for AS: 11164
14:14 ayounsi@cumin1001: END (PASS) - Cookbook sre.network.peering (exit_code=0) with action 'email' for AS: 11039
14:14 ayounsi@cumin1001: START - Cookbook sre.network.peering with action 'email' for AS: 11039
14:14 ayounsi@cumin1001: END (PASS) - Cookbook sre.network.peering (exit_code=0) with action 'email' for AS: 10310
14:12 volans: added python3-gjson v0.0.5 to apt.w.o (bullseye only)
14:12 ayounsi@cumin1001: START - Cookbook sre.network.peering with action 'email' for AS: 10310
14:11 ayounsi@cumin1001: END (PASS) - Cookbook sre.network.peering (exit_code=0) with action 'email' for AS: 8966
14:11 elukey@cumin1001: END (PASS) - Cookbook sre.ores.roll-restart-workers (exit_code=0) for ORES eqiad cluster: Roll restart of ORES's daemons.
14:11 ayounsi@cumin1001: START - Cookbook sre.network.peering with action 'email' for AS: 8966
14:11 ayounsi@cumin1001: END (PASS) - Cookbook sre.network.peering (exit_code=0) with action 'email' for AS: 8781
14:10 marostegui@cumin1001: dbctl commit (dc=all): 'es2022 (re)pooling @ 100%: After upgrade', diff saved to https://phabricator.wikimedia.org/P35087 and previous config saved to /var/cache/conftool/dbconfig/20220928-141007-root.json
14:10 marostegui@cumin1001: dbctl commit (dc=all): 'db2122 (re)pooling @ 100%: After upgrade', diff saved to https://phabricator.wikimedia.org/P35086 and previous config saved to /var/cache/conftool/dbconfig/20220928-141001-root.json
14:09 marostegui@cumin1001: dbctl commit (dc=all): 'db2146 (re)pooling @ 100%: After upgrade', diff saved to https://phabricator.wikimedia.org/P35085 and previous config saved to /var/cache/conftool/dbconfig/20220928-140956-root.json
14:09 ayounsi@cumin1001: START - Cookbook sre.network.peering with action 'email' for AS: 8781
14:09 ayounsi@cumin1001: END (PASS) - Cookbook sre.network.peering (exit_code=0) with action 'email' for AS: 8674
14:09 marostegui@cumin1001: dbctl commit (dc=all): 'db2180 (re)pooling @ 100%: After upgrade', diff saved to https://phabricator.wikimedia.org/P35084 and previous config saved to /var/cache/conftool/dbconfig/20220928-140950-root.json
14:09 jmm@cumin2002: END (PASS) - Cookbook sre.o11y.roll-restart-reboot-thanos-fe (exit_code=0) rolling restart_daemons on A:thanos-fe-eqiad
14:09 andrew@cumin1001: START - Cookbook sre.hosts.reimage for host cloudrabbit1003.wikimedia.org with OS bullseye
14:08 ayounsi@cumin1001: START - Cookbook sre.network.peering with action 'email' for AS: 8674
14:08 ayounsi@cumin1001: END (PASS) - Cookbook sre.network.peering (exit_code=0) with action 'email' for AS: 8359
14:08 andrew@cumin1001: END (ERROR) - Cookbook sre.hosts.reboot-single (exit_code=97) for host cloudrabbit1003.wikimedia.org
14:08 ayounsi@cumin1001: START - Cookbook sre.network.peering with action 'email' for AS: 8359
14:08 ayounsi@cumin1001: END (PASS) - Cookbook sre.network.peering (exit_code=0) with action 'email' for AS: 8075
14:08 jmm@cumin2002: START - Cookbook sre.o11y.roll-restart-reboot-thanos-fe rolling restart_daemons on A:thanos-fe-eqiad
14:06 ayounsi@cumin1001: START - Cookbook sre.network.peering with action 'email' for AS: 8075
14:06 ayounsi@cumin1001: END (PASS) - Cookbook sre.network.peering (exit_code=0) with action 'email' for AS: 7843
14:06 ayounsi@cumin1001: START - Cookbook sre.network.peering with action 'email' for AS: 7843
14:06 ayounsi@cumin1001: END (PASS) - Cookbook sre.network.peering (exit_code=0) with action 'email' for AS: 7795
14:06 ayounsi@cumin1001: START - Cookbook sre.network.peering with action 'email' for AS: 7795
14:06 ayounsi@cumin1001: END (PASS) - Cookbook sre.network.peering (exit_code=0) with action 'email' for AS: 7784
14:05 ayounsi@cumin1001: START - Cookbook sre.network.peering with action 'email' for AS: 7784
14:05 ayounsi@cumin1001: END (PASS) - Cookbook sre.network.peering (exit_code=0) with action 'email' for AS: 7713
14:04 ayounsi@cumin1001: START - Cookbook sre.network.peering with action 'email' for AS: 7713
14:04 ayounsi@cumin1001: END (PASS) - Cookbook sre.network.peering (exit_code=0) with action 'email' for AS: 7195
14:04 jmm@cumin2002: END (PASS) - Cookbook sre.o11y.roll-restart-reboot-thanos-fe (exit_code=0) rolling restart_daemons on A:thanos-fe-codfw
14:04 ayounsi@cumin1001: START - Cookbook sre.network.peering with action 'email' for AS: 7195
14:04 ayounsi@cumin1001: END (PASS) - Cookbook sre.network.peering (exit_code=0) with action 'email' for AS: 6762
14:03 cmjohnson@cumin1001: START - Cookbook sre.hosts.provision for host graphite1005.mgmt.eqiad.wmnet with reboot policy FORCED
14:03 ayounsi@cumin1001: START - Cookbook sre.network.peering with action 'email' for AS: 6762
14:03 ayounsi@cumin1001: END (PASS) - Cookbook sre.network.peering (exit_code=0) with action 'email' for AS: 6614
14:02 ayounsi@cumin1001: START - Cookbook sre.network.peering with action 'email' for AS: 6614
14:02 jmm@cumin2002: START - Cookbook sre.o11y.roll-restart-reboot-thanos-fe rolling restart_daemons on A:thanos-fe-codfw
14:02 ayounsi@cumin1001: END (PASS) - Cookbook sre.network.peering (exit_code=0) with action 'email' for AS: 6128
14:02 ayounsi@cumin1001: START - Cookbook sre.network.peering with action 'email' for AS: 6128
14:02 ayounsi@cumin1001: END (PASS) - Cookbook sre.network.peering (exit_code=0) with action 'email' for AS: 6079
14:01 btullis@cumin1001: START - Cookbook sre.druid.roll-restart-workers for Druid public cluster: Roll restart of Druid jvm daemons.
14:01 ayounsi@cumin1001: START - Cookbook sre.network.peering with action 'email' for AS: 6079
14:01 ayounsi@cumin1001: END (PASS) - Cookbook sre.network.peering (exit_code=0) with action 'email' for AS: 5650
14:00 ayounsi@cumin1001: START - Cookbook sre.network.peering with action 'email' for AS: 5650
14:00 ayounsi@cumin1001: END (PASS) - Cookbook sre.network.peering (exit_code=0) with action 'email' for AS: 5400
14:00 ayounsi@cumin1001: START - Cookbook sre.network.peering with action 'email' for AS: 5400
14:00 ayounsi@cumin1001: END (PASS) - Cookbook sre.network.peering (exit_code=0) with action 'email' for AS: 4922
13:59 ayounsi@cumin1001: START - Cookbook sre.network.peering with action 'email' for AS: 4922
13:59 ayounsi@cumin1001: END (PASS) - Cookbook sre.network.peering (exit_code=0) with action 'email' for AS: 4826
13:59 ayounsi@cumin1001: START - Cookbook sre.network.peering with action 'email' for AS: 4826
13:59 ayounsi@cumin1001: END (PASS) - Cookbook sre.network.peering (exit_code=0) with action 'email' for AS: 4775
13:57 ayounsi@cumin1001: START - Cookbook sre.network.peering with action 'email' for AS: 4775
13:57 ayounsi@cumin1001: END (PASS) - Cookbook sre.network.peering (exit_code=0) with action 'email' for AS: 4637
13:56 ayounsi@cumin1001: START - Cookbook sre.network.peering with action 'email' for AS: 4637
13:56 ayounsi@cumin1001: END (PASS) - Cookbook sre.network.peering (exit_code=0) with action 'email' for AS: 4230
13:56 ayounsi@cumin1001: START - Cookbook sre.network.peering with action 'email' for AS: 4230
13:55 ayounsi@cumin1001: END (PASS) - Cookbook sre.network.peering (exit_code=0) with action 'email' for AS: 4181
13:55 ayounsi@cumin1001: START - Cookbook sre.network.peering with action 'email' for AS: 4181
13:55 ayounsi@cumin1001: END (PASS) - Cookbook sre.network.peering (exit_code=0) with action 'email' for AS: 3856
13:55 marostegui@cumin1001: dbctl commit (dc=all): 'es2022 (re)pooling @ 75%: After upgrade', diff saved to https://phabricator.wikimedia.org/P35083 and previous config saved to /var/cache/conftool/dbconfig/20220928-135502-root.json
13:54 marostegui@cumin1001: dbctl commit (dc=all): 'db2122 (re)pooling @ 75%: After upgrade', diff saved to https://phabricator.wikimedia.org/P35082 and previous config saved to /var/cache/conftool/dbconfig/20220928-135456-root.json
13:54 marostegui@cumin1001: dbctl commit (dc=all): 'db2146 (re)pooling @ 75%: After upgrade', diff saved to https://phabricator.wikimedia.org/P35081 and previous config saved to /var/cache/conftool/dbconfig/20220928-135451-root.json
13:54 marostegui@cumin1001: dbctl commit (dc=all): 'db2180 (re)pooling @ 75%: After upgrade', diff saved to https://phabricator.wikimedia.org/P35080 and previous config saved to /var/cache/conftool/dbconfig/20220928-135445-root.json
13:53 ayounsi@cumin1001: START - Cookbook sre.network.peering with action 'email' for AS: 3856
13:53 ayounsi@cumin1001: END (PASS) - Cookbook sre.network.peering (exit_code=0) with action 'email' for AS: 3300
13:53 cmjohnson@cumin1001: END (PASS) - Cookbook sre.dns.netbox (exit_code=0)
13:52 elukey@cumin1001: START - Cookbook sre.ores.roll-restart-workers for ORES eqiad cluster: Roll restart of ORES's daemons.
13:50 ayounsi@cumin1001: START - Cookbook sre.network.peering with action 'email' for AS: 3300
13:50 ayounsi@cumin1001: END (PASS) - Cookbook sre.network.peering (exit_code=0) with action 'email' for AS: 3292
13:50 elukey@cumin1001: END (PASS) - Cookbook sre.ores.roll-restart-workers (exit_code=0) for ORES codfw cluster: Roll restart of ORES's daemons.
13:50 ayounsi@cumin1001: START - Cookbook sre.network.peering with action 'email' for AS: 3292
13:50 ayounsi@cumin1001: END (PASS) - Cookbook sre.network.peering (exit_code=0) with action 'email' for AS: 2906
13:49 andrew@cumin1001: START - Cookbook sre.hosts.reboot-single for host cloudrabbit1003.wikimedia.org
13:48 ayounsi@cumin1001: START - Cookbook sre.network.peering with action 'email' for AS: 2906
13:48 ayounsi@cumin1001: END (PASS) - Cookbook sre.network.peering (exit_code=0) with action 'email' for AS: 2647
13:47 ayounsi@cumin1001: START - Cookbook sre.network.peering with action 'email' for AS: 2647
13:47 ayounsi@cumin1001: END (PASS) - Cookbook sre.network.peering (exit_code=0) with action 'email' for AS: 2635
13:46 ayounsi@cumin1001: START - Cookbook sre.network.peering with action 'email' for AS: 2635
13:46 ayounsi@cumin1001: END (PASS) - Cookbook sre.network.peering (exit_code=0) with action 'email' for AS: 2603
13:46 ayounsi@cumin1001: START - Cookbook sre.network.peering with action 'email' for AS: 2603
13:45 ayounsi@cumin1001: END (PASS) - Cookbook sre.network.peering (exit_code=0) with action 'email' for AS: 1273
13:45 ayounsi@cumin1001: START - Cookbook sre.network.peering with action 'email' for AS: 1273
13:45 ayounsi@cumin1001: END (PASS) - Cookbook sre.network.peering (exit_code=0) with action 'email' for AS: 812
13:44 ayounsi@cumin1001: START - Cookbook sre.network.peering with action 'email' for AS: 812
13:44 ayounsi@cumin1001: END (PASS) - Cookbook sre.network.peering (exit_code=0) with action 'email' for AS: 714
13:42 ayounsi@cumin1001: START - Cookbook sre.network.peering with action 'email' for AS: 714
13:39 marostegui@cumin1001: dbctl commit (dc=all): 'es2022 (re)pooling @ 50%: After upgrade', diff saved to https://phabricator.wikimedia.org/P35079 and previous config saved to /var/cache/conftool/dbconfig/20220928-133957-root.json
13:39 marostegui@cumin1001: dbctl commit (dc=all): 'db2122 (re)pooling @ 50%: After upgrade', diff saved to https://phabricator.wikimedia.org/P35078 and previous config saved to /var/cache/conftool/dbconfig/20220928-133951-root.json
13:39 marostegui@cumin1001: dbctl commit (dc=all): 'db2146 (re)pooling @ 50%: After upgrade', diff saved to https://phabricator.wikimedia.org/P35077 and previous config saved to /var/cache/conftool/dbconfig/20220928-133946-root.json
13:39 marostegui@cumin1001: dbctl commit (dc=all): 'db2180 (re)pooling @ 50%: After upgrade', diff saved to https://phabricator.wikimedia.org/P35076 and previous config saved to /var/cache/conftool/dbconfig/20220928-133940-root.json
13:34 jmm@cumin2002: END (FAIL) - Cookbook sre.o11y.roll-restart-reboot-thanos-fe (exit_code=1) rolling restart_daemons on A:thanos-fe-codfw
13:33 btullis@cumin1001: END (PASS) - Cookbook sre.kafka.roll-restart-mirror-maker (exit_code=0) restart MirrorMaker for Kafka A:kafka-mirror-maker-jumbo-eqiad cluster: Roll restart of jvm daemons.
13:33 ayounsi@cumin1001: END (PASS) - Cookbook sre.network.peering (exit_code=0) with action 'email' for AS: 577
13:32 jmm@cumin2002: START - Cookbook sre.o11y.roll-restart-reboot-thanos-fe rolling restart_daemons on A:thanos-fe-codfw
13:32 ayounsi@cumin1001: START - Cookbook sre.network.peering with action 'email' for AS: 577
13:31 ayounsi@cumin1001: END (PASS) - Cookbook sre.network.peering (exit_code=0) with action 'email' for AS: 42
13:31 elukey@cumin1001: START - Cookbook sre.ores.roll-restart-workers for ORES codfw cluster: Roll restart of ORES's daemons.
13:30 ayounsi@cumin1001: START - Cookbook sre.network.peering with action 'email' for AS: 42
13:24 marostegui@cumin1001: dbctl commit (dc=all): 'es2022 (re)pooling @ 25%: After upgrade', diff saved to https://phabricator.wikimedia.org/P35075 and previous config saved to /var/cache/conftool/dbconfig/20220928-132452-root.json
13:24 marostegui@cumin1001: dbctl commit (dc=all): 'db2122 (re)pooling @ 25%: After upgrade', diff saved to https://phabricator.wikimedia.org/P35074 and previous config saved to /var/cache/conftool/dbconfig/20220928-132446-root.json
13:24 marostegui@cumin1001: dbctl commit (dc=all): 'db2146 (re)pooling @ 25%: After upgrade', diff saved to https://phabricator.wikimedia.org/P35073 and previous config saved to /var/cache/conftool/dbconfig/20220928-132442-root.json
13:24 marostegui@cumin1001: dbctl commit (dc=all): 'db2180 (re)pooling @ 25%: After upgrade', diff saved to https://phabricator.wikimedia.org/P35072 and previous config saved to /var/cache/conftool/dbconfig/20220928-132435-root.json
13:19 elukey@deploy1002: helmfile [ml-serve-eqiad] Ran 'sync' command on namespace 'revscoring-editquality-reverted' for release 'main' .
13:17 elukey@deploy1002: helmfile [ml-serve-eqiad] Ran 'sync' command on namespace 'revscoring-editquality-goodfaith' for release 'main' .
13:15 btullis@cumin1001: START - Cookbook sre.kafka.roll-restart-mirror-maker restart MirrorMaker for Kafka A:kafka-mirror-maker-jumbo-eqiad cluster: Roll restart of jvm daemons.
13:09 marostegui@cumin1001: dbctl commit (dc=all): 'es2022 (re)pooling @ 10%: After upgrade', diff saved to https://phabricator.wikimedia.org/P35071 and previous config saved to /var/cache/conftool/dbconfig/20220928-130947-root.json
13:09 marostegui@cumin1001: dbctl commit (dc=all): 'db2122 (re)pooling @ 10%: After upgrade', diff saved to https://phabricator.wikimedia.org/P35070 and previous config saved to /var/cache/conftool/dbconfig/20220928-130941-root.json
13:09 marostegui@cumin1001: dbctl commit (dc=all): 'db2146 (re)pooling @ 10%: After upgrade', diff saved to https://phabricator.wikimedia.org/P35069 and previous config saved to /var/cache/conftool/dbconfig/20220928-130937-root.json
13:09 marostegui@cumin1001: dbctl commit (dc=all): 'db2180 (re)pooling @ 10%: After upgrade', diff saved to https://phabricator.wikimedia.org/P35068 and previous config saved to /var/cache/conftool/dbconfig/20220928-130930-root.json
13:06 elukey@deploy1002: helmfile [ml-serve-eqiad] Ran 'sync' command on namespace 'revscoring-editquality-damaging' for release 'main' .
13:05 elukey@deploy1002: helmfile [ml-serve-eqiad] Ran 'sync' command on namespace 'revscoring-drafttopic' for release 'main' .
13:04 elukey@deploy1002: helmfile [ml-serve-eqiad] Ran 'sync' command on namespace 'revscoring-draftquality' for release 'main' .
13:04 elukey@deploy1002: helmfile [ml-serve-eqiad] Ran 'sync' command on namespace 'revscoring-articletopic' for release 'main' .
13:03 elukey@deploy1002: helmfile [ml-serve-eqiad] Ran 'sync' command on namespace 'revscoring-articlequality' for release 'main' .
13:02 elukey@deploy1002: helmfile [ml-serve-eqiad] Ran 'sync' command on namespace 'articletopic-outlink' for release 'main' .
13:01 elukey@deploy1002: helmfile [ml-serve-eqiad] Ran 'sync' command on namespace 'experimental' for release 'main' .
12:54 marostegui@cumin1001: dbctl commit (dc=all): 'es2022 (re)pooling @ 5%: After upgrade', diff saved to https://phabricator.wikimedia.org/P35067 and previous config saved to /var/cache/conftool/dbconfig/20220928-125442-root.json
12:54 marostegui@cumin1001: dbctl commit (dc=all): 'db2122 (re)pooling @ 5%: After upgrade', diff saved to https://phabricator.wikimedia.org/P35066 and previous config saved to /var/cache/conftool/dbconfig/20220928-125436-root.json
12:54 marostegui@cumin1001: dbctl commit (dc=all): 'db2146 (re)pooling @ 5%: After upgrade', diff saved to https://phabricator.wikimedia.org/P35065 and previous config saved to /var/cache/conftool/dbconfig/20220928-125432-root.json
12:54 marostegui@cumin1001: dbctl commit (dc=all): 'db2180 (re)pooling @ 5%: After upgrade', diff saved to https://phabricator.wikimedia.org/P35064 and previous config saved to /var/cache/conftool/dbconfig/20220928-125425-root.json
12:39 marostegui@cumin1001: dbctl commit (dc=all): 'es2022 (re)pooling @ 3%: After upgrade', diff saved to https://phabricator.wikimedia.org/P35063 and previous config saved to /var/cache/conftool/dbconfig/20220928-123937-root.json
12:39 marostegui@cumin1001: dbctl commit (dc=all): 'db2122 (re)pooling @ 3%: After upgrade', diff saved to https://phabricator.wikimedia.org/P35062 and previous config saved to /var/cache/conftool/dbconfig/20220928-123932-root.json
12:39 marostegui@cumin1001: dbctl commit (dc=all): 'db2146 (re)pooling @ 3%: After upgrade', diff saved to https://phabricator.wikimedia.org/P35061 and previous config saved to /var/cache/conftool/dbconfig/20220928-123927-root.json
12:39 marostegui@cumin1001: dbctl commit (dc=all): 'db2180 (re)pooling @ 3%: After upgrade', diff saved to https://phabricator.wikimedia.org/P35060 and previous config saved to /var/cache/conftool/dbconfig/20220928-123920-root.json
12:34 btullis@cumin1001: END (PASS) - Cookbook sre.kafka.roll-restart-brokers (exit_code=0) for Kafka A:kafka-jumbo-eqiad cluster: Roll restart of jvm daemons.
12:24 marostegui@cumin1001: dbctl commit (dc=all): 'es2022 (re)pooling @ 1%: After upgrade', diff saved to https://phabricator.wikimedia.org/P35058 and previous config saved to /var/cache/conftool/dbconfig/20220928-122432-root.json
12:24 marostegui@cumin1001: dbctl commit (dc=all): 'db2122 (re)pooling @ 1%: After upgrade', diff saved to https://phabricator.wikimedia.org/P35057 and previous config saved to /var/cache/conftool/dbconfig/20220928-122427-root.json
12:24 gehel: copying wmf-elasticsearh-search-plugins from bullseye to buster (`reprepro -C thirdparty/elastic710 copy buster-wikimedia bullseye-wikimedia wmf-elasticsearch-search-plugins`)
12:24 marostegui@cumin1001: dbctl commit (dc=all): 'db2146 (re)pooling @ 1%: After upgrade', diff saved to https://phabricator.wikimedia.org/P35056 and previous config saved to /var/cache/conftool/dbconfig/20220928-122422-root.json
12:24 marostegui@cumin1001: dbctl commit (dc=all): 'es1022 (re)pooling @ 100%: After upgrade', diff saved to https://phabricator.wikimedia.org/P35055 and previous config saved to /var/cache/conftool/dbconfig/20220928-122421-root.json
12:24 marostegui@cumin1001: dbctl commit (dc=all): 'db2180 (re)pooling @ 1%: After upgrade', diff saved to https://phabricator.wikimedia.org/P35054 and previous config saved to /var/cache/conftool/dbconfig/20220928-122415-root.json
12:24 marostegui@cumin1001: dbctl commit (dc=all): 'db1127 (re)pooling @ 100%: After upgrade', diff saved to https://phabricator.wikimedia.org/P35053 and previous config saved to /var/cache/conftool/dbconfig/20220928-122414-root.json
12:24 marostegui@cumin1001: dbctl commit (dc=all): 'db1132 (re)pooling @ 100%: After upgrade', diff saved to https://phabricator.wikimedia.org/P35052 and previous config saved to /var/cache/conftool/dbconfig/20220928-122411-root.json
12:24 marostegui@cumin1001: dbctl commit (dc=all): 'db1143 (re)pooling @ 100%: After upgrade', diff saved to https://phabricator.wikimedia.org/P35051 and previous config saved to /var/cache/conftool/dbconfig/20220928-122403-root.json
12:23 marostegui@cumin1001: dbctl commit (dc=all): 'db1168 (re)pooling @ 100%: After upgrade', diff saved to https://phabricator.wikimedia.org/P35050 and previous config saved to /var/cache/conftool/dbconfig/20220928-122356-root.json
12:23 marostegui@cumin1001: dbctl commit (dc=all): 'db1137 (re)pooling @ 100%: After upgrade', diff saved to https://phabricator.wikimedia.org/P35049 and previous config saved to /var/cache/conftool/dbconfig/20220928-122350-root.json
12:23 marostegui@cumin1001: dbctl commit (dc=all): 'db1111 (re)pooling @ 100%: After upgrade', diff saved to https://phabricator.wikimedia.org/P35048 and previous config saved to /var/cache/conftool/dbconfig/20220928-122346-root.json
12:23 marostegui@cumin1001: dbctl commit (dc=all): 'Depool db1132', diff saved to https://phabricator.wikimedia.org/P35047 and previous config saved to /var/cache/conftool/dbconfig/20220928-122321-root.json
12:22 gehel: above reprepro copy failed, elastic710 component does not exist yet
12:21 XioNoX: re-enable Init7 in knams
12:21 gehel: copying wmf-elasticsearh-search-plugins from bullseye to buster (`reprepro -C elastic710 buster-wikimedia bullseye-wikimedia wmf-elasticsearch-search-plugins`)
12:19 marostegui@cumin1001: dbctl commit (dc=all): 'Depool db2180 db2146 db2122 es2022 for mariadb upgrade T318128', diff saved to https://phabricator.wikimedia.org/P35046 and previous config saved to /var/cache/conftool/dbconfig/20220928-121912-root.json
12:11 jmm@cumin2002: END (PASS) - Cookbook sre.wdqs.restart-nginx (exit_code=0) rolling restart_daemons on A:wcqs-public
12:09 jmm@cumin2002: START - Cookbook sre.wdqs.restart-nginx rolling restart_daemons on A:wcqs-public
12:09 marostegui@cumin1001: dbctl commit (dc=all): 'es1022 (re)pooling @ 75%: After upgrade', diff saved to https://phabricator.wikimedia.org/P35045 and previous config saved to /var/cache/conftool/dbconfig/20220928-120916-root.json
12:09 marostegui@cumin1001: dbctl commit (dc=all): 'db1127 (re)pooling @ 75%: After upgrade', diff saved to https://phabricator.wikimedia.org/P35044 and previous config saved to /var/cache/conftool/dbconfig/20220928-120909-root.json
12:09 marostegui@cumin1001: dbctl commit (dc=all): 'db1132 (re)pooling @ 75%: After upgrade', diff saved to https://phabricator.wikimedia.org/P35043 and previous config saved to /var/cache/conftool/dbconfig/20220928-120906-root.json
12:08 marostegui@cumin1001: dbctl commit (dc=all): 'db1143 (re)pooling @ 75%: After upgrade', diff saved to https://phabricator.wikimedia.org/P35042 and previous config saved to /var/cache/conftool/dbconfig/20220928-120858-root.json
12:08 marostegui@cumin1001: dbctl commit (dc=all): 'db1168 (re)pooling @ 75%: After upgrade', diff saved to https://phabricator.wikimedia.org/P35041 and previous config saved to /var/cache/conftool/dbconfig/20220928-120852-root.json
12:08 marostegui@cumin1001: dbctl commit (dc=all): 'db1137 (re)pooling @ 75%: After upgrade', diff saved to https://phabricator.wikimedia.org/P35040 and previous config saved to /var/cache/conftool/dbconfig/20220928-120845-root.json
12:08 marostegui@cumin1001: dbctl commit (dc=all): 'db1111 (re)pooling @ 75%: After upgrade', diff saved to https://phabricator.wikimedia.org/P35039 and previous config saved to /var/cache/conftool/dbconfig/20220928-120841-root.json
12:08 jmm@cumin2002: END (PASS) - Cookbook sre.wdqs.restart-nginx (exit_code=0) rolling restart_daemons on A:wdqs-all
11:58 jmm@cumin2002: START - Cookbook sre.wdqs.restart-nginx rolling restart_daemons on A:wdqs-all
11:54 marostegui@cumin1001: dbctl commit (dc=all): 'es1022 (re)pooling @ 50%: After upgrade', diff saved to https://phabricator.wikimedia.org/P35038 and previous config saved to /var/cache/conftool/dbconfig/20220928-115411-root.json
11:54 marostegui@cumin1001: dbctl commit (dc=all): 'db1127 (re)pooling @ 50%: After upgrade', diff saved to https://phabricator.wikimedia.org/P35037 and previous config saved to /var/cache/conftool/dbconfig/20220928-115404-root.json
11:54 marostegui@cumin1001: dbctl commit (dc=all): 'db1132 (re)pooling @ 50%: After upgrade', diff saved to https://phabricator.wikimedia.org/P35036 and previous config saved to /var/cache/conftool/dbconfig/20220928-115401-root.json
11:53 marostegui@cumin1001: dbctl commit (dc=all): 'db1143 (re)pooling @ 50%: After upgrade', diff saved to https://phabricator.wikimedia.org/P35035 and previous config saved to /var/cache/conftool/dbconfig/20220928-115354-root.json
11:53 marostegui@cumin1001: dbctl commit (dc=all): 'db1168 (re)pooling @ 50%: After upgrade', diff saved to https://phabricator.wikimedia.org/P35034 and previous config saved to /var/cache/conftool/dbconfig/20220928-115347-root.json
11:53 marostegui@cumin1001: dbctl commit (dc=all): 'db1137 (re)pooling @ 50%: After upgrade', diff saved to https://phabricator.wikimedia.org/P35033 and previous config saved to /var/cache/conftool/dbconfig/20220928-115340-root.json
11:53 marostegui@cumin1001: dbctl commit (dc=all): 'db1111 (re)pooling @ 50%: After upgrade', diff saved to https://phabricator.wikimedia.org/P35032 and previous config saved to /var/cache/conftool/dbconfig/20220928-115336-root.json
11:39 marostegui@cumin1001: dbctl commit (dc=all): 'es1022 (re)pooling @ 25%: After upgrade', diff saved to https://phabricator.wikimedia.org/P35031 and previous config saved to /var/cache/conftool/dbconfig/20220928-113906-root.json
11:39 marostegui@cumin1001: dbctl commit (dc=all): 'db1127 (re)pooling @ 25%: After upgrade', diff saved to https://phabricator.wikimedia.org/P35030 and previous config saved to /var/cache/conftool/dbconfig/20220928-113900-root.json
11:38 marostegui@cumin1001: dbctl commit (dc=all): 'db1132 (re)pooling @ 25%: After upgrade', diff saved to https://phabricator.wikimedia.org/P35029 and previous config saved to /var/cache/conftool/dbconfig/20220928-113856-root.json
11:38 marostegui@cumin1001: dbctl commit (dc=all): 'db1143 (re)pooling @ 25%: After upgrade', diff saved to https://phabricator.wikimedia.org/P35028 and previous config saved to /var/cache/conftool/dbconfig/20220928-113849-root.json
11:38 marostegui@cumin1001: dbctl commit (dc=all): 'db1168 (re)pooling @ 25%: After upgrade', diff saved to https://phabricator.wikimedia.org/P35027 and previous config saved to /var/cache/conftool/dbconfig/20220928-113842-root.json
11:38 marostegui@cumin1001: dbctl commit (dc=all): 'db1137 (re)pooling @ 25%: After upgrade', diff saved to https://phabricator.wikimedia.org/P35026 and previous config saved to /var/cache/conftool/dbconfig/20220928-113835-root.json
11:38 marostegui@cumin1001: dbctl commit (dc=all): 'db1111 (re)pooling @ 25%: After upgrade', diff saved to https://phabricator.wikimedia.org/P35025 and previous config saved to /var/cache/conftool/dbconfig/20220928-113831-root.json
11:24 marostegui@cumin1001: dbctl commit (dc=all): 'es1022 (re)pooling @ 10%: After upgrade', diff saved to https://phabricator.wikimedia.org/P35024 and previous config saved to /var/cache/conftool/dbconfig/20220928-112401-root.json
11:23 marostegui@cumin1001: dbctl commit (dc=all): 'db1127 (re)pooling @ 10%: After upgrade', diff saved to https://phabricator.wikimedia.org/P35023 and previous config saved to /var/cache/conftool/dbconfig/20220928-112355-root.json
11:23 marostegui@cumin1001: dbctl commit (dc=all): 'db1132 (re)pooling @ 10%: After upgrade', diff saved to https://phabricator.wikimedia.org/P35022 and previous config saved to /var/cache/conftool/dbconfig/20220928-112351-root.json
11:23 marostegui@cumin1001: dbctl commit (dc=all): 'db1143 (re)pooling @ 10%: After upgrade', diff saved to https://phabricator.wikimedia.org/P35021 and previous config saved to /var/cache/conftool/dbconfig/20220928-112344-root.json
11:23 marostegui@cumin1001: dbctl commit (dc=all): 'db1168 (re)pooling @ 10%: After upgrade', diff saved to https://phabricator.wikimedia.org/P35020 and previous config saved to /var/cache/conftool/dbconfig/20220928-112337-root.json
11:23 marostegui@cumin1001: dbctl commit (dc=all): 'db1137 (re)pooling @ 10%: After upgrade', diff saved to https://phabricator.wikimedia.org/P35019 and previous config saved to /var/cache/conftool/dbconfig/20220928-112330-root.json
11:23 marostegui@cumin1001: dbctl commit (dc=all): 'db1111 (re)pooling @ 10%: After upgrade', diff saved to https://phabricator.wikimedia.org/P35018 and previous config saved to /var/cache/conftool/dbconfig/20220928-112326-root.json
11:18 moritzm: installing expat security updates
11:08 marostegui@cumin1001: dbctl commit (dc=all): 'es1022 (re)pooling @ 5%: After upgrade', diff saved to https://phabricator.wikimedia.org/P35017 and previous config saved to /var/cache/conftool/dbconfig/20220928-110856-root.json
11:08 marostegui@cumin1001: dbctl commit (dc=all): 'db1127 (re)pooling @ 5%: After upgrade', diff saved to https://phabricator.wikimedia.org/P35016 and previous config saved to /var/cache/conftool/dbconfig/20220928-110850-root.json
11:08 marostegui@cumin1001: dbctl commit (dc=all): 'db1132 (re)pooling @ 5%: After upgrade', diff saved to https://phabricator.wikimedia.org/P35015 and previous config saved to /var/cache/conftool/dbconfig/20220928-110846-root.json
11:08 marostegui@cumin1001: dbctl commit (dc=all): 'db1143 (re)pooling @ 5%: After upgrade', diff saved to https://phabricator.wikimedia.org/P35014 and previous config saved to /var/cache/conftool/dbconfig/20220928-110839-root.json
11:08 marostegui@cumin1001: dbctl commit (dc=all): 'db1168 (re)pooling @ 5%: After upgrade', diff saved to https://phabricator.wikimedia.org/P35013 and previous config saved to /var/cache/conftool/dbconfig/20220928-110832-root.json
11:08 marostegui@cumin1001: dbctl commit (dc=all): 'db1137 (re)pooling @ 5%: After upgrade', diff saved to https://phabricator.wikimedia.org/P35012 and previous config saved to /var/cache/conftool/dbconfig/20220928-110825-root.json
11:08 marostegui@cumin1001: dbctl commit (dc=all): 'db1111 (re)pooling @ 5%: After upgrade', diff saved to https://phabricator.wikimedia.org/P35011 and previous config saved to /var/cache/conftool/dbconfig/20220928-110821-root.json
10:55 ladsgroup@cumin1001: dbctl commit (dc=all): 'Depooling db1132 (T314041)', diff saved to https://phabricator.wikimedia.org/P35010 and previous config saved to /var/cache/conftool/dbconfig/20220928-105531-ladsgroup.json
10:55 ladsgroup@cumin1001: END (PASS) - Cookbook sre.hosts.downtime (exit_code=0) for 1 day, 0:00:00 on db1132.eqiad.wmnet with reason: Maintenance
10:55 ladsgroup@cumin1001: START - Cookbook sre.hosts.downtime for 1 day, 0:00:00 on db1132.eqiad.wmnet with reason: Maintenance
10:55 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db1128 (T314041)', diff saved to https://phabricator.wikimedia.org/P35009 and previous config saved to /var/cache/conftool/dbconfig/20220928-105520-ladsgroup.json
10:53 marostegui@cumin1001: dbctl commit (dc=all): 'es1022 (re)pooling @ 3%: After upgrade', diff saved to https://phabricator.wikimedia.org/P35008 and previous config saved to /var/cache/conftool/dbconfig/20220928-105351-root.json
10:53 marostegui@cumin1001: dbctl commit (dc=all): 'db1127 (re)pooling @ 3%: After upgrade', diff saved to https://phabricator.wikimedia.org/P35007 and previous config saved to /var/cache/conftool/dbconfig/20220928-105345-root.json
10:53 marostegui@cumin1001: dbctl commit (dc=all): 'db1132 (re)pooling @ 3%: After upgrade', diff saved to https://phabricator.wikimedia.org/P35006 and previous config saved to /var/cache/conftool/dbconfig/20220928-105340-root.json
10:53 marostegui@cumin1001: dbctl commit (dc=all): 'db1143 (re)pooling @ 3%: After upgrade', diff saved to https://phabricator.wikimedia.org/P35005 and previous config saved to /var/cache/conftool/dbconfig/20220928-105332-root.json
10:53 marostegui@cumin1001: dbctl commit (dc=all): 'db1168 (re)pooling @ 3%: After upgrade', diff saved to https://phabricator.wikimedia.org/P35004 and previous config saved to /var/cache/conftool/dbconfig/20220928-105327-root.json
10:53 marostegui@cumin1001: dbctl commit (dc=all): 'db1137 (re)pooling @ 3%: After upgrade', diff saved to https://phabricator.wikimedia.org/P35003 and previous config saved to /var/cache/conftool/dbconfig/20220928-105320-root.json
10:53 marostegui@cumin1001: dbctl commit (dc=all): 'db1111 (re)pooling @ 3%: After upgrade', diff saved to https://phabricator.wikimedia.org/P35002 and previous config saved to /var/cache/conftool/dbconfig/20220928-105315-root.json
10:40 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db1128', diff saved to https://phabricator.wikimedia.org/P35001 and previous config saved to /var/cache/conftool/dbconfig/20220928-104014-ladsgroup.json
10:38 marostegui@cumin1001: dbctl commit (dc=all): 'es1022 (re)pooling @ 1%: After upgrade', diff saved to https://phabricator.wikimedia.org/P35000 and previous config saved to /var/cache/conftool/dbconfig/20220928-103847-root.json
10:38 marostegui@cumin1001: dbctl commit (dc=all): 'db1127 (re)pooling @ 1%: After upgrade', diff saved to https://phabricator.wikimedia.org/P34999 and previous config saved to /var/cache/conftool/dbconfig/20220928-103840-root.json
10:38 marostegui@cumin1001: dbctl commit (dc=all): 'db1132 (re)pooling @ 1%: After upgrade', diff saved to https://phabricator.wikimedia.org/P34998 and previous config saved to /var/cache/conftool/dbconfig/20220928-103835-root.json
10:38 marostegui@cumin1001: dbctl commit (dc=all): 'db1143 (re)pooling @ 1%: After upgrade', diff saved to https://phabricator.wikimedia.org/P34997 and previous config saved to /var/cache/conftool/dbconfig/20220928-103827-root.json
10:38 marostegui@cumin1001: dbctl commit (dc=all): 'db1168 (re)pooling @ 1%: After upgrade', diff saved to https://phabricator.wikimedia.org/P34996 and previous config saved to /var/cache/conftool/dbconfig/20220928-103822-root.json
10:38 marostegui@cumin1001: dbctl commit (dc=all): 'db1137 (re)pooling @ 1%: After upgrade', diff saved to https://phabricator.wikimedia.org/P34995 and previous config saved to /var/cache/conftool/dbconfig/20220928-103815-root.json
10:38 marostegui@cumin1001: dbctl commit (dc=all): 'db1111 (re)pooling @ 1%: After upgrade', diff saved to https://phabricator.wikimedia.org/P34994 and previous config saved to /var/cache/conftool/dbconfig/20220928-103810-root.json
10:30 elukey@deploy1002: helmfile [ml-serve-codfw] Ran 'sync' command on namespace 'revscoring-editquality-reverted' for release 'main' .
10:28 elukey@deploy1002: helmfile [ml-serve-codfw] Ran 'sync' command on namespace 'revscoring-editquality-goodfaith' for release 'main' .
10:28 marostegui@cumin1001: dbctl commit (dc=all): 'Depool db1111 db1137 db1168 db1143 db1132 db1127 es1022 for mariadb upgrade T318128', diff saved to https://phabricator.wikimedia.org/P34993 and previous config saved to /var/cache/conftool/dbconfig/20220928-102759-root.json
10:25 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db1128', diff saved to https://phabricator.wikimedia.org/P34992 and previous config saved to /var/cache/conftool/dbconfig/20220928-102508-ladsgroup.json
10:19 elukey@deploy1002: helmfile [ml-serve-codfw] Ran 'sync' command on namespace 'revscoring-editquality-damaging' for release 'main' .
10:18 elukey@deploy1002: helmfile [ml-serve-codfw] Ran 'sync' command on namespace 'revscoring-drafttopic' for release 'main' .
10:17 elukey@deploy1002: helmfile [ml-serve-codfw] Ran 'sync' command on namespace 'revscoring-draftquality' for release 'main' .
10:15 elukey@deploy1002: helmfile [ml-serve-codfw] Ran 'sync' command on namespace 'revscoring-articletopic' for release 'main' .
10:13 elukey@deploy1002: helmfile [ml-serve-codfw] Ran 'sync' command on namespace 'articletopic-outlink' for release 'main' .
10:12 elukey@deploy1002: helmfile [ml-serve-codfw] Ran 'sync' command on namespace 'experimental' for release 'main' .
10:11 elukey@deploy1002: helmfile [ml-serve-codfw] Ran 'sync' command on namespace 'revscoring-articlequality' for release 'main' .
10:10 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db1128 (T314041)', diff saved to https://phabricator.wikimedia.org/P34990 and previous config saved to /var/cache/conftool/dbconfig/20220928-101001-ladsgroup.json
08:45 ladsgroup@cumin1001: dbctl commit (dc=all): 'Depooling db2153 (T314041)', diff saved to https://phabricator.wikimedia.org/P34989 and previous config saved to /var/cache/conftool/dbconfig/20220928-084557-ladsgroup.json
08:45 ladsgroup@cumin1001: END (PASS) - Cookbook sre.hosts.downtime (exit_code=0) for 1 day, 0:00:00 on db2153.codfw.wmnet with reason: Maintenance
08:45 ladsgroup@cumin1001: START - Cookbook sre.hosts.downtime for 1 day, 0:00:00 on db2153.codfw.wmnet with reason: Maintenance
08:45 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db2146 (T314041)', diff saved to https://phabricator.wikimedia.org/P34988 and previous config saved to /var/cache/conftool/dbconfig/20220928-084535-ladsgroup.json
08:40 elukey@deploy1002: helmfile [ml-staging-codfw] Ran 'sync' command on namespace 'revscoring-editquality-reverted' for release 'main' .
08:40 elukey@deploy1002: helmfile [ml-staging-codfw] Ran 'sync' command on namespace 'revscoring-editquality-goodfaith' for release 'main' .
08:39 elukey@deploy1002: helmfile [ml-staging-codfw] Ran 'sync' command on namespace 'revscoring-editquality-damaging' for release 'main' .
08:38 elukey@deploy1002: helmfile [ml-staging-codfw] Ran 'sync' command on namespace 'revscoring-drafttopic' for release 'main' .
08:37 elukey@deploy1002: helmfile [ml-staging-codfw] Ran 'sync' command on namespace 'revscoring-draftquality' for release 'main' .
08:36 elukey@deploy1002: helmfile [ml-staging-codfw] Ran 'sync' command on namespace 'revscoring-articletopic' for release 'main' .
08:35 elukey@deploy1002: helmfile [ml-staging-codfw] Ran 'sync' command on namespace 'revscoring-articlequality' for release 'main' .
08:34 elukey@deploy1002: helmfile [ml-staging-codfw] Ran 'sync' command on namespace 'experimental' for release 'main' .
08:30 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db2146', diff saved to https://phabricator.wikimedia.org/P34987 and previous config saved to /var/cache/conftool/dbconfig/20220928-083029-ladsgroup.json
08:29 elukey@deploy1002: helmfile [ml-staging-codfw] Ran 'sync' command on namespace 'articletopic-outlink' for release 'main' .
08:15 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db2146', diff saved to https://phabricator.wikimedia.org/P34985 and previous config saved to /var/cache/conftool/dbconfig/20220928-081522-ladsgroup.json
08:00 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db2146 (T314041)', diff saved to https://phabricator.wikimedia.org/P34984 and previous config saved to /var/cache/conftool/dbconfig/20220928-080015-ladsgroup.json
04:37 ladsgroup@cumin1001: dbctl commit (dc=all): 'Depooling db1128 (T314041)', diff saved to https://phabricator.wikimedia.org/P34981 and previous config saved to /var/cache/conftool/dbconfig/20220928-043052-ladsgroup.json
04:34 ladsgroup@cumin1001: END (PASS) - Cookbook sre.hosts.downtime (exit_code=0) for 1 day, 0:00:00 on db1128.eqiad.wmnet with reason: Maintenance
04:32 ladsgroup@cumin1001: START - Cookbook sre.hosts.downtime for 1 day, 0:00:00 on db1128.eqiad.wmnet with reason: Maintenance
04:30 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db1119 (T314041)', diff saved to https://phabricator.wikimedia.org/P34980 and previous config saved to /var/cache/conftool/dbconfig/20220928-043030-ladsgroup.json
04:15 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db1119', diff saved to https://phabricator.wikimedia.org/P34979 and previous config saved to /var/cache/conftool/dbconfig/20220928-041524-ladsgroup.json
04:00 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db1119', diff saved to https://phabricator.wikimedia.org/P34978 and previous config saved to /var/cache/conftool/dbconfig/20220928-040017-ladsgroup.json
03:45 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db1119 (T314041)', diff saved to https://phabricator.wikimedia.org/P34977 and previous config saved to /var/cache/conftool/dbconfig/20220928-034511-ladsgroup.json
02:14 ladsgroup@cumin1001: dbctl commit (dc=all): 'Depooling db2146 (T314041)', diff saved to https://phabricator.wikimedia.org/P34976 and previous config saved to /var/cache/conftool/dbconfig/20220928-020746-ladsgroup.json
02:11 ladsgroup@cumin1001: END (PASS) - Cookbook sre.hosts.downtime (exit_code=0) for 1 day, 0:00:00 on db2146.codfw.wmnet with reason: Maintenance
02:09 ladsgroup@cumin1001: START - Cookbook sre.hosts.downtime for 1 day, 0:00:00 on db2146.codfw.wmnet with reason: Maintenance
02:07 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db2145 (T314041)', diff saved to https://phabricator.wikimedia.org/P34975 and previous config saved to /var/cache/conftool/dbconfig/20220928-020724-ladsgroup.json
01:52 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db2145', diff saved to https://phabricator.wikimedia.org/P34974 and previous config saved to /var/cache/conftool/dbconfig/20220928-015218-ladsgroup.json
01:37 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db2145', diff saved to https://phabricator.wikimedia.org/P34973 and previous config saved to /var/cache/conftool/dbconfig/20220928-013711-ladsgroup.json
01:22 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db2145 (T314041)', diff saved to https://phabricator.wikimedia.org/P34972 and previous config saved to /var/cache/conftool/dbconfig/20220928-012205-ladsgroup.json
01:18 ejegg: updated fundraising python tools from b65109af to dd494413
22:16 cmjohnson@cumin1001: END (PASS) - Cookbook sre.hosts.reimage (exit_code=0) for host mc-wf1002.eqiad.wmnet with OS bullseye
22:13 cmjohnson@cumin1001: END (PASS) - Cookbook sre.hosts.reimage (exit_code=0) for host mc-wf1001.eqiad.wmnet with OS bullseye
22:02 cmjohnson@cumin1001: END (PASS) - Cookbook sre.hosts.downtime (exit_code=0) for 2:00:00 on mc-wf1002.eqiad.wmnet with reason: host reimage
21:58 cmjohnson@cumin1001: END (PASS) - Cookbook sre.hosts.downtime (exit_code=0) for 2:00:00 on mc-wf1001.eqiad.wmnet with reason: host reimage
21:58 cmjohnson@cumin1001: START - Cookbook sre.hosts.downtime for 2:00:00 on mc-wf1002.eqiad.wmnet with reason: host reimage
21:55 cmjohnson@cumin1001: START - Cookbook sre.hosts.downtime for 2:00:00 on mc-wf1001.eqiad.wmnet with reason: host reimage
21:47 cmjohnson@cumin1001: START - Cookbook sre.hosts.reimage for host mc-wf1002.eqiad.wmnet with OS bullseye
21:44 cmjohnson@cumin1001: START - Cookbook sre.hosts.reimage for host mc-wf1001.eqiad.wmnet with OS bullseye
21:30 ladsgroup@cumin1001: dbctl commit (dc=all): 'Depooling db1119 (T314041)', diff saved to https://phabricator.wikimedia.org/P34971 and previous config saved to /var/cache/conftool/dbconfig/20220927-213028-ladsgroup.json
21:30 ladsgroup@cumin1001: END (PASS) - Cookbook sre.hosts.downtime (exit_code=0) for 1 day, 0:00:00 on db1119.eqiad.wmnet with reason: Maintenance
21:30 ladsgroup@cumin1001: START - Cookbook sre.hosts.downtime for 1 day, 0:00:00 on db1119.eqiad.wmnet with reason: Maintenance
21:30 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db1118 (T314041)', diff saved to https://phabricator.wikimedia.org/P34970 and previous config saved to /var/cache/conftool/dbconfig/20220927-213006-ladsgroup.json
21:15 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db1118', diff saved to https://phabricator.wikimedia.org/P34969 and previous config saved to /var/cache/conftool/dbconfig/20220927-211500-ladsgroup.json
21:06 samtar@deploy1002: samtar and ssastry: Backport for Remove figures from text extracts (T318727) synced to the testservers: mwdebug2002.codfw.wmnet, mwdebug1002.eqiad.wmnet, mwdebug1001.eqiad.wmnet, mwdebug2001.codfw.wmnet
20:59 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db1118', diff saved to https://phabricator.wikimedia.org/P34968 and previous config saved to /var/cache/conftool/dbconfig/20220927-205953-ladsgroup.json
20:59 TheresNoTime: extending UTC late backport window
20:58 cmjohnson@cumin1001: END (PASS) - Cookbook sre.hosts.provision (exit_code=0) for host mc-wf1001.mgmt.eqiad.wmnet with reboot policy FORCED
20:58 cmjohnson@cumin1001: END (PASS) - Cookbook sre.hosts.provision (exit_code=0) for host mc-wf1002.mgmt.eqiad.wmnet with reboot policy FORCED
20:58 samtar@deploy1002: samtar and ssastry: Backport for Remove figures from text extracts (T318727) synced to the testservers: mwdebug1001.eqiad.wmnet, mwdebug2001.codfw.wmnet, mwdebug1002.eqiad.wmnet, mwdebug2002.codfw.wmnet
20:48 samtar@deploy1002: samtar and stang: Backport for romdwikimedia: Enable subpages in NS0 (T318491) synced to the testservers: mwdebug2001.codfw.wmnet, mwdebug2002.codfw.wmnet, mwdebug1001.eqiad.wmnet, mwdebug1002.eqiad.wmnet
20:45 cmjohnson@cumin1001: START - Cookbook sre.hosts.provision for host mc-wf1002.mgmt.eqiad.wmnet with reboot policy FORCED
20:45 cmjohnson@cumin1001: START - Cookbook sre.hosts.provision for host mc-wf1001.mgmt.eqiad.wmnet with reboot policy FORCED
20:44 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db1118 (T314041)', diff saved to https://phabricator.wikimedia.org/P34967 and previous config saved to /var/cache/conftool/dbconfig/20220927-204446-ladsgroup.json
20:33 samtar@deploy1002: samtar and kemayo: Backport for Add wmgMFDefaultEditor back in for future use synced to the testservers: mwdebug1001.eqiad.wmnet, mwdebug2001.codfw.wmnet, mwdebug2002.codfw.wmnet, mwdebug1002.eqiad.wmnet
20:04 samtar@deploy1002: samtar and kemayo: Backport for MobileWebUIActions sample rate to 1 on testwiki (T302108) synced to the testservers: mwdebug2002.codfw.wmnet, mwdebug2001.codfw.wmnet, mwdebug1002.eqiad.wmnet, mwdebug1001.eqiad.wmnet
14:56 mforns@deploy1002: Started deploy [airflow-dags/analytics@25dda27]: (no justification provided)
14:38 ladsgroup@cumin1001: END (PASS) - Cookbook sre.hosts.downtime (exit_code=0) for 1 day, 0:00:00 on db2141.codfw.wmnet with reason: Maintenance
14:38 ladsgroup@cumin1001: START - Cookbook sre.hosts.downtime for 1 day, 0:00:00 on db2141.codfw.wmnet with reason: Maintenance
14:38 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db2130 (T314041)', diff saved to https://phabricator.wikimedia.org/P34958 and previous config saved to /var/cache/conftool/dbconfig/20220927-143831-ladsgroup.json
14:35 pt1979@cumin2002: END (ERROR) - Cookbook sre.hosts.reimage (exit_code=97) for host logstash2036.codfw.wmnet with OS buster
14:31 ladsgroup@cumin1001: dbctl commit (dc=all): 'Depooling db1118 (T314041)', diff saved to https://phabricator.wikimedia.org/P34957 and previous config saved to /var/cache/conftool/dbconfig/20220927-143109-ladsgroup.json
14:31 ladsgroup@cumin1001: END (PASS) - Cookbook sre.hosts.downtime (exit_code=0) for 1 day, 0:00:00 on db1118.eqiad.wmnet with reason: Maintenance
14:30 ladsgroup@cumin1001: START - Cookbook sre.hosts.downtime for 1 day, 0:00:00 on db1118.eqiad.wmnet with reason: Maintenance
14:30 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db1107 (T314041)', diff saved to https://phabricator.wikimedia.org/P34956 and previous config saved to /var/cache/conftool/dbconfig/20220927-143047-ladsgroup.json
14:26 pt1979@cumin2002: START - Cookbook sre.hosts.reimage for host logstash2036.codfw.wmnet with OS buster
14:23 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db2130', diff saved to https://phabricator.wikimedia.org/P34955 and previous config saved to /var/cache/conftool/dbconfig/20220927-142324-ladsgroup.json
14:15 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db1107', diff saved to https://phabricator.wikimedia.org/P34954 and previous config saved to /var/cache/conftool/dbconfig/20220927-141541-ladsgroup.json
14:08 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db2130', diff saved to https://phabricator.wikimedia.org/P34953 and previous config saved to /var/cache/conftool/dbconfig/20220927-140817-ladsgroup.json
14:00 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db1107', diff saved to https://phabricator.wikimedia.org/P34952 and previous config saved to /var/cache/conftool/dbconfig/20220927-140034-ladsgroup.json
13:53 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db2130 (T314041)', diff saved to https://phabricator.wikimedia.org/P34951 and previous config saved to /var/cache/conftool/dbconfig/20220927-135310-ladsgroup.json
13:45 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db1107 (T314041)', diff saved to https://phabricator.wikimedia.org/P34950 and previous config saved to /var/cache/conftool/dbconfig/20220927-134528-ladsgroup.json
12:42 klausman@deploy1002: helmfile [ml-serve-codfw] Ran 'sync' command on namespace 'revscoring-editquality-reverted' for release 'main' .
12:36 klausman@deploy1002: helmfile [ml-serve-codfw] Ran 'sync' command on namespace 'revscoring-editquality-goodfaith' for release 'main' .
12:31 klausman@deploy1002: helmfile [ml-serve-codfw] Ran 'sync' command on namespace 'revscoring-editquality-damaging' for release 'main' .
12:28 klausman@deploy1002: helmfile [ml-serve-codfw] Ran 'sync' command on namespace 'revscoring-drafttopic' for release 'main' .
12:26 klausman@deploy1002: helmfile [ml-serve-codfw] Ran 'sync' command on namespace 'revscoring-draftquality' for release 'main' .
12:23 klausman@deploy1002: helmfile [ml-serve-codfw] Ran 'sync' command on namespace 'revscoring-articletopic' for release 'main' .
12:20 klausman@deploy1002: helmfile [ml-serve-codfw] Ran 'sync' command on namespace 'revscoring-articlequality' for release 'main' .
12:18 klausman@deploy1002: helmfile [ml-serve-codfw] Ran 'sync' command on namespace 'experimental' for release 'main' .
12:15 klausman@deploy1002: helmfile [ml-serve-codfw] Ran 'sync' command on namespace 'articletopic-outlink' for release 'main' .
10:10 mvernon@cumin1001: END (FAIL) - Cookbook sre.hosts.decommission (exit_code=99) for hosts ms-be[1028-1033,1035-1039].eqiad.wmnet
10:06 mvernon@cumin1001: START - Cookbook sre.hosts.decommission for hosts ms-be[1028-1033,1035-1039].eqiad.wmnet
10:03 moritzm: rebalance ganeti/codfw row D after completed Bullseye update T311686
09:14 volans@cumin2002: START - Cookbook sre.hosts.provision for host logstash2037.mgmt.codfw.wmnet with reboot policy FORCED
09:13 volans@cumin2002: END (ERROR) - Cookbook sre.hosts.provision (exit_code=97) for host logstash2037.mgmt.codfw.wmnet with reboot policy FORCED
09:12 volans@cumin2002: START - Cookbook sre.hosts.provision for host logstash2037.mgmt.codfw.wmnet with reboot policy FORCED
08:20 ladsgroup@cumin1001: dbctl commit (dc=all): 'Depooling db2130 (T314041)', diff saved to https://phabricator.wikimedia.org/P34942 and previous config saved to /var/cache/conftool/dbconfig/20220927-082023-ladsgroup.json
08:20 ladsgroup@cumin1001: END (PASS) - Cookbook sre.hosts.downtime (exit_code=0) for 1 day, 0:00:00 on db2130.codfw.wmnet with reason: Maintenance
08:20 ladsgroup@cumin1001: START - Cookbook sre.hosts.downtime for 1 day, 0:00:00 on db2130.codfw.wmnet with reason: Maintenance
08:20 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db2116 (T314041)', diff saved to https://phabricator.wikimedia.org/P34941 and previous config saved to /var/cache/conftool/dbconfig/20220927-082001-ladsgroup.json
08:15 moritzm: restarting apache/FPM on mw canaries to pick up Expat security updates
08:04 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db2116', diff saved to https://phabricator.wikimedia.org/P34938 and previous config saved to /var/cache/conftool/dbconfig/20220927-080454-ladsgroup.json
08:00 jmm@cumin2002: END (PASS) - Cookbook sre.misc-clusters.thumbor (exit_code=0) rolling restart_daemons on A:thumbor-eqiad
07:58 jmm@cumin2002: START - Cookbook sre.misc-clusters.thumbor rolling restart_daemons on A:thumbor-eqiad
07:57 jmm@cumin2002: END (PASS) - Cookbook sre.misc-clusters.thumbor (exit_code=0) rolling restart_daemons on A:thumbor-codfw
07:54 jmm@cumin2002: START - Cookbook sre.misc-clusters.thumbor rolling restart_daemons on A:thumbor-codfw
07:52 XioNoX: upgrade python3-pynetbox to 6.6.0 on cumin1001 - T310745
07:49 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db2116', diff saved to https://phabricator.wikimedia.org/P34937 and previous config saved to /var/cache/conftool/dbconfig/20220927-074948-ladsgroup.json
07:49 XioNoX: upgrade python3-pynetbox to 6.6.0 on cumin2002 - T310745
07:48 moritzm: installing expat security updates on stretch/buster/bullseye
07:39 moritzm: uploaded expat 2.2.0-2+deb9u5+wmf1 to apt.wikimedia.org/stretch-wikimedia
07:36 jayme: published image docker-registry.discovery.wmnet/golang1.18:1.18-1
07:35 ladsgroup@cumin1001: dbctl commit (dc=all): 'Depooling db1107 (T314041)', diff saved to https://phabricator.wikimedia.org/P34936 and previous config saved to /var/cache/conftool/dbconfig/20220927-073523-ladsgroup.json
07:35 ladsgroup@cumin1001: END (PASS) - Cookbook sre.hosts.downtime (exit_code=0) for 1 day, 0:00:00 on db1107.eqiad.wmnet with reason: Maintenance
07:34 ladsgroup@cumin1001: START - Cookbook sre.hosts.downtime for 1 day, 0:00:00 on db1107.eqiad.wmnet with reason: Maintenance
07:34 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db1106 (T314041)', diff saved to https://phabricator.wikimedia.org/P34935 and previous config saved to /var/cache/conftool/dbconfig/20220927-073451-ladsgroup.json
07:34 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db2116 (T314041)', diff saved to https://phabricator.wikimedia.org/P34934 and previous config saved to /var/cache/conftool/dbconfig/20220927-073441-ladsgroup.json
07:19 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db1106', diff saved to https://phabricator.wikimedia.org/P34933 and previous config saved to /var/cache/conftool/dbconfig/20220927-071938-ladsgroup.json
07:04 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db1106', diff saved to https://phabricator.wikimedia.org/P34932 and previous config saved to /var/cache/conftool/dbconfig/20220927-070431-ladsgroup.json
06:59 ayounsi@cumin1001: END (PASS) - Cookbook sre.network.peering (exit_code=0) with action 'show' for AS: 8220
06:58 ayounsi@cumin1001: START - Cookbook sre.network.peering with action 'show' for AS: 8220
06:49 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db1106 (T314041)', diff saved to https://phabricator.wikimedia.org/P34930 and previous config saved to /var/cache/conftool/dbconfig/20220927-064925-ladsgroup.json
05:28 marostegui: Install 10.6.10 on db1124, db1125, pc1014, pc2014 T318128
02:01 ladsgroup@cumin1001: dbctl commit (dc=all): 'Depooling db2116 (T314041)', diff saved to https://phabricator.wikimedia.org/P34928 and previous config saved to /var/cache/conftool/dbconfig/20220927-020124-ladsgroup.json
02:01 ladsgroup@cumin1001: END (PASS) - Cookbook sre.hosts.downtime (exit_code=0) for 1 day, 0:00:00 on db2116.codfw.wmnet with reason: Maintenance
02:01 ladsgroup@cumin1001: START - Cookbook sre.hosts.downtime for 1 day, 0:00:00 on db2116.codfw.wmnet with reason: Maintenance
02:01 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db2103 (T314041)', diff saved to https://phabricator.wikimedia.org/P34927 and previous config saved to /var/cache/conftool/dbconfig/20220927-020103-ladsgroup.json
01:45 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db2103', diff saved to https://phabricator.wikimedia.org/P34926 and previous config saved to /var/cache/conftool/dbconfig/20220927-014556-ladsgroup.json
01:30 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db2103', diff saved to https://phabricator.wikimedia.org/P34925 and previous config saved to /var/cache/conftool/dbconfig/20220927-013050-ladsgroup.json
01:15 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db2103 (T314041)', diff saved to https://phabricator.wikimedia.org/P34924 and previous config saved to /var/cache/conftool/dbconfig/20220927-011543-ladsgroup.json
00:50 andrew@cumin1001: END (PASS) - Cookbook sre.hosts.reboot-single (exit_code=0) for host cloudcontrol1007.wikimedia.org
00:42 andrew@cumin1001: END (FAIL) - Cookbook sre.hosts.reboot-single (exit_code=1) for host cloudcontrol1006.wikimedia.org
00:40 andrew@cumin1001: START - Cookbook sre.hosts.reboot-single for host cloudcontrol1007.wikimedia.org
00:32 andrew@cumin1001: END (FAIL) - Cookbook sre.hosts.reboot-single (exit_code=1) for host cloudcontrol1005.wikimedia.org
00:31 andrew@cumin1001: START - Cookbook sre.hosts.reboot-single for host cloudcontrol1006.wikimedia.org
00:16 andrew@cumin1001: START - Cookbook sre.hosts.reboot-single for host cloudcontrol1005.wikimedia.org
00:15 andrew@cumin1001: END (FAIL) - Cookbook sre.hosts.reboot-single (exit_code=99) for host cloudnet1005.eqiad.wmnet
00:15 andrew@cumin1001: START - Cookbook sre.hosts.reboot-single for host cloudnet1005.eqiad.wmnet
00:13 andrew@cumin1001: END (FAIL) - Cookbook sre.hosts.reboot-single (exit_code=99) for host cloudnet1005.eqiad.wmnet
00:13 andrew@cumin1001: START - Cookbook sre.hosts.reboot-single for host cloudnet1005.eqiad.wmnet
00:05 ladsgroup@cumin1001: dbctl commit (dc=all): 'Depooling db1106 (T314041)', diff saved to https://phabricator.wikimedia.org/P34923 and previous config saved to /var/cache/conftool/dbconfig/20220927-000525-ladsgroup.json
00:05 ladsgroup@cumin1001: END (PASS) - Cookbook sre.hosts.downtime (exit_code=0) for 2 days, 0:00:00 on clouddb[1013,1017,1021].eqiad.wmnet,db1154.eqiad.wmnet with reason: Maintenance
00:04 andrew@cumin1001: END (PASS) - Cookbook sre.hosts.reboot-single (exit_code=0) for host cloudservices1005.wikimedia.org
00:04 ladsgroup@cumin1001: START - Cookbook sre.hosts.downtime for 2 days, 0:00:00 on clouddb[1013,1017,1021].eqiad.wmnet,db1154.eqiad.wmnet with reason: Maintenance
00:04 ladsgroup@cumin1001: END (PASS) - Cookbook sre.hosts.downtime (exit_code=0) for 1 day, 0:00:00 on db1106.eqiad.wmnet with reason: Maintenance
00:04 ladsgroup@cumin1001: START - Cookbook sre.hosts.downtime for 1 day, 0:00:00 on db1106.eqiad.wmnet with reason: Maintenance
00:04 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db1105:3311 (T314041)', diff saved to https://phabricator.wikimedia.org/P34922 and previous config saved to /var/cache/conftool/dbconfig/20220927-000434-ladsgroup.json
2022-09-26
23:56 andrew@cumin1001: START - Cookbook sre.hosts.reboot-single for host cloudservices1005.wikimedia.org
23:49 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db1105:3311', diff saved to https://phabricator.wikimedia.org/P34921 and previous config saved to /var/cache/conftool/dbconfig/20220926-234928-ladsgroup.json
23:34 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db1105:3311', diff saved to https://phabricator.wikimedia.org/P34920 and previous config saved to /var/cache/conftool/dbconfig/20220926-233422-ladsgroup.json
23:34 andrew@cumin1001: END (FAIL) - Cookbook sre.hosts.reboot-single (exit_code=1) for host cloudservices1004.wikimedia.org
23:21 andrew@cumin1001: START - Cookbook sre.hosts.reboot-single for host cloudservices1004.wikimedia.org
23:19 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db1105:3311 (T314041)', diff saved to https://phabricator.wikimedia.org/P34919 and previous config saved to /var/cache/conftool/dbconfig/20220926-231915-ladsgroup.json
23:14 pt1979@cumin2002: END (PASS) - Cookbook sre.hosts.reimage (exit_code=0) for host ganeti2032.codfw.wmnet with OS bullseye
22:59 pt1979@cumin2002: END (PASS) - Cookbook sre.hosts.downtime (exit_code=0) for 2:00:00 on ganeti2032.codfw.wmnet with reason: host reimage
22:56 pt1979@cumin2002: START - Cookbook sre.hosts.downtime for 2:00:00 on ganeti2032.codfw.wmnet with reason: host reimage
22:37 pt1979@cumin2002: START - Cookbook sre.hosts.reimage for host ganeti2032.codfw.wmnet with OS bullseye
22:33 pt1979@cumin2002: END (PASS) - Cookbook sre.hosts.reimage (exit_code=0) for host ganeti2031.codfw.wmnet with OS bullseye
22:18 pt1979@cumin2002: END (PASS) - Cookbook sre.hosts.downtime (exit_code=0) for 2:00:00 on ganeti2031.codfw.wmnet with reason: host reimage
22:14 pt1979@cumin2002: START - Cookbook sre.hosts.downtime for 2:00:00 on ganeti2031.codfw.wmnet with reason: host reimage
21:39 pt1979@cumin2002: START - Cookbook sre.hosts.reimage for host ganeti2031.codfw.wmnet with OS bullseye
21:06 cmjohnson@cumin1001: END (PASS) - Cookbook sre.hosts.provision (exit_code=0) for host centrallog1002.mgmt.eqiad.wmnet with reboot policy FORCED
20:41 cmjohnson@cumin1001: START - Cookbook sre.hosts.provision for host centrallog1002.mgmt.eqiad.wmnet with reboot policy FORCED
20:39 cmjohnson@cumin1001: END (PASS) - Cookbook sre.dns.netbox (exit_code=0)
17:10 pt1979@cumin2002: END (PASS) - Cookbook sre.network.configure-switch-interfaces (exit_code=0) for host logstash2037
17:09 pt1979@cumin2002: END (FAIL) - Cookbook sre.hosts.provision (exit_code=99) for host ganeti2031.mgmt.codfw.wmnet with reboot policy FORCED
17:08 pt1979@cumin2002: START - Cookbook sre.network.configure-switch-interfaces for host logstash2037
17:08 pt1979@cumin2002: END (PASS) - Cookbook sre.network.configure-switch-interfaces (exit_code=0) for host logstash2036
17:07 pt1979@cumin2002: START - Cookbook sre.network.configure-switch-interfaces for host logstash2036
17:07 pt1979@cumin2002: END (PASS) - Cookbook sre.dns.netbox (exit_code=0)
17:07 pt1979@cumin2002: START - Cookbook sre.hosts.provision for host ganeti2031.mgmt.codfw.wmnet with reboot policy FORCED
17:05 pt1979@cumin2002: END (PASS) - Cookbook sre.hosts.provision (exit_code=0) for host db2184.mgmt.codfw.wmnet with reboot policy FORCED
17:02 ladsgroup@cumin1001: dbctl commit (dc=all): 'Depooling db1105:3311 (T314041)', diff saved to https://phabricator.wikimedia.org/P34914 and previous config saved to /var/cache/conftool/dbconfig/20220926-170213-ladsgroup.json
17:02 ladsgroup@cumin1001: END (PASS) - Cookbook sre.hosts.downtime (exit_code=0) for 1 day, 0:00:00 on db1105.eqiad.wmnet with reason: Maintenance
17:01 ladsgroup@cumin1001: START - Cookbook sre.hosts.downtime for 1 day, 0:00:00 on db1105.eqiad.wmnet with reason: Maintenance
17:01 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db1099:3311 (T314041)', diff saved to https://phabricator.wikimedia.org/P34913 and previous config saved to /var/cache/conftool/dbconfig/20220926-170151-ladsgroup.json
16:56 pt1979@cumin2002: END (PASS) - Cookbook sre.network.configure-switch-interfaces (exit_code=0) for host ganeti2032
16:56 pt1979@cumin2002: START - Cookbook sre.network.configure-switch-interfaces for host ganeti2032
16:55 pt1979@cumin2002: END (PASS) - Cookbook sre.network.configure-switch-interfaces (exit_code=0) for host ganeti2031
16:55 pt1979@cumin2002: START - Cookbook sre.network.configure-switch-interfaces for host ganeti2031
16:52 pt1979@cumin2002: START - Cookbook sre.hosts.provision for host db2184.mgmt.codfw.wmnet with reboot policy FORCED
16:46 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db1099:3311', diff saved to https://phabricator.wikimedia.org/P34912 and previous config saved to /var/cache/conftool/dbconfig/20220926-164645-ladsgroup.json
16:35 pt1979@cumin2002: END (PASS) - Cookbook sre.hosts.provision (exit_code=0) for host db2183.mgmt.codfw.wmnet with reboot policy FORCED
16:31 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db1099:3311', diff saved to https://phabricator.wikimedia.org/P34911 and previous config saved to /var/cache/conftool/dbconfig/20220926-163138-ladsgroup.json
16:26 volans@cumin2002: END (FAIL) - Cookbook sre.hosts.provision (exit_code=99) for host db2184.mgmt.codfw.wmnet with reboot policy FORCED
16:25 volans@cumin2002: START - Cookbook sre.hosts.provision for host db2184.mgmt.codfw.wmnet with reboot policy FORCED
16:23 ladsgroup@cumin1001: dbctl commit (dc=all): 'db1166 (re)pooling @ 100%: Maint Done', diff saved to https://phabricator.wikimedia.org/P34910 and previous config saved to /var/cache/conftool/dbconfig/20220926-162322-ladsgroup.json
16:22 pt1979@cumin2002: START - Cookbook sre.hosts.provision for host db2183.mgmt.codfw.wmnet with reboot policy FORCED
16:16 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db1099:3311 (T314041)', diff saved to https://phabricator.wikimedia.org/P34909 and previous config saved to /var/cache/conftool/dbconfig/20220926-161632-ladsgroup.json
16:15 volans@cumin2002: END (FAIL) - Cookbook sre.hosts.provision (exit_code=99) for host db2183.mgmt.codfw.wmnet with reboot policy FORCED
16:08 ladsgroup@cumin1001: dbctl commit (dc=all): 'db1166 (re)pooling @ 75%: Maint Done', diff saved to https://phabricator.wikimedia.org/P34908 and previous config saved to /var/cache/conftool/dbconfig/20220926-160817-ladsgroup.json
16:04 volans@cumin2002: START - Cookbook sre.hosts.provision for host db2183.mgmt.codfw.wmnet with reboot policy FORCED
16:03 volans@cumin2002: END (FAIL) - Cookbook sre.hosts.provision (exit_code=99) for host db2183.mgmt.codfw.wmnet with reboot policy FORCED
15:58 elukey@deploy1002: helmfile [ml-staging-codfw] Ran 'sync' command on namespace 'articletopic-outlink' for release 'main' .
15:57 elukey@deploy1002: helmfile [ml-staging-codfw] Ran 'sync' command on namespace 'experimental' for release 'main' .
15:57 elukey@deploy1002: helmfile [ml-staging-codfw] Ran 'sync' command on namespace 'revscoring-drafttopic' for release 'main' .
15:55 elukey@deploy1002: helmfile [ml-staging-codfw] Ran 'sync' command on namespace 'revscoring-draftquality' for release 'main' .
15:54 elukey@deploy1002: helmfile [ml-staging-codfw] Ran 'sync' command on namespace 'revscoring-articletopic' for release 'main' .
15:53 elukey@deploy1002: helmfile [ml-staging-codfw] Ran 'sync' command on namespace 'revscoring-editquality-reverted' for release 'main' .
15:53 ladsgroup@cumin1001: dbctl commit (dc=all): 'db1166 (re)pooling @ 25%: Maint Done', diff saved to https://phabricator.wikimedia.org/P34907 and previous config saved to /var/cache/conftool/dbconfig/20220926-155312-ladsgroup.json
15:52 elukey@deploy1002: helmfile [ml-staging-codfw] Ran 'sync' command on namespace 'revscoring-editquality-damaging' for release 'main' .
15:51 elukey@deploy1002: helmfile [ml-staging-codfw] Ran 'sync' command on namespace 'revscoring-editquality-goodfaith' for release 'main' .
15:47 elukey@deploy1002: helmfile [ml-staging-codfw] Ran 'sync' command on namespace 'revscoring-articlequality' for release 'main' .
15:43 volans@cumin2002: START - Cookbook sre.hosts.provision for host db2183.mgmt.codfw.wmnet with reboot policy FORCED
15:40 ladsgroup@deploy1002: Synchronized portals: Migrate wikiversity.org to the modern portals (duration: 03m 36s)
15:38 ladsgroup@cumin1001: dbctl commit (dc=all): 'db1166 (re)pooling @ 10%: Maint Done', diff saved to https://phabricator.wikimedia.org/P34906 and previous config saved to /var/cache/conftool/dbconfig/20220926-153807-ladsgroup.json
15:37 ladsgroup@deploy1002: Synchronized portals/wikipedia.org/assets: Migrate wikiversity.org to the modern portals (duration: 03m 49s)
14:49 ladsgroup@cumin1001: END (PASS) - Cookbook sre.hosts.downtime (exit_code=0) for 1 day, 0:00:00 on db2102.codfw.wmnet with reason: Maintenance
14:48 ladsgroup@cumin1001: START - Cookbook sre.hosts.downtime for 1 day, 0:00:00 on db2102.codfw.wmnet with reason: Maintenance
13:59 aqu@deploy1002: Finished deploy [airflow-dags/analytics_test@a69b031]: Make Airflow jobs use Spark 3 on anlytics_test [airflow-dags@a69b031] (duration: 00m 09s)
13:59 aqu@deploy1002: Started deploy [airflow-dags/analytics_test@a69b031]: Make Airflow jobs use Spark 3 on anlytics_test [airflow-dags@a69b031]
13:56 moritzm: installing mako security updates
13:47 aqu@deploy1002: Finished deploy [airflow-dags/analytics@a69b031]: Make Airflow jobs use Spark 3 on anlytics [airflow-dags@a69b031] (duration: 00m 10s)
13:46 aqu@deploy1002: Started deploy [airflow-dags/analytics@a69b031]: Make Airflow jobs use Spark 3 on anlytics [airflow-dags@a69b031]
13:45 Lucas_WMDE: UTC afternoon backport+config window done
13:41 lucaswerkmeister-wmde@deploy1002: Synchronized php-1.40.0-wmf.2/extensions/WikimediaIncubator/extension.json: Backport: Set default sortkey for prefixed pages (T315551) (2/2) (duration: 03m 39s)
12:45 ladsgroup@deploy1002: ladsgroup and ladsgroup: Backport for Bump portals to HEAD (T273179) synced to the testservers: mwdebug2001.codfw.wmnet, mwdebug1002.eqiad.wmnet, mwdebug1001.eqiad.wmnet, mwdebug2002.codfw.wmnet
07:26 oblivian@deploy1002: oblivian and oblivian: Backport for Move 100% of cookie-accepting clients to php 7.4 (T271736) synced to the testservers: mwdebug1002.eqiad.wmnet, mwdebug2002.codfw.wmnet, mwdebug1001.eqiad.wmnet, mwdebug2001.codfw.wmnet
06:36 elukey: clean up my old home dir on matomo1002, ran `apt-get clean` + some other clean up steps on matomo1002 to free space on the root partition
17:29 andrew@cumin1001: END (PASS) - Cookbook sre.hosts.reimage (exit_code=0) for host cloudvirt1053.eqiad.wmnet with OS bullseye
17:08 andrew@cumin1001: END (PASS) - Cookbook sre.hosts.downtime (exit_code=0) for 2:00:00 on cloudvirt1053.eqiad.wmnet with reason: host reimage
17:05 andrew@cumin1001: START - Cookbook sre.hosts.downtime for 2:00:00 on cloudvirt1053.eqiad.wmnet with reason: host reimage
16:51 andrew@cumin1001: START - Cookbook sre.hosts.reimage for host cloudvirt1053.eqiad.wmnet with OS bullseye
16:49 andrew@cumin1001: END (PASS) - Cookbook sre.hosts.reimage (exit_code=0) for host cloudvirt1052.eqiad.wmnet with OS bullseye
16:23 andrew@cumin1001: END (PASS) - Cookbook sre.hosts.downtime (exit_code=0) for 2:00:00 on cloudvirt1052.eqiad.wmnet with reason: host reimage
16:20 andrew@cumin1001: START - Cookbook sre.hosts.downtime for 2:00:00 on cloudvirt1052.eqiad.wmnet with reason: host reimage
16:06 andrew@cumin1001: START - Cookbook sre.hosts.reimage for host cloudvirt1052.eqiad.wmnet with OS bullseye
15:59 andrew@cumin1001: END (PASS) - Cookbook sre.hosts.reimage (exit_code=0) for host cloudvirt1052.eqiad.wmnet with OS bullseye
15:31 andrew@cumin1001: END (PASS) - Cookbook sre.hosts.downtime (exit_code=0) for 2:00:00 on cloudvirt1052.eqiad.wmnet with reason: host reimage
15:26 andrew@cumin1001: START - Cookbook sre.hosts.downtime for 2:00:00 on cloudvirt1052.eqiad.wmnet with reason: host reimage
15:26 taavi@deploy1002: Finished deploy [horizon/deploy@9d02cd6]: wmf-proxy-dashboard now uses the dynamicproxy api to fetch zone data (duration: 02m 44s)
15:23 taavi@deploy1002: Started deploy [horizon/deploy@9d02cd6]: wmf-proxy-dashboard now uses the dynamicproxy api to fetch zone data
15:22 taavi@deploy1002: Finished deploy [horizon/deploy@9d02cd6] (dev): wmf-proxy-dashboard now uses the dynamicproxy api to fetch zone data (duration: 01m 11s)
15:20 taavi@deploy1002: Started deploy [horizon/deploy@9d02cd6] (dev): wmf-proxy-dashboard now uses the dynamicproxy api to fetch zone data
15:15 taavi@deploy1002: Finished deploy [horizon/deploy@9d02cd6] (dev): wmf-proxy-dashboard now uses the dynamicproxy api to fetch zone data (duration: 01m 10s)
15:14 taavi@deploy1002: Started deploy [horizon/deploy@9d02cd6] (dev): wmf-proxy-dashboard now uses the dynamicproxy api to fetch zone data
15:13 andrew@cumin1001: START - Cookbook sre.hosts.reimage for host cloudvirt1052.eqiad.wmnet with OS bullseye
13:23 taavi@deploy1002: Started deploy [horizon/deploy@9d02cd6] (dev): wmf-proxy-dashboard improved error handling
09:26 jynus: stopping db1117:s3 for maintenance T315713
08:51 Emperor: rebalance ms-eqiad swift rings T294550
07:36 marostegui@cumin1001: END (PASS) - Cookbook sre.hosts.downtime (exit_code=0) for 4:00:00 on db[2134,2160].codfw.wmnet,db[1117,1159].eqiad.wmnet with reason: Grants fixing
07:36 marostegui@cumin1001: START - Cookbook sre.hosts.downtime for 4:00:00 on db[2134,2160].codfw.wmnet,db[1117,1159].eqiad.wmnet with reason: Grants fixing
06:09 marostegui@cumin1001: END (PASS) - Cookbook sre.hosts.downtime (exit_code=0) for 4 days, 0:00:00 on db1189.eqiad.wmnet with reason: on site maintenance
06:09 marostegui@cumin1001: START - Cookbook sre.hosts.downtime for 4 days, 0:00:00 on db1189.eqiad.wmnet with reason: on site maintenance
20:19 brennen@deploy1002: brennen and tpt: Backport for Drops JS-side creation of "Source" link (T318266) synced to the testservers: mwdebug2002.codfw.wmnet, mwdebug1002.eqiad.wmnet, mwdebug1001.eqiad.wmnet, mwdebug2001.codfw.wmnet
20:21 samtar@deploy1002: samtar and ebernhardson: Backport for cirrus: Limit shard count to 1 in deployment-prep (T316711) synced to the testservers: mwdebug1002.eqiad.wmnet, mwdebug2001.codfw.wmnet, mwdebug2002.codfw.wmnet, mwdebug1001.eqiad.wmnet
20:04 samtar@deploy1002: samtar and zabe: Backport for Remove deployment-db08 (T318126) synced to the testservers: mwdebug1002.eqiad.wmnet, mwdebug2001.codfw.wmnet, mwdebug2002.codfw.wmnet, mwdebug1001.eqiad.wmnet
18:38 nokafor@deploy1002: Started deploy [analytics/refinery@91d0cf8]: Regular analytics weekly train [analytics/refinery@91d0cf8]
14:56 Emperor: set thanos ring replicas to 3.75 T311690
14:50 lucaswerkmeister-wmde@deploy1002: Synchronized wmf-config/db-labs.php: Config: Pool deployment-db09, depool deployment-db08 (T318126) (Beta-only, exchange one replica for another) [*actually* sync it this time since I forgot to git rebase before the last sync đ¤Ś] (duration: 03m 41s)
20:05 cjming@deploy1002: cjming and jdlrobson: Backport for Enable Nearby everywhere (T246493) synced to the testservers: mwdebug2002.codfw.wmnet, mwdebug2001.codfw.wmnet, mwdebug1001.eqiad.wmnet, mwdebug1002.eqiad.wmnet
20:06 cjming@deploy1002: cjming and arlolra: Backport for Disable wgParserEnableLegacyMediaDOM on cswiki (T314318) synced to the testservers: mwdebug1001.eqiad.wmnet, mwdebug2002.codfw.wmnet, mwdebug2001.codfw.wmnet, mwdebug1002.eqiad.wmnet
12:17 Emperor: set thanos ring replicas to 3.80 T311690
10:39 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db2105 (T314041)', diff saved to https://phabricator.wikimedia.org/P34879 and previous config saved to /var/cache/conftool/dbconfig/20220917-103903-ladsgroup.json
10:23 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db2105', diff saved to https://phabricator.wikimedia.org/P34878 and previous config saved to /var/cache/conftool/dbconfig/20220917-102356-ladsgroup.json
10:08 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db2105', diff saved to https://phabricator.wikimedia.org/P34877 and previous config saved to /var/cache/conftool/dbconfig/20220917-100850-ladsgroup.json
09:53 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db2105 (T314041)', diff saved to https://phabricator.wikimedia.org/P34876 and previous config saved to /var/cache/conftool/dbconfig/20220917-095344-ladsgroup.json
09:48 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db1127 (T314041)', diff saved to https://phabricator.wikimedia.org/P34875 and previous config saved to /var/cache/conftool/dbconfig/20220917-094856-ladsgroup.json
09:33 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db1127', diff saved to https://phabricator.wikimedia.org/P34874 and previous config saved to /var/cache/conftool/dbconfig/20220917-093349-ladsgroup.json
09:18 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db1127', diff saved to https://phabricator.wikimedia.org/P34873 and previous config saved to /var/cache/conftool/dbconfig/20220917-091843-ladsgroup.json
09:03 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db1127 (T314041)', diff saved to https://phabricator.wikimedia.org/P34872 and previous config saved to /var/cache/conftool/dbconfig/20220917-090336-ladsgroup.json
07:48 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db2129 (T314041)', diff saved to https://phabricator.wikimedia.org/P34871 and previous config saved to /var/cache/conftool/dbconfig/20220917-074806-ladsgroup.json
07:33 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db2129', diff saved to https://phabricator.wikimedia.org/P34870 and previous config saved to /var/cache/conftool/dbconfig/20220917-073300-ladsgroup.json
07:17 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db2129', diff saved to https://phabricator.wikimedia.org/P34869 and previous config saved to /var/cache/conftool/dbconfig/20220917-071753-ladsgroup.json
07:02 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db2129 (T314041)', diff saved to https://phabricator.wikimedia.org/P34868 and previous config saved to /var/cache/conftool/dbconfig/20220917-070247-ladsgroup.json
05:17 ladsgroup@cumin1001: dbctl commit (dc=all): 'Depooling db2105 (T314041)', diff saved to https://phabricator.wikimedia.org/P34867 and previous config saved to /var/cache/conftool/dbconfig/20220917-051719-ladsgroup.json
05:17 ladsgroup@cumin1001: END (PASS) - Cookbook sre.hosts.downtime (exit_code=0) for 1 day, 0:00:00 on db2105.codfw.wmnet with reason: Maintenance
05:17 ladsgroup@cumin1001: START - Cookbook sre.hosts.downtime for 1 day, 0:00:00 on db2105.codfw.wmnet with reason: Maintenance
05:15 ladsgroup@cumin1001: dbctl commit (dc=all): 'Depooling db2129 (T314041)', diff saved to https://phabricator.wikimedia.org/P34866 and previous config saved to /var/cache/conftool/dbconfig/20220917-051527-ladsgroup.json
05:15 ladsgroup@cumin1001: END (PASS) - Cookbook sre.hosts.downtime (exit_code=0) for 1 day, 0:00:00 on db2129.codfw.wmnet with reason: Maintenance
05:15 ladsgroup@cumin1001: START - Cookbook sre.hosts.downtime for 1 day, 0:00:00 on db2129.codfw.wmnet with reason: Maintenance
05:12 ladsgroup@cumin1001: dbctl commit (dc=all): 'Depooling db1127 (T314041)', diff saved to https://phabricator.wikimedia.org/P34865 and previous config saved to /var/cache/conftool/dbconfig/20220917-051203-ladsgroup.json
05:11 ladsgroup@cumin1001: END (PASS) - Cookbook sre.hosts.downtime (exit_code=0) for 1 day, 0:00:00 on db1127.eqiad.wmnet with reason: Maintenance
05:11 ladsgroup@cumin1001: START - Cookbook sre.hosts.downtime for 1 day, 0:00:00 on db1127.eqiad.wmnet with reason: Maintenance
2022-09-16
21:29 ladsgroup@cumin1001: END (PASS) - Cookbook sre.hosts.downtime (exit_code=0) for 1 day, 0:00:00 on dbstore1007.eqiad.wmnet with reason: Maintenance
21:29 ladsgroup@cumin1001: START - Cookbook sre.hosts.downtime for 1 day, 0:00:00 on dbstore1007.eqiad.wmnet with reason: Maintenance
21:29 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db1198 (T314041)', diff saved to https://phabricator.wikimedia.org/P34864 and previous config saved to /var/cache/conftool/dbconfig/20220916-212905-ladsgroup.json
21:13 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db1198', diff saved to https://phabricator.wikimedia.org/P34863 and previous config saved to /var/cache/conftool/dbconfig/20220916-211358-ladsgroup.json
20:58 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db1198', diff saved to https://phabricator.wikimedia.org/P34862 and previous config saved to /var/cache/conftool/dbconfig/20220916-205852-ladsgroup.json
20:43 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db1198 (T314041)', diff saved to https://phabricator.wikimedia.org/P34861 and previous config saved to /var/cache/conftool/dbconfig/20220916-204345-ladsgroup.json
16:42 pt1979@cumin2002: END (PASS) - Cookbook sre.network.configure-switch-interfaces (exit_code=0) for host db2184
16:42 pt1979@cumin2002: START - Cookbook sre.network.configure-switch-interfaces for host db2184
16:42 pt1979@cumin2002: END (PASS) - Cookbook sre.network.configure-switch-interfaces (exit_code=0) for host db2183
16:41 pt1979@cumin2002: START - Cookbook sre.network.configure-switch-interfaces for host db2183
16:14 ladsgroup@cumin1001: dbctl commit (dc=all): 'Depooling db1198 (T314041)', diff saved to https://phabricator.wikimedia.org/P34860 and previous config saved to /var/cache/conftool/dbconfig/20220916-161409-ladsgroup.json
16:14 ladsgroup@cumin1001: END (PASS) - Cookbook sre.hosts.downtime (exit_code=0) for 1 day, 0:00:00 on db1198.eqiad.wmnet with reason: Maintenance
16:13 ladsgroup@cumin1001: START - Cookbook sre.hosts.downtime for 1 day, 0:00:00 on db1198.eqiad.wmnet with reason: Maintenance
16:13 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db1189 (T314041)', diff saved to https://phabricator.wikimedia.org/P34859 and previous config saved to /var/cache/conftool/dbconfig/20220916-161346-ladsgroup.json
15:58 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db1189', diff saved to https://phabricator.wikimedia.org/P34858 and previous config saved to /var/cache/conftool/dbconfig/20220916-155840-ladsgroup.json
15:52 elukey@deploy1002: helmfile [ml-serve-eqiad] Ran 'sync' command on namespace 'revscoring-editquality-damaging' for release 'main' .
15:52 dancy@deploy1002: Installation of scap version "4.20.0" completed for 561 hosts
15:51 dancy@deploy1002: Installing scap version "4.20.0" for 561 hosts
15:51 elukey@deploy1002: helmfile [ml-serve-eqiad] Ran 'sync' command on namespace 'revscoring-editquality-goodfaith' for release 'main' .
15:43 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db1189', diff saved to https://phabricator.wikimedia.org/P34857 and previous config saved to /var/cache/conftool/dbconfig/20220916-154333-ladsgroup.json
15:39 dancy@deploy1002: Started scap: testing
15:28 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db1189 (T314041)', diff saved to https://phabricator.wikimedia.org/P34856 and previous config saved to /var/cache/conftool/dbconfig/20220916-152827-ladsgroup.json
15:06 elukey@deploy1002: helmfile [ml-serve-eqiad] Ran 'sync' command on namespace 'revscoring-editquality-reverted' for release 'main' .
15:05 elukey@deploy1002: helmfile [ml-serve-eqiad] Ran 'sync' command on namespace 'revscoring-drafttopic' for release 'main' .
15:05 elukey@deploy1002: helmfile [ml-serve-eqiad] Ran 'sync' command on namespace 'revscoring-draftquality' for release 'main' .
15:04 elukey@deploy1002: helmfile [ml-serve-eqiad] Ran 'sync' command on namespace 'revscoring-articletopic' for release 'main' .
15:03 elukey@deploy1002: helmfile [ml-serve-eqiad] Ran 'sync' command on namespace 'revscoring-articlequality' for release 'main' .
12:33 marostegui@cumin1001: dbctl commit (dc=all): 'db1114 (re)pooling @ 25%: After upgrade', diff saved to https://phabricator.wikimedia.org/P34850 and previous config saved to /var/cache/conftool/dbconfig/20220916-123346-root.json
12:28 marostegui@cumin1001: dbctl commit (dc=all): 'db1134 (re)pooling @ 50%: Repooling after upgrade', diff saved to https://phabricator.wikimedia.org/P34849 and previous config saved to /var/cache/conftool/dbconfig/20220916-122831-root.json
12:18 marostegui@cumin1001: dbctl commit (dc=all): 'db1114 (re)pooling @ 10%: After upgrade', diff saved to https://phabricator.wikimedia.org/P34848 and previous config saved to /var/cache/conftool/dbconfig/20220916-121841-root.json
12:13 marostegui@cumin1001: dbctl commit (dc=all): 'db1134 (re)pooling @ 25%: Repooling after upgrade', diff saved to https://phabricator.wikimedia.org/P34847 and previous config saved to /var/cache/conftool/dbconfig/20220916-121326-root.json
12:03 marostegui@cumin1001: dbctl commit (dc=all): 'db1114 (re)pooling @ 5%: After upgrade', diff saved to https://phabricator.wikimedia.org/P34846 and previous config saved to /var/cache/conftool/dbconfig/20220916-120336-root.json
11:58 marostegui@cumin1001: dbctl commit (dc=all): 'db1134 (re)pooling @ 10%: Repooling after upgrade', diff saved to https://phabricator.wikimedia.org/P34845 and previous config saved to /var/cache/conftool/dbconfig/20220916-115821-root.json
11:49 marostegui@cumin1001: dbctl commit (dc=all): 'db2180 (re)pooling @ 100%: After upgrade', diff saved to https://phabricator.wikimedia.org/P34844 and previous config saved to /var/cache/conftool/dbconfig/20220916-114935-root.json
11:48 marostegui@cumin1001: dbctl commit (dc=all): 'db1114 (re)pooling @ 3%: After upgrade', diff saved to https://phabricator.wikimedia.org/P34843 and previous config saved to /var/cache/conftool/dbconfig/20220916-114831-root.json
11:43 marostegui@cumin1001: dbctl commit (dc=all): 'db1134 (re)pooling @ 5%: Repooling after upgrade', diff saved to https://phabricator.wikimedia.org/P34842 and previous config saved to /var/cache/conftool/dbconfig/20220916-114316-root.json
11:35 marostegui@cumin1001: dbctl commit (dc=all): 'Depool db1134', diff saved to https://phabricator.wikimedia.org/P34841 and previous config saved to /var/cache/conftool/dbconfig/20220916-113543-root.json
11:34 marostegui@cumin1001: dbctl commit (dc=all): 'db2180 (re)pooling @ 75%: After upgrade', diff saved to https://phabricator.wikimedia.org/P34840 and previous config saved to /var/cache/conftool/dbconfig/20220916-113431-root.json
11:33 marostegui@cumin1001: dbctl commit (dc=all): 'db1114 (re)pooling @ 1%: After upgrade', diff saved to https://phabricator.wikimedia.org/P34839 and previous config saved to /var/cache/conftool/dbconfig/20220916-113325-root.json
11:27 marostegui@cumin1001: dbctl commit (dc=all): 'Depool db1114', diff saved to https://phabricator.wikimedia.org/P34838 and previous config saved to /var/cache/conftool/dbconfig/20220916-112750-root.json
11:19 marostegui@cumin1001: dbctl commit (dc=all): 'db2180 (re)pooling @ 50%: After upgrade', diff saved to https://phabricator.wikimedia.org/P34837 and previous config saved to /var/cache/conftool/dbconfig/20220916-111925-root.json
11:04 marostegui@cumin1001: dbctl commit (dc=all): 'db2180 (re)pooling @ 25%: After upgrade', diff saved to https://phabricator.wikimedia.org/P34836 and previous config saved to /var/cache/conftool/dbconfig/20220916-110420-root.json
10:58 ladsgroup@cumin1001: dbctl commit (dc=all): 'Depooling db1189 (T314041)', diff saved to https://phabricator.wikimedia.org/P34835 and previous config saved to /var/cache/conftool/dbconfig/20220916-105819-ladsgroup.json
10:58 ladsgroup@cumin1001: END (PASS) - Cookbook sre.hosts.downtime (exit_code=0) for 1 day, 0:00:00 on db1189.eqiad.wmnet with reason: Maintenance
10:58 ladsgroup@cumin1001: START - Cookbook sre.hosts.downtime for 1 day, 0:00:00 on db1189.eqiad.wmnet with reason: Maintenance
10:58 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db1166 (T314041)', diff saved to https://phabricator.wikimedia.org/P34834 and previous config saved to /var/cache/conftool/dbconfig/20220916-105809-ladsgroup.json
10:49 marostegui@cumin1001: dbctl commit (dc=all): 'db2180 (re)pooling @ 10%: After upgrade', diff saved to https://phabricator.wikimedia.org/P34832 and previous config saved to /var/cache/conftool/dbconfig/20220916-104916-root.json
10:43 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db1166', diff saved to https://phabricator.wikimedia.org/P34831 and previous config saved to /var/cache/conftool/dbconfig/20220916-104303-ladsgroup.json
10:34 marostegui@cumin1001: dbctl commit (dc=all): 'db2180 (re)pooling @ 5%: After upgrade', diff saved to https://phabricator.wikimedia.org/P34830 and previous config saved to /var/cache/conftool/dbconfig/20220916-103411-root.json
10:27 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db1166', diff saved to https://phabricator.wikimedia.org/P34829 and previous config saved to /var/cache/conftool/dbconfig/20220916-102756-ladsgroup.json
10:19 marostegui@cumin1001: dbctl commit (dc=all): 'db2180 (re)pooling @ 3%: After upgrade', diff saved to https://phabricator.wikimedia.org/P34828 and previous config saved to /var/cache/conftool/dbconfig/20220916-101905-root.json
10:12 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db1166 (T314041)', diff saved to https://phabricator.wikimedia.org/P34827 and previous config saved to /var/cache/conftool/dbconfig/20220916-101250-ladsgroup.json
10:04 marostegui@cumin1001: dbctl commit (dc=all): 'db2180 (re)pooling @ 1%: After upgrade', diff saved to https://phabricator.wikimedia.org/P34826 and previous config saved to /var/cache/conftool/dbconfig/20220916-100400-root.json
09:36 marostegui@cumin1001: dbctl commit (dc=all): 'db1189 (re)pooling @ 100%: After being recloned', diff saved to https://phabricator.wikimedia.org/P34825 and previous config saved to /var/cache/conftool/dbconfig/20220916-093635-root.json
09:31 marostegui@cumin1001: dbctl commit (dc=all): 'db1198 (re)pooling @ 100%: Repooling after cloning db1189', diff saved to https://phabricator.wikimedia.org/P34824 and previous config saved to /var/cache/conftool/dbconfig/20220916-093121-root.json
09:21 marostegui@cumin1001: dbctl commit (dc=all): 'db1189 (re)pooling @ 75%: After being recloned', diff saved to https://phabricator.wikimedia.org/P34823 and previous config saved to /var/cache/conftool/dbconfig/20220916-092130-root.json
09:16 marostegui@cumin1001: dbctl commit (dc=all): 'db1198 (re)pooling @ 75%: Repooling after cloning db1189', diff saved to https://phabricator.wikimedia.org/P34822 and previous config saved to /var/cache/conftool/dbconfig/20220916-091616-root.json
09:12 ladsgroup@cumin1001: dbctl commit (dc=all): 'Depooling db1166 (T314041)', diff saved to https://phabricator.wikimedia.org/P34821 and previous config saved to /var/cache/conftool/dbconfig/20220916-091234-ladsgroup.json
09:12 ladsgroup@cumin1001: END (PASS) - Cookbook sre.hosts.downtime (exit_code=0) for 1 day, 0:00:00 on db1166.eqiad.wmnet with reason: Maintenance
09:12 ladsgroup@cumin1001: START - Cookbook sre.hosts.downtime for 1 day, 0:00:00 on db1166.eqiad.wmnet with reason: Maintenance
09:06 marostegui@cumin1001: dbctl commit (dc=all): 'db1189 (re)pooling @ 50%: After being recloned', diff saved to https://phabricator.wikimedia.org/P34820 and previous config saved to /var/cache/conftool/dbconfig/20220916-090625-root.json
09:01 marostegui@cumin1001: dbctl commit (dc=all): 'db1198 (re)pooling @ 50%: Repooling after cloning db1189', diff saved to https://phabricator.wikimedia.org/P34819 and previous config saved to /var/cache/conftool/dbconfig/20220916-090111-root.json
08:51 marostegui@cumin1001: dbctl commit (dc=all): 'db1189 (re)pooling @ 25%: After being recloned', diff saved to https://phabricator.wikimedia.org/P34818 and previous config saved to /var/cache/conftool/dbconfig/20220916-085120-root.json
08:46 marostegui@cumin1001: dbctl commit (dc=all): 'db1198 (re)pooling @ 25%: Repooling after cloning db1189', diff saved to https://phabricator.wikimedia.org/P34817 and previous config saved to /var/cache/conftool/dbconfig/20220916-084607-root.json
08:36 marostegui@cumin1001: dbctl commit (dc=all): 'db1189 (re)pooling @ 10%: After being recloned', diff saved to https://phabricator.wikimedia.org/P34816 and previous config saved to /var/cache/conftool/dbconfig/20220916-083615-root.json
08:31 marostegui@cumin1001: dbctl commit (dc=all): 'db1198 (re)pooling @ 10%: Repooling after cloning db1189', diff saved to https://phabricator.wikimedia.org/P34815 and previous config saved to /var/cache/conftool/dbconfig/20220916-083102-root.json
08:21 marostegui@cumin1001: dbctl commit (dc=all): 'db1189 (re)pooling @ 5%: After being recloned', diff saved to https://phabricator.wikimedia.org/P34814 and previous config saved to /var/cache/conftool/dbconfig/20220916-082110-root.json
08:15 marostegui@cumin1001: dbctl commit (dc=all): 'db1198 (re)pooling @ 5%: Repooling after cloning db1189', diff saved to https://phabricator.wikimedia.org/P34813 and previous config saved to /var/cache/conftool/dbconfig/20220916-081557-root.json
08:06 marostegui@cumin1001: dbctl commit (dc=all): 'db1189 (re)pooling @ 3%: After being recloned', diff saved to https://phabricator.wikimedia.org/P34812 and previous config saved to /var/cache/conftool/dbconfig/20220916-080605-root.json
08:00 marostegui@cumin1001: dbctl commit (dc=all): 'db1198 (re)pooling @ 3%: Repooling after cloning db1189', diff saved to https://phabricator.wikimedia.org/P34811 and previous config saved to /var/cache/conftool/dbconfig/20220916-080052-root.json
07:51 marostegui@cumin1001: dbctl commit (dc=all): 'db1189 (re)pooling @ 1%: After being recloned', diff saved to https://phabricator.wikimedia.org/P34810 and previous config saved to /var/cache/conftool/dbconfig/20220916-075100-root.json
07:45 marostegui@cumin1001: dbctl commit (dc=all): 'db1198 (re)pooling @ 1%: Repooling after cloning db1189', diff saved to https://phabricator.wikimedia.org/P34809 and previous config saved to /var/cache/conftool/dbconfig/20220916-074548-root.json
07:42 marostegui@cumin1001: dbctl commit (dc=all): 'db1168 (re)pooling @ 100%: After upgrade', diff saved to https://phabricator.wikimedia.org/P34808 and previous config saved to /var/cache/conftool/dbconfig/20220916-074251-root.json
07:29 marostegui@cumin1001: dbctl commit (dc=all): 'Depool db2180', diff saved to https://phabricator.wikimedia.org/P34807 and previous config saved to /var/cache/conftool/dbconfig/20220916-072958-root.json
07:27 marostegui@cumin1001: dbctl commit (dc=all): 'db1168 (re)pooling @ 75%: After upgrade', diff saved to https://phabricator.wikimedia.org/P34806 and previous config saved to /var/cache/conftool/dbconfig/20220916-072746-root.json
15:11 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db1190 (T314041)', diff saved to https://phabricator.wikimedia.org/P34792 and previous config saved to /var/cache/conftool/dbconfig/20220915-151131-ladsgroup.json
14:56 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db1190', diff saved to https://phabricator.wikimedia.org/P34791 and previous config saved to /var/cache/conftool/dbconfig/20220915-145625-ladsgroup.json
14:41 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db1190', diff saved to https://phabricator.wikimedia.org/P34790 and previous config saved to /var/cache/conftool/dbconfig/20220915-144118-ladsgroup.json
14:26 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db1190 (T314041)', diff saved to https://phabricator.wikimedia.org/P34789 and previous config saved to /var/cache/conftool/dbconfig/20220915-142612-ladsgroup.json
14:01 sukhe: retarting bird.service on A:dns-auth for zlib update
14:00 urbanecm@deploy1002: Synchronized wmf-config/InitialiseSettings.php: 6b9784a: Enable the Vue version of the mentee overview in pilot wikis (T300532) (duration: 03m 45s)
13:47 aqu@deploy1002: Finished deploy [analytics/refinery@278c383] (hadoop-test): Regular analytics weekly train TEST (second try after freeing up some disk space) [analytics/refinery@278c383] (duration: 06m 01s)
13:41 aqu@deploy1002: Started deploy [analytics/refinery@278c383] (hadoop-test): Regular analytics weekly train TEST (second try after freeing up some disk space) [analytics/refinery@278c383]
13:38 sukhe: restarting bird.service on A:dns-rec for zlib update
12:46 hnowlan@cumin1001: END (PASS) - Cookbook sre.hosts.downtime (exit_code=0) for 1:00:00 on sessionstore1001.eqiad.wmnet with reason: temporarily disabled due to sessionstore issues
12:46 hnowlan@cumin1001: START - Cookbook sre.hosts.downtime for 1:00:00 on sessionstore1001.eqiad.wmnet with reason: temporarily disabled due to sessionstore issues
12:25 hnowlan@cumin1001: END (PASS) - Cookbook sre.hosts.reimage (exit_code=0) for host sessionstore1001.eqiad.wmnet with OS buster
12:17 jayme: fleet wide update of prometheus-rsyslog-exporter to 0.0.0+git20201008-4 - T289766
12:10 hnowlan@cumin1001: END (PASS) - Cookbook sre.hosts.downtime (exit_code=0) for 2:00:00 on sessionstore1001.eqiad.wmnet with reason: host reimage
12:06 hnowlan@cumin1001: START - Cookbook sre.hosts.downtime for 2:00:00 on sessionstore1001.eqiad.wmnet with reason: host reimage
12:00 marostegui@cumin1001: dbctl commit (dc=all): 'db2131 (re)pooling @ 100%: Repooling for warm up after upgrade', diff saved to https://phabricator.wikimedia.org/P34787 and previous config saved to /var/cache/conftool/dbconfig/20220915-120013-root.json
11:51 hnowlan@cumin1001: START - Cookbook sre.hosts.reimage for host sessionstore1001.eqiad.wmnet with OS buster
11:50 hnowlan@cumin1001: END (ERROR) - Cookbook sre.hosts.reimage (exit_code=97) for host sessionstore1001.eqiad.wmnet with OS buster
11:45 hnowlan@cumin1001: START - Cookbook sre.hosts.reimage for host sessionstore1001.eqiad.wmnet with OS buster
11:45 marostegui@cumin1001: dbctl commit (dc=all): 'db2131 (re)pooling @ 75%: Repooling for warm up after upgrade', diff saved to https://phabricator.wikimedia.org/P34786 and previous config saved to /var/cache/conftool/dbconfig/20220915-114508-root.json
11:44 hnowlan@cumin1001: END (ERROR) - Cookbook sre.hosts.reimage (exit_code=97) for host sessionstore1001.eqiad.wmnet with OS buster
11:43 moritzm: restart exim on lists1001 to pick up zlib security updates
11:30 marostegui@cumin1001: dbctl commit (dc=all): 'db2131 (re)pooling @ 50%: Repooling for warm up after upgrade', diff saved to https://phabricator.wikimedia.org/P34785 and previous config saved to /var/cache/conftool/dbconfig/20220915-113003-root.json
11:22 hnowlan@cumin1001: START - Cookbook sre.hosts.reimage for host sessionstore1001.eqiad.wmnet with OS buster
11:17 jmm@cumin2002: END (PASS) - Cookbook sre.wdqs.restart-nginx (exit_code=0) rolling restart_daemons on A:wcqs-public
11:15 jmm@cumin2002: START - Cookbook sre.wdqs.restart-nginx rolling restart_daemons on A:wcqs-public
11:14 marostegui@cumin1001: dbctl commit (dc=all): 'db2131 (re)pooling @ 25%: Repooling for warm up after upgrade', diff saved to https://phabricator.wikimedia.org/P34784 and previous config saved to /var/cache/conftool/dbconfig/20220915-111458-root.json
11:10 hnowlan@cumin1001: END (PASS) - Cookbook sre.hosts.downtime (exit_code=0) for 1:00:00 on sessionstore1001.eqiad.wmnet with reason: Testing reimage
11:10 hnowlan@cumin1001: START - Cookbook sre.hosts.downtime for 1:00:00 on sessionstore1001.eqiad.wmnet with reason: Testing reimage
11:04 marostegui@cumin1001: dbctl commit (dc=all): 'pool db2129 into s6 API', diff saved to https://phabricator.wikimedia.org/P34783 and previous config saved to /var/cache/conftool/dbconfig/20220915-110453-root.json
10:59 marostegui@cumin1001: dbctl commit (dc=all): 'db2131 (re)pooling @ 10%: Repooling for warm up after upgrade', diff saved to https://phabricator.wikimedia.org/P34782 and previous config saved to /var/cache/conftool/dbconfig/20220915-105953-root.json
10:44 marostegui@cumin1001: dbctl commit (dc=all): 'db2131 (re)pooling @ 5%: Repooling for warm up after upgrade', diff saved to https://phabricator.wikimedia.org/P34781 and previous config saved to /var/cache/conftool/dbconfig/20220915-104448-root.json
10:36 elukey@deploy1002: helmfile [ml-serve-eqiad] Ran 'sync' command on namespace 'revscoring-editquality-damaging' for release 'main' .
10:29 marostegui@cumin1001: dbctl commit (dc=all): 'db2131 (re)pooling @ 3%: Repooling for warm up after upgrade', diff saved to https://phabricator.wikimedia.org/P34780 and previous config saved to /var/cache/conftool/dbconfig/20220915-102943-root.json
10:14 marostegui@cumin1001: dbctl commit (dc=all): 'db2131 (re)pooling @ 1%: Repooling for warm up after upgrade', diff saved to https://phabricator.wikimedia.org/P34779 and previous config saved to /var/cache/conftool/dbconfig/20220915-101438-root.json
10:14 marostegui@cumin1001: dbctl commit (dc=all): 'db2129 (re)pooling @ 100%: Repooling for warm up after upgrade', diff saved to https://phabricator.wikimedia.org/P34778 and previous config saved to /var/cache/conftool/dbconfig/20220915-101425-root.json
10:04 marostegui@cumin1001: END (PASS) - Cookbook sre.hosts.downtime (exit_code=0) for 7:00:00 on db2131.codfw.wmnet with reason: reboot
10:03 marostegui@cumin1001: START - Cookbook sre.hosts.downtime for 7:00:00 on db2131.codfw.wmnet with reason: reboot
10:02 marostegui@cumin1001: dbctl commit (dc=all): 'Depool db2131', diff saved to https://phabricator.wikimedia.org/P34777 and previous config saved to /var/cache/conftool/dbconfig/20220915-100212-root.json
09:59 marostegui@cumin1001: dbctl commit (dc=all): 'db2129 (re)pooling @ 75%: Repooling for warm up after upgrade', diff saved to https://phabricator.wikimedia.org/P34775 and previous config saved to /var/cache/conftool/dbconfig/20220915-095920-root.json
09:58 elukey@deploy1002: helmfile [ml-serve-eqiad] Ran 'sync' command on namespace 'revscoring-editquality-goodfaith' for release 'main' .
09:58 elukey@deploy1002: helmfile [ml-serve-eqiad] Ran 'sync' command on namespace 'revscoring-editquality-reverted' for release 'main' .
09:57 elukey@deploy1002: helmfile [ml-serve-eqiad] Ran 'sync' command on namespace 'revscoring-drafttopic' for release 'main' .
09:57 elukey@deploy1002: helmfile [ml-serve-eqiad] Ran 'sync' command on namespace 'revscoring-draftquality' for release 'main' .
09:56 elukey@deploy1002: helmfile [ml-serve-eqiad] Ran 'sync' command on namespace 'revscoring-articletopic' for release 'main' .
09:44 marostegui@cumin1001: dbctl commit (dc=all): 'db2129 (re)pooling @ 50%: Repooling for warm up after upgrade', diff saved to https://phabricator.wikimedia.org/P34774 and previous config saved to /var/cache/conftool/dbconfig/20220915-094415-root.json
09:29 marostegui@cumin1001: dbctl commit (dc=all): 'db2129 (re)pooling @ 25%: Repooling for warm up after upgrade', diff saved to https://phabricator.wikimedia.org/P34773 and previous config saved to /var/cache/conftool/dbconfig/20220915-092910-root.json
09:23 aqu@deploy1002: Started deploy [analytics/refinery@278c383] (hadoop-test): Regular analytics weekly train TEST [analytics/refinery@278c383]
09:14 marostegui@cumin1001: dbctl commit (dc=all): 'db2129 (re)pooling @ 10%: Repooling for warm up after upgrade', diff saved to https://phabricator.wikimedia.org/P34772 and previous config saved to /var/cache/conftool/dbconfig/20220915-091405-root.json
08:59 marostegui@cumin1001: dbctl commit (dc=all): 'db2129 (re)pooling @ 5%: Repooling for warm up after upgrade', diff saved to https://phabricator.wikimedia.org/P34770 and previous config saved to /var/cache/conftool/dbconfig/20220915-085900-root.json
08:49 apergos: UTC backport training window closed at lsat
08:46 btullis@cumin1001: END (PASS) - Cookbook sre.aqs.roll-restart (exit_code=0) for AQS aqs cluster: Roll restart of all AQS's nodejs daemons.
08:45 aqu@deploy1002: Started deploy [analytics/refinery@278c383]: Regular analytics weekly train [analytics/refinery@278c383]
08:43 marostegui@cumin1001: dbctl commit (dc=all): 'db2129 (re)pooling @ 3%: Repooling for warm up after upgrade', diff saved to https://phabricator.wikimedia.org/P34768 and previous config saved to /var/cache/conftool/dbconfig/20220915-084355-root.json
08:43 aqu: about to deploy analytics/refinery
08:40 marostegui@cumin1001: dbctl commit (dc=all): 'db2115 (re)pooling @ 100%: Repooling after upgrade', diff saved to https://phabricator.wikimedia.org/P34767 and previous config saved to /var/cache/conftool/dbconfig/20220915-084046-root.json
08:34 btullis@cumin1001: START - Cookbook sre.aqs.roll-restart for AQS aqs cluster: Roll restart of all AQS's nodejs daemons.
08:28 marostegui@cumin1001: dbctl commit (dc=all): 'db2129 (re)pooling @ 1%: Repooling for warm up after upgrade', diff saved to https://phabricator.wikimedia.org/P34766 and previous config saved to /var/cache/conftool/dbconfig/20220915-082851-root.json
08:25 marostegui@cumin1001: dbctl commit (dc=all): 'db2115 (re)pooling @ 75%: Repooling after upgrade', diff saved to https://phabricator.wikimedia.org/P34765 and previous config saved to /var/cache/conftool/dbconfig/20220915-082541-root.json
08:21 marostegui@cumin1001: dbctl commit (dc=all): 'db2105 (re)pooling @ 100%: Repooling for warm up after upgrade', diff saved to https://phabricator.wikimedia.org/P34764 and previous config saved to /var/cache/conftool/dbconfig/20220915-082112-root.json
08:16 marostegui@cumin1001: dbctl commit (dc=all): 'Depool db2129 T317850', diff saved to https://phabricator.wikimedia.org/P34763 and previous config saved to /var/cache/conftool/dbconfig/20220915-081627-root.json
08:15 marostegui@cumin1001: dbctl commit (dc=all): 'Promote db2114 to s6 codfw master T317850', diff saved to https://phabricator.wikimedia.org/P34762 and previous config saved to /var/cache/conftool/dbconfig/20220915-081517-marostegui.json
08:14 marostegui: Starting s6 codfw failover from db2129 to db2114 - T317850
08:10 marostegui@cumin1001: dbctl commit (dc=all): 'db2115 (re)pooling @ 50%: Repooling after upgrade', diff saved to https://phabricator.wikimedia.org/P34761 and previous config saved to /var/cache/conftool/dbconfig/20220915-081036-root.json
08:06 marostegui@cumin1001: dbctl commit (dc=all): 'db2105 (re)pooling @ 75%: Repooling for warm up after upgrade', diff saved to https://phabricator.wikimedia.org/P34760 and previous config saved to /var/cache/conftool/dbconfig/20220915-080607-root.json
08:01 marostegui@cumin1001: dbctl commit (dc=all): 'Depool db2114 from API T317850', diff saved to https://phabricator.wikimedia.org/P34759 and previous config saved to /var/cache/conftool/dbconfig/20220915-080157-root.json
08:01 marostegui@cumin1001: END (PASS) - Cookbook sre.hosts.downtime (exit_code=0) for 1:00:00 on 26 hosts with reason: Primary codfw s6 T317850
08:01 marostegui@cumin1001: dbctl commit (dc=all): 'Set db2114 with weight 0 T317850', diff saved to https://phabricator.wikimedia.org/P34758 and previous config saved to /var/cache/conftool/dbconfig/20220915-080122-root.json
08:01 marostegui@cumin1001: START - Cookbook sre.hosts.downtime for 1:00:00 on 26 hosts with reason: Primary codfw s6 T317850
07:55 marostegui@cumin1001: dbctl commit (dc=all): 'db2115 (re)pooling @ 25%: Repooling after upgrade', diff saved to https://phabricator.wikimedia.org/P34757 and previous config saved to /var/cache/conftool/dbconfig/20220915-075531-root.json
07:51 marostegui@cumin1001: dbctl commit (dc=all): 'db2105 (re)pooling @ 50%: Repooling for warm up after upgrade', diff saved to https://phabricator.wikimedia.org/P34756 and previous config saved to /var/cache/conftool/dbconfig/20220915-075102-root.json
07:40 marostegui@cumin1001: dbctl commit (dc=all): 'db2115 (re)pooling @ 10%: Repooling after upgrade', diff saved to https://phabricator.wikimedia.org/P34755 and previous config saved to /var/cache/conftool/dbconfig/20220915-074026-root.json
07:36 marostegui@cumin1001: dbctl commit (dc=all): 'db2105 (re)pooling @ 25%: Repooling for warm up after upgrade', diff saved to https://phabricator.wikimedia.org/P34754 and previous config saved to /var/cache/conftool/dbconfig/20220915-073557-root.json
07:25 marostegui@cumin1001: dbctl commit (dc=all): 'db2115 (re)pooling @ 5%: Repooling after upgrade', diff saved to https://phabricator.wikimedia.org/P34753 and previous config saved to /var/cache/conftool/dbconfig/20220915-072520-root.json
07:20 marostegui@cumin1001: dbctl commit (dc=all): 'db2105 (re)pooling @ 10%: Repooling for warm up after upgrade', diff saved to https://phabricator.wikimedia.org/P34752 and previous config saved to /var/cache/conftool/dbconfig/20220915-072053-root.json
07:17 marostegui@cumin1001: END (PASS) - Cookbook sre.hosts.downtime (exit_code=0) for 1:00:00 on db2151.codfw.wmnet with reason: reboot
07:17 marostegui@cumin1001: START - Cookbook sre.hosts.downtime for 1:00:00 on db2151.codfw.wmnet with reason: reboot
07:14 moritzm: installing zlib security updates
07:13 jmm@cumin2002: END (PASS) - Cookbook sre.misc-clusters.roll-restart-reboot-docker-registry (exit_code=0) rolling restart_daemons on A:docker-registry
07:11 jmm@cumin2002: START - Cookbook sre.misc-clusters.roll-restart-reboot-docker-registry rolling restart_daemons on A:docker-registry
07:10 marostegui@cumin1001: dbctl commit (dc=all): 'db2115 (re)pooling @ 3%: Repooling after upgrade', diff saved to https://phabricator.wikimedia.org/P34751 and previous config saved to /var/cache/conftool/dbconfig/20220915-071015-root.json
07:09 jmm@cumin2002: END (PASS) - Cookbook sre.misc-clusters.roll-restart-reboot-docker-registry (exit_code=0) rolling restart_daemons on A:docker-registry
07:06 jmm@cumin2002: START - Cookbook sre.misc-clusters.roll-restart-reboot-docker-registry rolling restart_daemons on A:docker-registry
07:05 marostegui@cumin1001: dbctl commit (dc=all): 'db2105 (re)pooling @ 5%: Repooling for warm up after upgrade', diff saved to https://phabricator.wikimedia.org/P34750 and previous config saved to /var/cache/conftool/dbconfig/20220915-070548-root.json
06:55 marostegui@cumin1001: dbctl commit (dc=all): 'db2115 (re)pooling @ 1%: Repooling after upgrade', diff saved to https://phabricator.wikimedia.org/P34749 and previous config saved to /var/cache/conftool/dbconfig/20220915-065510-root.json
06:50 marostegui@cumin1001: dbctl commit (dc=all): 'db2105 (re)pooling @ 3%: Repooling for warm up after upgrade', diff saved to https://phabricator.wikimedia.org/P34748 and previous config saved to /var/cache/conftool/dbconfig/20220915-065043-root.json
06:47 marostegui@cumin1001: dbctl commit (dc=all): 'Give some weight to db2096 T317842', diff saved to https://phabricator.wikimedia.org/P34747 and previous config saved to /var/cache/conftool/dbconfig/20220915-064750-marostegui.json
06:46 marostegui@cumin1001: dbctl commit (dc=all): 'Depool db2115 T317842', diff saved to https://phabricator.wikimedia.org/P34746 and previous config saved to /var/cache/conftool/dbconfig/20220915-064635-marostegui.json
06:45 marostegui@cumin1001: dbctl commit (dc=all): 'Promote db2096 to x1 primary and set section read-write T317842', diff saved to https://phabricator.wikimedia.org/P34745 and previous config saved to /var/cache/conftool/dbconfig/20220915-064525-root.json
06:44 marostegui: Starting x1 codfw failover from db2115 to db2096 - T317842
06:40 marostegui@cumin1001: END (PASS) - Cookbook sre.hosts.downtime (exit_code=0) for 1:00:00 on 10 hosts with reason: Primary switchover x1 T317842
06:40 marostegui@cumin1001: dbctl commit (dc=all): 'Set db2096 with weight 0 T317842', diff saved to https://phabricator.wikimedia.org/P34744 and previous config saved to /var/cache/conftool/dbconfig/20220915-064014-root.json
06:40 marostegui@cumin1001: START - Cookbook sre.hosts.downtime for 1:00:00 on 10 hosts with reason: Primary switchover x1 T317842
06:35 marostegui@cumin1001: dbctl commit (dc=all): 'db2105 (re)pooling @ 1%: Repooling for warm up after upgrade', diff saved to https://phabricator.wikimedia.org/P34743 and previous config saved to /var/cache/conftool/dbconfig/20220915-063538-root.json
06:14 marostegui@cumin1001: dbctl commit (dc=all): 'Depool db2105 T317839', diff saved to https://phabricator.wikimedia.org/P34742 and previous config saved to /var/cache/conftool/dbconfig/20220915-061421-root.json
06:13 marostegui@cumin1001: dbctl commit (dc=all): 'Promote db2127 to s3 codfw T317839', diff saved to https://phabricator.wikimedia.org/P34741 and previous config saved to /var/cache/conftool/dbconfig/20220915-061317-marostegui.json
06:12 marostegui: Starting s3 codfw failover from db2105 to db2127 - T317839
06:03 marostegui@cumin1001: dbctl commit (dc=all): 'Set db2127 with weight 0 T317839', diff saved to https://phabricator.wikimedia.org/P34740 and previous config saved to /var/cache/conftool/dbconfig/20220915-060307-root.json
06:02 marostegui@cumin1001: END (PASS) - Cookbook sre.hosts.downtime (exit_code=0) for 1:00:00 on 23 hosts with reason: Codfw switchover s3 T317839
06:02 marostegui@cumin1001: START - Cookbook sre.hosts.downtime for 1:00:00 on 23 hosts with reason: Codfw switchover s3 T317839
05:32 marostegui@cumin1001: END (ERROR) - Cookbook sre.hosts.downtime (exit_code=97) for 7 days, 0:00:00 on db1189.eqiad.wmnet with reason: down T317662
05:32 marostegui@cumin1001: START - Cookbook sre.hosts.downtime for 7 days, 0:00:00 on db1189.eqiad.wmnet with reason: down T317662
05:12 marostegui@cumin1001: END (PASS) - Cookbook sre.hosts.downtime (exit_code=0) for 7 days, 0:00:00 on db1189.eqiad.wmnet with reason: down T317662
05:12 marostegui@cumin1001: START - Cookbook sre.hosts.downtime for 7 days, 0:00:00 on db1189.eqiad.wmnet with reason: down T317662
2022-09-14
22:08 ladsgroup@cumin1001: dbctl commit (dc=all): 'Depooling db1190 (T314041)', diff saved to https://phabricator.wikimedia.org/P34739 and previous config saved to /var/cache/conftool/dbconfig/20220914-220822-ladsgroup.json
22:08 ladsgroup@cumin1001: END (PASS) - Cookbook sre.hosts.downtime (exit_code=0) for 1 day, 0:00:00 on db1190.eqiad.wmnet with reason: Maintenance
22:08 ladsgroup@cumin1001: START - Cookbook sre.hosts.downtime for 1 day, 0:00:00 on db1190.eqiad.wmnet with reason: Maintenance
22:08 ladsgroup@cumin1001: END (PASS) - Cookbook sre.hosts.downtime (exit_code=0) for 1 day, 0:00:00 on db1150.eqiad.wmnet with reason: Maintenance
22:07 ladsgroup@cumin1001: START - Cookbook sre.hosts.downtime for 1 day, 0:00:00 on db1150.eqiad.wmnet with reason: Maintenance
22:07 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db1149 (T314041)', diff saved to https://phabricator.wikimedia.org/P34738 and previous config saved to /var/cache/conftool/dbconfig/20220914-220744-ladsgroup.json
21:52 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db1149', diff saved to https://phabricator.wikimedia.org/P34737 and previous config saved to /var/cache/conftool/dbconfig/20220914-215238-ladsgroup.json
21:37 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db1149', diff saved to https://phabricator.wikimedia.org/P34736 and previous config saved to /var/cache/conftool/dbconfig/20220914-213732-ladsgroup.json
21:37 dduvall@deploy1002: Started deploy [phabricator/deployment@3137c92]: testing phabricator deployment to phab2002
21:36 dduvall: testing phabricator deployment to phab2002. should have no production impact (not serving traffic, no access to r/w db)
21:35 dduvall@deploy1002: Installation of scap version "4.19.1" completed for 561 hosts
21:35 dduvall@deploy1002: Installing scap version "4.19.1" for 561 hosts
21:22 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db1149 (T314041)', diff saved to https://phabricator.wikimedia.org/P34735 and previous config saved to /var/cache/conftool/dbconfig/20220914-212225-ladsgroup.json
18:59 dancy@deploy1002: rebuilt and synchronized wikiversions files: group0 wikis to 1.40.0-wmf.1 refs T314190
18:50 ebernhardson@deploy1002: Finished deploy [wikimedia/discovery/analytics@e358893]: drop-snapshots: tables are partitioned by wiki (duration: 02m 05s)
18:48 ebernhardson@deploy1002: Started deploy [wikimedia/discovery/analytics@e358893]: drop-snapshots: tables are partitioned by wiki
16:05 volans@cumin1001: END (PASS) - Cookbook sre.deploy.python-code (exit_code=0) homer to cumin2002.codfw.wmnet,cumin1001.eqiad.wmnet with reason: Release v0.6.1 - volans@cumin1001
16:04 volans@cumin1001: START - Cookbook sre.deploy.python-code homer to cumin2002.codfw.wmnet,cumin1001.eqiad.wmnet with reason: Release v0.6.1 - volans@cumin1001
15:58 cwhite@cumin2002: END (PASS) - Cookbook sre.dns.wipe-cache (exit_code=0) logstash2024.codfw.wmnet on all recursors
15:58 cwhite@cumin2002: START - Cookbook sre.dns.wipe-cache logstash2024.codfw.wmnet on all recursors
15:58 cwhite@cumin2002: END (PASS) - Cookbook sre.dns.wipe-cache (exit_code=0) logstash2002.codfw.wmnet on all recursors
15:58 cwhite@cumin2002: START - Cookbook sre.dns.wipe-cache logstash2002.codfw.wmnet on all recursors
15:58 cwhite@cumin2002: END (PASS) - Cookbook sre.dns.wipe-cache (exit_code=0) logstash1026.eqiad.wmnet on all recursors
15:57 cwhite@cumin2002: START - Cookbook sre.dns.wipe-cache logstash1026.eqiad.wmnet on all recursors
15:57 cwhite@cumin2002: END (PASS) - Cookbook sre.dns.wipe-cache (exit_code=0) logstash1029.eqiad.wmnet on all recursors
15:57 cwhite@cumin2002: START - Cookbook sre.dns.wipe-cache logstash1029.eqiad.wmnet on all recursors
15:57 cwhite@cumin2002: END (PASS) - Cookbook sre.dns.wipe-cache (exit_code=0) logstash1028.eqiad.wmnet on all recursors
15:57 cwhite@cumin2002: START - Cookbook sre.dns.wipe-cache logstash1028.eqiad.wmnet on all recursors
15:57 cwhite@cumin2002: END (PASS) - Cookbook sre.dns.wipe-cache (exit_code=0) logstash1027.eqiad.wmnet on all recursors
15:57 cwhite@cumin2002: START - Cookbook sre.dns.wipe-cache logstash1027.eqiad.wmnet on all recursors
15:55 cwhite@cumin2002: END (PASS) - Cookbook sre.dns.wipe-cache (exit_code=0) logstash2001.codfw.wmnet on all recursors
15:55 cwhite@cumin2002: START - Cookbook sre.dns.wipe-cache logstash2001.codfw.wmnet on all recursors
14:59 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db2177 (T314041)', diff saved to https://phabricator.wikimedia.org/P34732 and previous config saved to /var/cache/conftool/dbconfig/20220914-145956-ladsgroup.json
14:44 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db2177', diff saved to https://phabricator.wikimedia.org/P34731 and previous config saved to /var/cache/conftool/dbconfig/20220914-144449-ladsgroup.json
14:29 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db2177', diff saved to https://phabricator.wikimedia.org/P34730 and previous config saved to /var/cache/conftool/dbconfig/20220914-142941-ladsgroup.json
14:14 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db2177 (T314041)', diff saved to https://phabricator.wikimedia.org/P34729 and previous config saved to /var/cache/conftool/dbconfig/20220914-141434-ladsgroup.json
12:54 jayme: imported rsyslog 8.2208.0-1~bpo11+1 into bullseye-wikimedia component/rsyslog-k8s - T289766
11:59 ladsgroup@cumin1001: END (PASS) - Cookbook sre.hosts.downtime (exit_code=0) for 1 day, 0:00:00 on db1189.eqiad.wmnet with reason: Maintenance
11:59 ladsgroup@cumin1001: START - Cookbook sre.hosts.downtime for 1 day, 0:00:00 on db1189.eqiad.wmnet with reason: Maintenance
11:59 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db1179 (T314041)', diff saved to https://phabricator.wikimedia.org/P34725 and previous config saved to /var/cache/conftool/dbconfig/20220914-115920-ladsgroup.json
11:49 cmooney@cumin1001: END (PASS) - Cookbook sre.hosts.remove-downtime (exit_code=0) for cr2-eqdfw,cr2-eqdfw IPv6
11:49 cmooney@cumin1001: START - Cookbook sre.hosts.remove-downtime for cr2-eqdfw,cr2-eqdfw IPv6
11:44 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db1179', diff saved to https://phabricator.wikimedia.org/P34723 and previous config saved to /var/cache/conftool/dbconfig/20220914-114413-ladsgroup.json
11:29 topranks: rebooting cr2-eqdfw to complete upgrade
11:29 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db1179', diff saved to https://phabricator.wikimedia.org/P34721 and previous config saved to /var/cache/conftool/dbconfig/20220914-112907-ladsgroup.json
11:14 topranks: Shutting down internet transit and peering on cr2-eqdfw in advance of upgrade reboot
11:14 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db1179 (T314041)', diff saved to https://phabricator.wikimedia.org/P34719 and previous config saved to /var/cache/conftool/dbconfig/20220914-111400-ladsgroup.json
11:02 cmooney@cumin1001: END (PASS) - Cookbook sre.hosts.downtime (exit_code=0) for 2:00:00 on cr2-eqdfw,cr2-eqdfw IPv6 with reason: router upgrade
11:02 cmooney@cumin1001: START - Cookbook sre.hosts.downtime for 2:00:00 on cr2-eqdfw,cr2-eqdfw IPv6 with reason: router upgrade
11:01 topranks: Prepping to upgrade JunOS on cr2-eqdfw. Adjusting OSPF costs to force traffic via alternate POPs.
10:38 marostegui@cumin1001: dbctl commit (dc=all): 'es1024 (re)pooling @ 100%: Repooling for warm up after upgrade', diff saved to https://phabricator.wikimedia.org/P34717 and previous config saved to /var/cache/conftool/dbconfig/20220914-103810-root.json
10:23 marostegui@cumin1001: dbctl commit (dc=all): 'es1024 (re)pooling @ 75%: Repooling for warm up after upgrade', diff saved to https://phabricator.wikimedia.org/P34715 and previous config saved to /var/cache/conftool/dbconfig/20220914-102305-root.json
10:18 moritzm: import routinator 0.11.3-1bullseye to thirdparty/routinator
10:08 marostegui@cumin1001: dbctl commit (dc=all): 'es1024 (re)pooling @ 50%: Repooling for warm up after upgrade', diff saved to https://phabricator.wikimedia.org/P34714 and previous config saved to /var/cache/conftool/dbconfig/20220914-100800-root.json
09:52 marostegui@cumin1001: dbctl commit (dc=all): 'es1024 (re)pooling @ 25%: Repooling for warm up after upgrade', diff saved to https://phabricator.wikimedia.org/P34713 and previous config saved to /var/cache/conftool/dbconfig/20220914-095255-root.json
09:37 marostegui@cumin1001: dbctl commit (dc=all): 'es1024 (re)pooling @ 10%: Repooling for warm up after upgrade', diff saved to https://phabricator.wikimedia.org/P34712 and previous config saved to /var/cache/conftool/dbconfig/20220914-093750-root.json
09:27 moritzm: installing zlib/libxslt security updates on buster
09:26 ladsgroup@cumin1001: dbctl commit (dc=all): 'Depooling db2177 (T314041)', diff saved to https://phabricator.wikimedia.org/P34711 and previous config saved to /var/cache/conftool/dbconfig/20220914-092620-ladsgroup.json
09:26 ladsgroup@cumin1001: END (PASS) - Cookbook sre.hosts.downtime (exit_code=0) for 1 day, 0:00:00 on db2177.codfw.wmnet with reason: Maintenance
09:26 ladsgroup@cumin1001: START - Cookbook sre.hosts.downtime for 1 day, 0:00:00 on db2177.codfw.wmnet with reason: Maintenance
09:26 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db2156 (T314041)', diff saved to https://phabricator.wikimedia.org/P34710 and previous config saved to /var/cache/conftool/dbconfig/20220914-092558-ladsgroup.json
09:22 marostegui@cumin1001: dbctl commit (dc=all): 'es1024 (re)pooling @ 5%: Repooling for warm up after upgrade', diff saved to https://phabricator.wikimedia.org/P34709 and previous config saved to /var/cache/conftool/dbconfig/20220914-092245-root.json
09:15 ladsgroup@cumin1001: END (PASS) - Cookbook sre.hosts.downtime (exit_code=0) for 1 day, 0:00:00 on db2094.codfw.wmnet with reason: Maintenance
09:15 ladsgroup@cumin1001: START - Cookbook sre.hosts.downtime for 1 day, 0:00:00 on db2094.codfw.wmnet with reason: Maintenance
09:12 ladsgroup@cumin1001: END (PASS) - Cookbook sre.hosts.downtime (exit_code=0) for 1 day, 0:00:00 on db2094.codfw.wmnet with reason: Maintenance
09:12 ladsgroup@cumin1001: START - Cookbook sre.hosts.downtime for 1 day, 0:00:00 on db2094.codfw.wmnet with reason: Maintenance
09:10 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db2156', diff saved to https://phabricator.wikimedia.org/P34708 and previous config saved to /var/cache/conftool/dbconfig/20220914-091052-ladsgroup.json
09:07 marostegui@cumin1001: dbctl commit (dc=all): 'es1024 (re)pooling @ 3%: Repooling for warm up after upgrade', diff saved to https://phabricator.wikimedia.org/P34707 and previous config saved to /var/cache/conftool/dbconfig/20220914-090740-root.json
09:07 jmm@cumin2002: END (PASS) - Cookbook sre.wdqs.restart-nginx (exit_code=0) rolling restart_daemons on A:wcqs-public
09:05 jmm@cumin2002: START - Cookbook sre.wdqs.restart-nginx rolling restart_daemons on A:wcqs-public
09:01 jmm@cumin2002: END (PASS) - Cookbook sre.wdqs.restart-nginx (exit_code=0) rolling restart_daemons on A:wdqs-all
08:55 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db2156', diff saved to https://phabricator.wikimedia.org/P34706 and previous config saved to /var/cache/conftool/dbconfig/20220914-085545-ladsgroup.json
08:52 marostegui@cumin1001: dbctl commit (dc=all): 'es1024 (re)pooling @ 1%: Repooling for warm up after upgrade', diff saved to https://phabricator.wikimedia.org/P34705 and previous config saved to /var/cache/conftool/dbconfig/20220914-085235-root.json
08:50 jmm@cumin2002: START - Cookbook sre.wdqs.restart-nginx rolling restart_daemons on A:wdqs-all
08:49 jmm@cumin2002: END (PASS) - Cookbook sre.wdqs.restart-nginx (exit_code=0) rolling restart_daemons on A:wdqs-test
08:49 jmm@cumin2002: START - Cookbook sre.wdqs.restart-nginx rolling restart_daemons on A:wdqs-test
08:40 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db2156 (T314041)', diff saved to https://phabricator.wikimedia.org/P34704 and previous config saved to /var/cache/conftool/dbconfig/20220914-084039-ladsgroup.json
08:38 jmm@cumin2002: END (PASS) - Cookbook sre.wdqs.restart-nginx (exit_code=0) rolling restart on A:wdqs-test
08:38 jmm@cumin2002: START - Cookbook sre.wdqs.restart-nginx rolling restart on A:wdqs-test
07:46 marostegui@cumin1001: dbctl commit (dc=all): 'Set es1023 with weight 0 T317739', diff saved to https://phabricator.wikimedia.org/P34701 and previous config saved to /var/cache/conftool/dbconfig/20220914-074617-marostegui.json
07:44 marostegui@cumin1001: END (PASS) - Cookbook sre.hosts.downtime (exit_code=0) for 1:00:00 on 6 hosts with reason: Primary switchover es5 T317739
07:44 marostegui@cumin1001: START - Cookbook sre.hosts.downtime for 1:00:00 on 6 hosts with reason: Primary switchover es5 T317739
07:42 marostegui@cumin1001: dbctl commit (dc=all): 'db2123 (re)pooling @ 100%: Repooling for warm up after upgrade', diff saved to https://phabricator.wikimedia.org/P34700 and previous config saved to /var/cache/conftool/dbconfig/20220914-074248-root.json
07:27 marostegui@cumin1001: dbctl commit (dc=all): 'db2123 (re)pooling @ 75%: Repooling for warm up after upgrade', diff saved to https://phabricator.wikimedia.org/P34699 and previous config saved to /var/cache/conftool/dbconfig/20220914-072743-root.json
07:12 marostegui@cumin1001: dbctl commit (dc=all): 'db2123 (re)pooling @ 50%: Repooling for warm up after upgrade', diff saved to https://phabricator.wikimedia.org/P34698 and previous config saved to /var/cache/conftool/dbconfig/20220914-071238-root.json
06:57 marostegui@cumin1001: dbctl commit (dc=all): 'db2123 (re)pooling @ 25%: Repooling for warm up after upgrade', diff saved to https://phabricator.wikimedia.org/P34697 and previous config saved to /var/cache/conftool/dbconfig/20220914-065733-root.json
06:43 ladsgroup@cumin1001: dbctl commit (dc=all): 'Depooling db1179 (T314041)', diff saved to https://phabricator.wikimedia.org/P34696 and previous config saved to /var/cache/conftool/dbconfig/20220914-064330-ladsgroup.json
06:43 ladsgroup@cumin1001: END (PASS) - Cookbook sre.hosts.downtime (exit_code=0) for 1 day, 0:00:00 on db1179.eqiad.wmnet with reason: Maintenance
06:43 ladsgroup@cumin1001: START - Cookbook sre.hosts.downtime for 1 day, 0:00:00 on db1179.eqiad.wmnet with reason: Maintenance
06:43 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db1175 (T314041)', diff saved to https://phabricator.wikimedia.org/P34695 and previous config saved to /var/cache/conftool/dbconfig/20220914-064309-ladsgroup.json
06:42 marostegui@cumin1001: dbctl commit (dc=all): 'db2123 (re)pooling @ 10%: Repooling for warm up after upgrade', diff saved to https://phabricator.wikimedia.org/P34694 and previous config saved to /var/cache/conftool/dbconfig/20220914-064228-root.json
06:38 elukey: restart kafka on kafka-logging2003 to pick up the new PKI TLS settings
06:33 elukey@cumin1001: END (PASS) - Cookbook sre.hosts.downtime (exit_code=0) for 0:20:00 on kafka-logging2003.codfw.wmnet with reason: Kafka PKI upgrade
06:33 elukey@cumin1001: START - Cookbook sre.hosts.downtime for 0:20:00 on kafka-logging2003.codfw.wmnet with reason: Kafka PKI upgrade
06:28 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db1175', diff saved to https://phabricator.wikimedia.org/P34693 and previous config saved to /var/cache/conftool/dbconfig/20220914-062802-ladsgroup.json
06:27 marostegui@cumin1001: dbctl commit (dc=all): 'db2123 (re)pooling @ 5%: Repooling for warm up after upgrade', diff saved to https://phabricator.wikimedia.org/P34692 and previous config saved to /var/cache/conftool/dbconfig/20220914-062723-root.json
06:12 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db1175', diff saved to https://phabricator.wikimedia.org/P34691 and previous config saved to /var/cache/conftool/dbconfig/20220914-061256-ladsgroup.json
06:11 marostegui@cumin1001: END (PASS) - Cookbook sre.hosts.downtime (exit_code=0) for 1:00:00 on db2123.codfw.wmnet with reason: down
06:11 marostegui@cumin1001: START - Cookbook sre.hosts.downtime for 1:00:00 on db2123.codfw.wmnet with reason: down
06:09 marostegui@cumin1001: dbctl commit (dc=all): 'Depool db2123 T317735', diff saved to https://phabricator.wikimedia.org/P34690 and previous config saved to /var/cache/conftool/dbconfig/20220914-060913-root.json
06:08 marostegui@cumin1001: dbctl commit (dc=all): 'Promote db2113 to s5 codfw primary T317735', diff saved to https://phabricator.wikimedia.org/P34689 and previous config saved to /var/cache/conftool/dbconfig/20220914-060807-marostegui.json
05:57 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db1175 (T314041)', diff saved to https://phabricator.wikimedia.org/P34688 and previous config saved to /var/cache/conftool/dbconfig/20220914-055749-ladsgroup.json
05:51 marostegui@cumin1001: dbctl commit (dc=all): 'Set db2113 with weight 0 T317735', diff saved to https://phabricator.wikimedia.org/P34687 and previous config saved to /var/cache/conftool/dbconfig/20220914-055156-marostegui.json
05:51 marostegui@cumin1001: END (PASS) - Cookbook sre.hosts.downtime (exit_code=0) for 1:00:00 on 25 hosts with reason: Primary switchover s5 T317735
05:51 marostegui@cumin1001: START - Cookbook sre.hosts.downtime for 1:00:00 on 25 hosts with reason: Primary switchover s5 T317735
05:25 ladsgroup@cumin1001: dbctl commit (dc=all): 'Depooling db1149 (T314041)', diff saved to https://phabricator.wikimedia.org/P34686 and previous config saved to /var/cache/conftool/dbconfig/20220914-052510-ladsgroup.json
05:25 ladsgroup@cumin1001: END (PASS) - Cookbook sre.hosts.downtime (exit_code=0) for 1 day, 0:00:00 on db1149.eqiad.wmnet with reason: Maintenance
05:24 ladsgroup@cumin1001: START - Cookbook sre.hosts.downtime for 1 day, 0:00:00 on db1149.eqiad.wmnet with reason: Maintenance
05:24 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db1148 (T314041)', diff saved to https://phabricator.wikimedia.org/P34685 and previous config saved to /var/cache/conftool/dbconfig/20220914-052448-ladsgroup.json
05:09 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db1148', diff saved to https://phabricator.wikimedia.org/P34684 and previous config saved to /var/cache/conftool/dbconfig/20220914-050942-ladsgroup.json
04:54 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db1148', diff saved to https://phabricator.wikimedia.org/P34683 and previous config saved to /var/cache/conftool/dbconfig/20220914-045435-ladsgroup.json
04:39 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db1148 (T314041)', diff saved to https://phabricator.wikimedia.org/P34682 and previous config saved to /var/cache/conftool/dbconfig/20220914-043929-ladsgroup.json
03:56 ladsgroup@cumin1001: dbctl commit (dc=all): 'Depooling db2156 (T314041)', diff saved to https://phabricator.wikimedia.org/P34681 and previous config saved to /var/cache/conftool/dbconfig/20220914-035624-ladsgroup.json
03:56 ladsgroup@cumin1001: END (PASS) - Cookbook sre.hosts.downtime (exit_code=0) for 2 days, 0:00:00 on db2094.codfw.wmnet with reason: Maintenance
03:56 ladsgroup@cumin1001: START - Cookbook sre.hosts.downtime for 2 days, 0:00:00 on db2094.codfw.wmnet with reason: Maintenance
03:56 ladsgroup@cumin1001: END (PASS) - Cookbook sre.hosts.downtime (exit_code=0) for 1 day, 0:00:00 on db2156.codfw.wmnet with reason: Maintenance
03:55 ladsgroup@cumin1001: START - Cookbook sre.hosts.downtime for 1 day, 0:00:00 on db2156.codfw.wmnet with reason: Maintenance
03:55 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db2149 (T314041)', diff saved to https://phabricator.wikimedia.org/P34680 and previous config saved to /var/cache/conftool/dbconfig/20220914-035546-ladsgroup.json
03:40 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db2149', diff saved to https://phabricator.wikimedia.org/P34679 and previous config saved to /var/cache/conftool/dbconfig/20220914-034040-ladsgroup.json
03:39 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db2182 (T314041)', diff saved to https://phabricator.wikimedia.org/P34678 and previous config saved to /var/cache/conftool/dbconfig/20220914-033921-ladsgroup.json
03:25 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db2149', diff saved to https://phabricator.wikimedia.org/P34677 and previous config saved to /var/cache/conftool/dbconfig/20220914-032533-ladsgroup.json
03:24 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db2182', diff saved to https://phabricator.wikimedia.org/P34676 and previous config saved to /var/cache/conftool/dbconfig/20220914-032415-ladsgroup.json
03:10 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db2149 (T314041)', diff saved to https://phabricator.wikimedia.org/P34675 and previous config saved to /var/cache/conftool/dbconfig/20220914-031027-ladsgroup.json
03:09 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db2182', diff saved to https://phabricator.wikimedia.org/P34674 and previous config saved to /var/cache/conftool/dbconfig/20220914-030908-ladsgroup.json
02:54 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db2182 (T314041)', diff saved to https://phabricator.wikimedia.org/P34673 and previous config saved to /var/cache/conftool/dbconfig/20220914-025402-ladsgroup.json
01:32 ladsgroup@cumin1001: dbctl commit (dc=all): 'Depooling db1175 (T314041)', diff saved to https://phabricator.wikimedia.org/P34672 and previous config saved to /var/cache/conftool/dbconfig/20220914-013204-ladsgroup.json
01:31 ladsgroup@cumin1001: END (PASS) - Cookbook sre.hosts.downtime (exit_code=0) for 1 day, 0:00:00 on db1175.eqiad.wmnet with reason: Maintenance
01:31 ladsgroup@cumin1001: START - Cookbook sre.hosts.downtime for 1 day, 0:00:00 on db1175.eqiad.wmnet with reason: Maintenance
01:31 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db1166 (T314041)', diff saved to https://phabricator.wikimedia.org/P34671 and previous config saved to /var/cache/conftool/dbconfig/20220914-013143-ladsgroup.json
01:18 bking@cumin1001: END (PASS) - Cookbook sre.elasticsearch.rolling-operation (exit_code=0) Operation.UPGRADE (3 nodes at a time) for ElasticSearch cluster search_eqiad: elastic 6.8 -> 7.10 - bking@cumin1001 - T317686
01:16 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db1166', diff saved to https://phabricator.wikimedia.org/P34670 and previous config saved to /var/cache/conftool/dbconfig/20220914-011637-ladsgroup.json
01:14 ejegg: disabled delete_deleted_contacts job (will take effect when current job ends)
01:01 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db1166', diff saved to https://phabricator.wikimedia.org/P34669 and previous config saved to /var/cache/conftool/dbconfig/20220914-010130-ladsgroup.json
00:46 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db1166 (T314041)', diff saved to https://phabricator.wikimedia.org/P34668 and previous config saved to /var/cache/conftool/dbconfig/20220914-004624-ladsgroup.json
2022-09-13
23:46 ladsgroup@cumin1001: dbctl commit (dc=all): 'Depooling db1166 (T314041)', diff saved to https://phabricator.wikimedia.org/P34667 and previous config saved to /var/cache/conftool/dbconfig/20220913-234607-ladsgroup.json
23:46 ladsgroup@cumin1001: END (PASS) - Cookbook sre.hosts.downtime (exit_code=0) for 1 day, 0:00:00 on db1166.eqiad.wmnet with reason: Maintenance
23:45 ladsgroup@cumin1001: START - Cookbook sre.hosts.downtime for 1 day, 0:00:00 on db1166.eqiad.wmnet with reason: Maintenance
23:45 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db1157 (T314041)', diff saved to https://phabricator.wikimedia.org/P34666 and previous config saved to /var/cache/conftool/dbconfig/20220913-234546-ladsgroup.json
23:30 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db1157', diff saved to https://phabricator.wikimedia.org/P34665 and previous config saved to /var/cache/conftool/dbconfig/20220913-233039-ladsgroup.json
23:15 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db1157', diff saved to https://phabricator.wikimedia.org/P34664 and previous config saved to /var/cache/conftool/dbconfig/20220913-231533-ladsgroup.json
23:13 ladsgroup@cumin1001: END (PASS) - Cookbook sre.hosts.downtime (exit_code=0) for 1 day, 0:00:00 on dbstore1003.eqiad.wmnet with reason: Maintenance
23:13 ladsgroup@cumin1001: START - Cookbook sre.hosts.downtime for 1 day, 0:00:00 on dbstore1003.eqiad.wmnet with reason: Maintenance
23:12 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db1202 (T314041)', diff saved to https://phabricator.wikimedia.org/P34663 and previous config saved to /var/cache/conftool/dbconfig/20220913-231257-ladsgroup.json
23:03 ladsgroup@cumin1001: dbctl commit (dc=all): 'Depooling db2182 (T314041)', diff saved to https://phabricator.wikimedia.org/P34662 and previous config saved to /var/cache/conftool/dbconfig/20220913-230317-ladsgroup.json
23:03 ladsgroup@cumin1001: END (PASS) - Cookbook sre.hosts.downtime (exit_code=0) for 1 day, 0:00:00 on db2182.codfw.wmnet with reason: Maintenance
23:02 ladsgroup@cumin1001: START - Cookbook sre.hosts.downtime for 1 day, 0:00:00 on db2182.codfw.wmnet with reason: Maintenance
23:02 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db2169:3317 (T314041)', diff saved to https://phabricator.wikimedia.org/P34661 and previous config saved to /var/cache/conftool/dbconfig/20220913-230255-ladsgroup.json
23:00 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db1157 (T314041)', diff saved to https://phabricator.wikimedia.org/P34660 and previous config saved to /var/cache/conftool/dbconfig/20220913-230026-ladsgroup.json
22:57 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db1202', diff saved to https://phabricator.wikimedia.org/P34659 and previous config saved to /var/cache/conftool/dbconfig/20220913-225750-ladsgroup.json
22:47 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db2169:3317', diff saved to https://phabricator.wikimedia.org/P34658 and previous config saved to /var/cache/conftool/dbconfig/20220913-224749-ladsgroup.json
22:42 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db1202', diff saved to https://phabricator.wikimedia.org/P34657 and previous config saved to /var/cache/conftool/dbconfig/20220913-224244-ladsgroup.json
22:32 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db2169:3317', diff saved to https://phabricator.wikimedia.org/P34656 and previous config saved to /var/cache/conftool/dbconfig/20220913-223241-ladsgroup.json
22:30 ladsgroup@cumin1001: dbctl commit (dc=all): 'Depooling db2149 (T314041)', diff saved to https://phabricator.wikimedia.org/P34655 and previous config saved to /var/cache/conftool/dbconfig/20220913-223025-ladsgroup.json
22:30 ladsgroup@cumin1001: END (PASS) - Cookbook sre.hosts.downtime (exit_code=0) for 1 day, 0:00:00 on db2149.codfw.wmnet with reason: Maintenance
22:30 ladsgroup@cumin1001: START - Cookbook sre.hosts.downtime for 1 day, 0:00:00 on db2149.codfw.wmnet with reason: Maintenance
22:27 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db1202 (T314041)', diff saved to https://phabricator.wikimedia.org/P34654 and previous config saved to /var/cache/conftool/dbconfig/20220913-222738-ladsgroup.json
22:17 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db2169:3317 (T314041)', diff saved to https://phabricator.wikimedia.org/P34653 and previous config saved to /var/cache/conftool/dbconfig/20220913-221734-ladsgroup.json
20:09 cjming@deploy1002: cjming and aishik: Backport for add tagline and update wordmark in ptwikinews (T313174) synced to the testservers: mwdebug2001.codfw.wmnet, mwdebug2002.codfw.wmnet, mwdebug1001.eqiad.wmnet, mwdebug1002.eqiad.wmnet
20:03 ladsgroup@cumin1001: dbctl commit (dc=all): 'Depooling db1157 (T314041)', diff saved to https://phabricator.wikimedia.org/P34652 and previous config saved to /var/cache/conftool/dbconfig/20220913-200344-ladsgroup.json
20:03 ladsgroup@cumin1001: END (PASS) - Cookbook sre.hosts.downtime (exit_code=0) for 1 day, 0:00:00 on db1157.eqiad.wmnet with reason: Maintenance
20:03 ladsgroup@cumin1001: START - Cookbook sre.hosts.downtime for 1 day, 0:00:00 on db1157.eqiad.wmnet with reason: Maintenance
20:02 ladsgroup@cumin1001: dbctl commit (dc=all): 'Depooling db1202 (T314041)', diff saved to https://phabricator.wikimedia.org/P34651 and previous config saved to /var/cache/conftool/dbconfig/20220913-200214-ladsgroup.json
20:02 ladsgroup@cumin1001: END (PASS) - Cookbook sre.hosts.downtime (exit_code=0) for 1 day, 0:00:00 on db1202.eqiad.wmnet with reason: Maintenance
20:01 ladsgroup@cumin1001: START - Cookbook sre.hosts.downtime for 1 day, 0:00:00 on db1202.eqiad.wmnet with reason: Maintenance
20:01 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db1194 (T314041)', diff saved to https://phabricator.wikimedia.org/P34650 and previous config saved to /var/cache/conftool/dbconfig/20220913-200152-ladsgroup.json
19:55 bking@cumin1001: START - Cookbook sre.elasticsearch.rolling-operation Operation.UPGRADE (3 nodes at a time) for ElasticSearch cluster search_eqiad: elastic 6.8 -> 7.10 - bking@cumin1001 - T317686
19:46 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db1194', diff saved to https://phabricator.wikimedia.org/P34649 and previous config saved to /var/cache/conftool/dbconfig/20220913-194645-ladsgroup.json
19:31 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db1194', diff saved to https://phabricator.wikimedia.org/P34648 and previous config saved to /var/cache/conftool/dbconfig/20220913-193139-ladsgroup.json
19:19 bking@cumin1001: END (ERROR) - Cookbook sre.elasticsearch.rolling-operation (exit_code=97) Operation.UPGRADE (3 nodes at a time) for ElasticSearch cluster search_eqiad: elastic 6.8 -> 7.10 - bking@cumin1001 - T317686
19:16 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db1194 (T314041)', diff saved to https://phabricator.wikimedia.org/P34647 and previous config saved to /var/cache/conftool/dbconfig/20220913-191632-ladsgroup.json
19:01 bking@cumin1001: START - Cookbook sre.elasticsearch.rolling-operation Operation.UPGRADE (3 nodes at a time) for ElasticSearch cluster search_eqiad: elastic 6.8 -> 7.10 - bking@cumin1001 - T317686
18:47 bking@cumin1001: END (FAIL) - Cookbook sre.elasticsearch.rolling-operation (exit_code=99) Operation.UPGRADE (3 nodes at a time) for ElasticSearch cluster search_eqiad: elastic 6.8 -> 7.10 - bking@cumin1001 - T317686
18:46 bking@cumin1001: START - Cookbook sre.elasticsearch.rolling-operation Operation.UPGRADE (3 nodes at a time) for ElasticSearch cluster search_eqiad: elastic 6.8 -> 7.10 - bking@cumin1001 - T317686
18:33 ladsgroup@cumin1001: dbctl commit (dc=all): 'Depooling db2169:3317 (T314041)', diff saved to https://phabricator.wikimedia.org/P34646 and previous config saved to /var/cache/conftool/dbconfig/20220913-183259-ladsgroup.json
18:32 ladsgroup@cumin1001: END (PASS) - Cookbook sre.hosts.downtime (exit_code=0) for 1 day, 0:00:00 on db2169.codfw.wmnet with reason: Maintenance
18:32 ladsgroup@cumin1001: START - Cookbook sre.hosts.downtime for 1 day, 0:00:00 on db2169.codfw.wmnet with reason: Maintenance
18:32 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db2168:3317 (T314041)', diff saved to https://phabricator.wikimedia.org/P34645 and previous config saved to /var/cache/conftool/dbconfig/20220913-183238-ladsgroup.json
18:28 TheresNoTime: deploying a beta cluster only config change, T317417
18:17 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db2168:3317', diff saved to https://phabricator.wikimedia.org/P34644 and previous config saved to /var/cache/conftool/dbconfig/20220913-181731-ladsgroup.json
18:02 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db2168:3317', diff saved to https://phabricator.wikimedia.org/P34643 and previous config saved to /var/cache/conftool/dbconfig/20220913-180225-ladsgroup.json
17:47 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db2168:3317 (T314041)', diff saved to https://phabricator.wikimedia.org/P34642 and previous config saved to /var/cache/conftool/dbconfig/20220913-174718-ladsgroup.json
17:43 volans@cumin1001: END (PASS) - Cookbook sre.deploy.python-code (exit_code=0) homer to cumin2002.codfw.wmnet,cumin1001.eqiad.wmnet with reason: Upgrade wmf-netbox plugin - volans@cumin1001
17:41 volans@cumin1001: START - Cookbook sre.deploy.python-code homer to cumin2002.codfw.wmnet,cumin1001.eqiad.wmnet with reason: Upgrade wmf-netbox plugin - volans@cumin1001
17:37 ladsgroup@cumin1001: END (PASS) - Cookbook sre.hosts.downtime (exit_code=0) for 1 day, 0:00:00 on db2139.codfw.wmnet with reason: Maintenance
17:37 ladsgroup@cumin1001: START - Cookbook sre.hosts.downtime for 1 day, 0:00:00 on db2139.codfw.wmnet with reason: Maintenance
17:37 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db2127 (T314041)', diff saved to https://phabricator.wikimedia.org/P34640 and previous config saved to /var/cache/conftool/dbconfig/20220913-173721-ladsgroup.json
17:32 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db2103 (T312863)', diff saved to https://phabricator.wikimedia.org/P34639 and previous config saved to /var/cache/conftool/dbconfig/20220913-173254-ladsgroup.json
17:22 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db2127', diff saved to https://phabricator.wikimedia.org/P34638 and previous config saved to /var/cache/conftool/dbconfig/20220913-172215-ladsgroup.json
17:17 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db2103', diff saved to https://phabricator.wikimedia.org/P34637 and previous config saved to /var/cache/conftool/dbconfig/20220913-171747-ladsgroup.json
17:07 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db2127', diff saved to https://phabricator.wikimedia.org/P34636 and previous config saved to /var/cache/conftool/dbconfig/20220913-170708-ladsgroup.json
17:02 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db2103', diff saved to https://phabricator.wikimedia.org/P34635 and previous config saved to /var/cache/conftool/dbconfig/20220913-170241-ladsgroup.json
16:56 ejegg: updated fundraising CiviCRM from efbbcb57 to d91b4a2c
16:52 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db2127 (T314041)', diff saved to https://phabricator.wikimedia.org/P34634 and previous config saved to /var/cache/conftool/dbconfig/20220913-165202-ladsgroup.json
16:51 ladsgroup@cumin1001: dbctl commit (dc=all): 'Depooling db1194 (T314041)', diff saved to https://phabricator.wikimedia.org/P34633 and previous config saved to /var/cache/conftool/dbconfig/20220913-165117-ladsgroup.json
16:51 ladsgroup@cumin1001: END (PASS) - Cookbook sre.hosts.downtime (exit_code=0) for 1 day, 0:00:00 on db1194.eqiad.wmnet with reason: Maintenance
16:51 ladsgroup@cumin1001: START - Cookbook sre.hosts.downtime for 1 day, 0:00:00 on db1194.eqiad.wmnet with reason: Maintenance
16:50 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db1191 (T314041)', diff saved to https://phabricator.wikimedia.org/P34632 and previous config saved to /var/cache/conftool/dbconfig/20220913-165056-ladsgroup.json
16:47 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db2103 (T312863)', diff saved to https://phabricator.wikimedia.org/P34631 and previous config saved to /var/cache/conftool/dbconfig/20220913-164734-ladsgroup.json
16:35 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db1191', diff saved to https://phabricator.wikimedia.org/P34630 and previous config saved to /var/cache/conftool/dbconfig/20220913-163549-ladsgroup.json
16:20 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db1191', diff saved to https://phabricator.wikimedia.org/P34629 and previous config saved to /var/cache/conftool/dbconfig/20220913-162043-ladsgroup.json
16:13 godog: add 200G to prometheus/eqiad instance ops
16:09 ladsgroup@cumin1001: END (PASS) - Cookbook sre.hosts.downtime (exit_code=0) for 1 day, 0:00:00 on db2095.codfw.wmnet with reason: Maintenance
16:09 ladsgroup@cumin1001: START - Cookbook sre.hosts.downtime for 1 day, 0:00:00 on db2095.codfw.wmnet with reason: Maintenance
16:07 ladsgroup@cumin1001: END (PASS) - Cookbook sre.hosts.downtime (exit_code=0) for 2 days, 0:00:00 on clouddb[1013,1017,1021].eqiad.wmnet with reason: Maintenance
16:07 ladsgroup@cumin1001: START - Cookbook sre.hosts.downtime for 2 days, 0:00:00 on clouddb[1013,1017,1021].eqiad.wmnet with reason: Maintenance
16:07 ladsgroup@cumin1001: END (PASS) - Cookbook sre.hosts.downtime (exit_code=0) for 1 day, 0:00:00 on db1154.eqiad.wmnet with reason: Maintenance
16:07 ladsgroup@cumin1001: START - Cookbook sre.hosts.downtime for 1 day, 0:00:00 on db1154.eqiad.wmnet with reason: Maintenance
16:05 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db1191 (T314041)', diff saved to https://phabricator.wikimedia.org/P34628 and previous config saved to /var/cache/conftool/dbconfig/20220913-160536-ladsgroup.json
15:50 marostegui@cumin1001: END (PASS) - Cookbook sre.hosts.downtime (exit_code=0) for 1 day, 0:00:00 on db1189.eqiad.wmnet with reason: down
15:50 marostegui@cumin1001: START - Cookbook sre.hosts.downtime for 1 day, 0:00:00 on db1189.eqiad.wmnet with reason: down
15:48 marostegui@cumin1001: dbctl commit (dc=all): 'Depool db1189', diff saved to https://phabricator.wikimedia.org/P34626 and previous config saved to /var/cache/conftool/dbconfig/20220913-154810-root.json
15:42 ebernhardson@deploy1002: Finished deploy [wikimedia/discovery/analytics@031604d]: Automatically drop hitsorical partitions of subgraph analysis (duration: 02m 07s)
15:42 ladsgroup@cumin1001: END (PASS) - Cookbook sre.hosts.downtime (exit_code=0) for 1 day, 0:00:00 on db1145.eqiad.wmnet with reason: Maintenance
15:41 ladsgroup@cumin1001: START - Cookbook sre.hosts.downtime for 1 day, 0:00:00 on db1145.eqiad.wmnet with reason: Maintenance
15:41 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db1112 (T314041)', diff saved to https://phabricator.wikimedia.org/P34625 and previous config saved to /var/cache/conftool/dbconfig/20220913-154151-ladsgroup.json
15:40 ebernhardson@deploy1002: Started deploy [wikimedia/discovery/analytics@031604d]: Automatically drop hitsorical partitions of subgraph analysis
15:26 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db1112', diff saved to https://phabricator.wikimedia.org/P34624 and previous config saved to /var/cache/conftool/dbconfig/20220913-152644-ladsgroup.json
15:13 volans@cumin1001: END (PASS) - Cookbook sre.deploy.python-code (exit_code=0) homer to cumin2002.codfw.wmnet,cumin1001.eqiad.wmnet with reason: Release v0.6.0 - volans@cumin1001
15:12 volans@cumin1001: START - Cookbook sre.deploy.python-code homer to cumin2002.codfw.wmnet,cumin1001.eqiad.wmnet with reason: Release v0.6.0 - volans@cumin1001
15:11 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db1112', diff saved to https://phabricator.wikimedia.org/P34623 and previous config saved to /var/cache/conftool/dbconfig/20220913-151138-ladsgroup.json
15:10 dancy@deploy1002: Started scap: testwikis wikis to 1.39.0-wmf.28 refs T314190
14:56 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db1112 (T314041)', diff saved to https://phabricator.wikimedia.org/P34622 and previous config saved to /var/cache/conftool/dbconfig/20220913-145631-ladsgroup.json
14:54 dancy@deploy1002: Started scap: testwikis wikis to 1.40.0-wmf.1 refs T314190
14:12 cmooney@cumin1001: END (PASS) - Cookbook sre.hosts.remove-downtime (exit_code=0) for cr2-codfw,cr2-codfw IPv6,re0.cr2-codfw.mgmt
14:12 cmooney@cumin1001: START - Cookbook sre.hosts.remove-downtime for cr2-codfw,cr2-codfw IPv6,re0.cr2-codfw.mgmt
14:07 topranks: re-activating Transit on IX BGP on cr2-codfw
13:57 ladsgroup@cumin1001: dbctl commit (dc=all): 'Depooling db2168:3317 (T314041)', diff saved to https://phabricator.wikimedia.org/P34621 and previous config saved to /var/cache/conftool/dbconfig/20220913-135729-ladsgroup.json
13:57 ladsgroup@cumin1001: END (PASS) - Cookbook sre.hosts.downtime (exit_code=0) for 1 day, 0:00:00 on db2168.codfw.wmnet with reason: Maintenance
13:57 ladsgroup@cumin1001: START - Cookbook sre.hosts.downtime for 1 day, 0:00:00 on db2168.codfw.wmnet with reason: Maintenance
13:57 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db2159 (T314041)', diff saved to https://phabricator.wikimedia.org/P34620 and previous config saved to /var/cache/conftool/dbconfig/20220913-135707-ladsgroup.json
13:42 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db2159', diff saved to https://phabricator.wikimedia.org/P34619 and previous config saved to /var/cache/conftool/dbconfig/20220913-134201-ladsgroup.json
13:33 ladsgroup@cumin1001: dbctl commit (dc=all): 'Depooling db1191 (T314041)', diff saved to https://phabricator.wikimedia.org/P34618 and previous config saved to /var/cache/conftool/dbconfig/20220913-133339-ladsgroup.json
13:33 ladsgroup@cumin1001: END (PASS) - Cookbook sre.hosts.downtime (exit_code=0) for 1 day, 0:00:00 on db1191.eqiad.wmnet with reason: Maintenance
13:33 ladsgroup@cumin1001: START - Cookbook sre.hosts.downtime for 1 day, 0:00:00 on db1191.eqiad.wmnet with reason: Maintenance
13:33 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db1174 (T314041)', diff saved to https://phabricator.wikimedia.org/P34617 and previous config saved to /var/cache/conftool/dbconfig/20220913-133317-ladsgroup.json
13:33 Lucas_WMDE: UTC afternoon backport+config window done
13:26 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db2159', diff saved to https://phabricator.wikimedia.org/P34616 and previous config saved to /var/cache/conftool/dbconfig/20220913-132654-ladsgroup.json
13:19 Emperor: set thanos ring replicas to 3.85 T311690
13:18 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db1174', diff saved to https://phabricator.wikimedia.org/P34615 and previous config saved to /var/cache/conftool/dbconfig/20220913-131811-ladsgroup.json
13:14 topranks: Flipping back to RE0 on cr2-codfw (last disruptive switch)
13:11 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db2159 (T314041)', diff saved to https://phabricator.wikimedia.org/P34614 and previous config saved to /var/cache/conftool/dbconfig/20220913-131148-ladsgroup.json
13:08 ladsgroup@cumin1001: END (PASS) - Cookbook sre.hosts.downtime (exit_code=0) for 2 days, 0:00:00 on clouddb[1014,1018,1021].eqiad.wmnet with reason: Maintenance
13:08 ladsgroup@cumin1001: START - Cookbook sre.hosts.downtime for 2 days, 0:00:00 on clouddb[1014,1018,1021].eqiad.wmnet with reason: Maintenance
13:08 ladsgroup@cumin1001: END (PASS) - Cookbook sre.hosts.downtime (exit_code=0) for 1 day, 0:00:00 on db1155.eqiad.wmnet with reason: Maintenance
13:08 ladsgroup@cumin1001: START - Cookbook sre.hosts.downtime for 1 day, 0:00:00 on db1155.eqiad.wmnet with reason: Maintenance
13:07 ladsgroup@cumin1001: END (PASS) - Cookbook sre.hosts.downtime (exit_code=0) for 2 days, 0:00:00 on clouddb[1014,1018,1021].eqiad.wmnet with reason: Maintenance
13:07 ladsgroup@cumin1001: START - Cookbook sre.hosts.downtime for 2 days, 0:00:00 on clouddb[1014,1018,1021].eqiad.wmnet with reason: Maintenance
13:07 ladsgroup@cumin1001: END (PASS) - Cookbook sre.hosts.downtime (exit_code=0) for 1 day, 0:00:00 on db1155.eqiad.wmnet with reason: Maintenance
13:07 ladsgroup@cumin1001: START - Cookbook sre.hosts.downtime for 1 day, 0:00:00 on db1155.eqiad.wmnet with reason: Maintenance
13:03 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db1174', diff saved to https://phabricator.wikimedia.org/P34613 and previous config saved to /var/cache/conftool/dbconfig/20220913-130304-ladsgroup.json
12:59 topranks: Switching active RE back to RE1 on cr1-codfw as firmware hadn't been loaded while it was master
12:57 ladsgroup@cumin1001: dbctl commit (dc=all): 'Depooling db1148 (T314041)', diff saved to https://phabricator.wikimedia.org/P34612 and previous config saved to /var/cache/conftool/dbconfig/20220913-125745-ladsgroup.json
12:57 ladsgroup@cumin1001: END (PASS) - Cookbook sre.hosts.downtime (exit_code=0) for 1 day, 0:00:00 on db1148.eqiad.wmnet with reason: Maintenance
12:57 ladsgroup@cumin1001: START - Cookbook sre.hosts.downtime for 1 day, 0:00:00 on db1148.eqiad.wmnet with reason: Maintenance
12:57 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db1147 (T314041)', diff saved to https://phabricator.wikimedia.org/P34611 and previous config saved to /var/cache/conftool/dbconfig/20220913-125723-ladsgroup.json
12:47 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db1174 (T314041)', diff saved to https://phabricator.wikimedia.org/P34610 and previous config saved to /var/cache/conftool/dbconfig/20220913-124758-ladsgroup.json
12:46 topranks: forcing non-graceful RE switchover on cr2-codfw as part of upgrade
12:42 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db1147', diff saved to https://phabricator.wikimedia.org/P34609 and previous config saved to /var/cache/conftool/dbconfig/20220913-124217-ladsgroup.json
12:27 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db1147', diff saved to https://phabricator.wikimedia.org/P34608 and previous config saved to /var/cache/conftool/dbconfig/20220913-122710-ladsgroup.json
12:24 marostegui@cumin1001: dbctl commit (dc=all): 'db2104 (re)pooling @ 100%: Repooling after upgrade', diff saved to https://phabricator.wikimedia.org/P34607 and previous config saved to /var/cache/conftool/dbconfig/20220913-122415-root.json
12:12 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db1147 (T314041)', diff saved to https://phabricator.wikimedia.org/P34606 and previous config saved to /var/cache/conftool/dbconfig/20220913-121204-ladsgroup.json
12:09 marostegui@cumin1001: dbctl commit (dc=all): 'db2104 (re)pooling @ 75%: Repooling after upgrade', diff saved to https://phabricator.wikimedia.org/P34605 and previous config saved to /var/cache/conftool/dbconfig/20220913-120910-root.json
12:06 ladsgroup@cumin1001: dbctl commit (dc=all): 'Depooling db2127 (T314041)', diff saved to https://phabricator.wikimedia.org/P34604 and previous config saved to /var/cache/conftool/dbconfig/20220913-120653-ladsgroup.json
12:06 ladsgroup@cumin1001: END (PASS) - Cookbook sre.hosts.downtime (exit_code=0) for 1 day, 0:00:00 on db2127.codfw.wmnet with reason: Maintenance
12:06 ladsgroup@cumin1001: START - Cookbook sre.hosts.downtime for 1 day, 0:00:00 on db2127.codfw.wmnet with reason: Maintenance
12:06 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db2109 (T314041)', diff saved to https://phabricator.wikimedia.org/P34603 and previous config saved to /var/cache/conftool/dbconfig/20220913-120632-ladsgroup.json
11:58 topranks: Disabling transit and ixp BGP on cr2-codfw in advance of software upgrade
11:54 marostegui@cumin1001: dbctl commit (dc=all): 'db2104 (re)pooling @ 50%: Repooling after upgrade', diff saved to https://phabricator.wikimedia.org/P34602 and previous config saved to /var/cache/conftool/dbconfig/20220913-115405-root.json
11:51 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db2109', diff saved to https://phabricator.wikimedia.org/P34601 and previous config saved to /var/cache/conftool/dbconfig/20220913-115125-ladsgroup.json
11:39 marostegui@cumin1001: dbctl commit (dc=all): 'db2104 (re)pooling @ 25%: Repooling after upgrade', diff saved to https://phabricator.wikimedia.org/P34600 and previous config saved to /var/cache/conftool/dbconfig/20220913-113900-root.json
11:36 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db2109', diff saved to https://phabricator.wikimedia.org/P34599 and previous config saved to /var/cache/conftool/dbconfig/20220913-113619-ladsgroup.json
11:28 ladsgroup@cumin1001: dbctl commit (dc=all): 'Depooling db1112 (T314041)', diff saved to https://phabricator.wikimedia.org/P34598 and previous config saved to /var/cache/conftool/dbconfig/20220913-112818-ladsgroup.json
11:28 ladsgroup@cumin1001: END (PASS) - Cookbook sre.hosts.downtime (exit_code=0) for 2 days, 0:00:00 on clouddb[1013,1017,1021].eqiad.wmnet,db1154.eqiad.wmnet with reason: Maintenance
11:27 ladsgroup@cumin1001: START - Cookbook sre.hosts.downtime for 2 days, 0:00:00 on clouddb[1013,1017,1021].eqiad.wmnet,db1154.eqiad.wmnet with reason: Maintenance
11:27 ladsgroup@cumin1001: END (PASS) - Cookbook sre.hosts.downtime (exit_code=0) for 1 day, 0:00:00 on db1112.eqiad.wmnet with reason: Maintenance
11:27 ladsgroup@cumin1001: START - Cookbook sre.hosts.downtime for 1 day, 0:00:00 on db1112.eqiad.wmnet with reason: Maintenance
11:23 marostegui@cumin1001: dbctl commit (dc=all): 'db2104 (re)pooling @ 10%: Repooling after upgrade', diff saved to https://phabricator.wikimedia.org/P34597 and previous config saved to /var/cache/conftool/dbconfig/20220913-112355-root.json
11:21 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db2109 (T314041)', diff saved to https://phabricator.wikimedia.org/P34596 and previous config saved to /var/cache/conftool/dbconfig/20220913-112112-ladsgroup.json
11:21 cmooney@cumin1001: END (PASS) - Cookbook sre.hosts.downtime (exit_code=0) for 3:00:00 on cr2-codfw,cr2-codfw IPv6,re0.cr2-codfw.mgmt with reason: router upgrade
11:20 cmooney@cumin1001: START - Cookbook sre.hosts.downtime for 3:00:00 on cr2-codfw,cr2-codfw IPv6,re0.cr2-codfw.mgmt with reason: router upgrade
11:15 topranks: completed cr1-codfw upgrade, will proceed to cr2-codfw shortly
11:14 cmooney@cumin1001: END (PASS) - Cookbook sre.hosts.remove-downtime (exit_code=0) for cr1-codfw,cr1-codfw IPv6,re0.cr1-codfw.mgmt
11:14 cmooney@cumin1001: START - Cookbook sre.hosts.remove-downtime for cr1-codfw,cr1-codfw IPv6,re0.cr1-codfw.mgmt
11:07 marostegui@cumin1001: dbctl commit (dc=all): 'db2103 (re)pooling @ 100%: Repooling after upgrade', diff saved to https://phabricator.wikimedia.org/P34593 and previous config saved to /var/cache/conftool/dbconfig/20220913-110715-root.json
11:03 btullis@cumin1001: END (PASS) - Cookbook sre.hadoop.roll-restart-masters (exit_code=0) restart masters for Hadoop analytics cluster: Restart of jvm daemons.
10:57 marostegui@cumin1001: dbctl commit (dc=all): 'Depool db2104 T317627', diff saved to https://phabricator.wikimedia.org/P34592 and previous config saved to /var/cache/conftool/dbconfig/20220913-105733-root.json
10:56 marostegui@cumin1001: dbctl commit (dc=all): 'Promote db2107 to s2 codfw primary T317627', diff saved to https://phabricator.wikimedia.org/P34591 and previous config saved to /var/cache/conftool/dbconfig/20220913-105642-marostegui.json
10:56 elukey@cumin1001: END (PASS) - Cookbook sre.ores.roll-restart-workers (exit_code=0) for ORES eqiad cluster: Roll restart of ORES's daemons.
10:56 marostegui: Starting s2 codfw failover from db2104 to db2107 - T317627
10:52 marostegui@cumin1001: dbctl commit (dc=all): 'db2103 (re)pooling @ 75%: Repooling after upgrade', diff saved to https://phabricator.wikimedia.org/P34590 and previous config saved to /var/cache/conftool/dbconfig/20220913-105210-root.json
10:37 marostegui@cumin1001: dbctl commit (dc=all): 'db2103 (re)pooling @ 50%: Repooling after upgrade', diff saved to https://phabricator.wikimedia.org/P34589 and previous config saved to /var/cache/conftool/dbconfig/20220913-103705-root.json
10:37 marostegui@cumin1001: dbctl commit (dc=all): 'Depool db2107 from api T317627', diff saved to https://phabricator.wikimedia.org/P34588 and previous config saved to /var/cache/conftool/dbconfig/20220913-103658-marostegui.json
10:36 marostegui@cumin1001: dbctl commit (dc=all): 'Set db2107 with weight 0 T317627', diff saved to https://phabricator.wikimedia.org/P34587 and previous config saved to /var/cache/conftool/dbconfig/20220913-103621-marostegui.json
10:35 elukey@cumin1001: START - Cookbook sre.ores.roll-restart-workers for ORES eqiad cluster: Roll restart of ORES's daemons.
10:35 marostegui@cumin1001: END (PASS) - Cookbook sre.hosts.downtime (exit_code=0) for 1:00:00 on 27 hosts with reason: Primary switchover s2 T317627
10:35 marostegui@cumin1001: START - Cookbook sre.hosts.downtime for 1:00:00 on 27 hosts with reason: Primary switchover s2 T317627
10:22 ladsgroup@cumin1001: dbctl commit (dc=all): 'Depooling db1174 (T314041)', diff saved to https://phabricator.wikimedia.org/P34586 and previous config saved to /var/cache/conftool/dbconfig/20220913-102232-ladsgroup.json
10:22 ladsgroup@cumin1001: END (PASS) - Cookbook sre.hosts.downtime (exit_code=0) for 1 day, 0:00:00 on db1174.eqiad.wmnet with reason: Maintenance
10:22 ladsgroup@cumin1001: START - Cookbook sre.hosts.downtime for 1 day, 0:00:00 on db1174.eqiad.wmnet with reason: Maintenance
10:21 marostegui@cumin1001: dbctl commit (dc=all): 'db2103 (re)pooling @ 25%: Repooling after upgrade', diff saved to https://phabricator.wikimedia.org/P34585 and previous config saved to /var/cache/conftool/dbconfig/20220913-102147-root.json
10:16 topranks: Flipping master RE on cr1-codfw to backup as part of upgrade
10:06 marostegui@cumin1001: dbctl commit (dc=all): 'db2103 (re)pooling @ 10%: Repooling after upgrade', diff saved to https://phabricator.wikimedia.org/P34584 and previous config saved to /var/cache/conftool/dbconfig/20220913-100642-root.json
10:04 elukey@cumin1001: END (PASS) - Cookbook sre.ores.roll-restart-workers (exit_code=0) for ORES codfw cluster: Roll restart of ORES's daemons.
09:52 elukey: restart kafka on kafka-logging2002 to move it to PKI-based TLS certs
09:51 marostegui@cumin1001: dbctl commit (dc=all): 'db2103 (re)pooling @ 5%: Repooling after upgrade', diff saved to https://phabricator.wikimedia.org/P34583 and previous config saved to /var/cache/conftool/dbconfig/20220913-095137-root.json
09:51 elukey@cumin1001: END (PASS) - Cookbook sre.hosts.downtime (exit_code=0) for 0:20:00 on kafka-logging2002.codfw.wmnet with reason: Kafka PKI upgrade
09:50 elukey@cumin1001: START - Cookbook sre.hosts.downtime for 0:20:00 on kafka-logging2002.codfw.wmnet with reason: Kafka PKI upgrade
09:45 elukey@cumin1001: START - Cookbook sre.ores.roll-restart-workers for ORES codfw cluster: Roll restart of ORES's daemons.
09:42 btullis@cumin1001: END (PASS) - Cookbook sre.hosts.reboot-single (exit_code=0) for host an-worker1101.eqiad.wmnet
09:41 btullis@cumin1001: START - Cookbook sre.hadoop.roll-restart-masters restart masters for Hadoop analytics cluster: Restart of jvm daemons.
09:37 hashar: Restarting CI Jenkins on contint2001 (with new systemd service)
09:33 hashar: Enabling Puppet on contint2001 for Jenkins systemd change
09:33 btullis@cumin1001: START - Cookbook sre.hosts.reboot-single for host an-worker1101.eqiad.wmnet
09:29 ladsgroup@cumin1001: dbctl commit (dc=all): 'Depooling db2159 (T314041)', diff saved to https://phabricator.wikimedia.org/P34582 and previous config saved to /var/cache/conftool/dbconfig/20220913-092904-ladsgroup.json
09:28 ladsgroup@cumin1001: END (PASS) - Cookbook sre.hosts.downtime (exit_code=0) for 2 days, 0:00:00 on db2095.codfw.wmnet with reason: Maintenance
09:28 ladsgroup@cumin1001: START - Cookbook sre.hosts.downtime for 2 days, 0:00:00 on db2095.codfw.wmnet with reason: Maintenance
09:28 ladsgroup@cumin1001: END (PASS) - Cookbook sre.hosts.downtime (exit_code=0) for 1 day, 0:00:00 on db2159.codfw.wmnet with reason: Maintenance
09:28 ladsgroup@cumin1001: START - Cookbook sre.hosts.downtime for 1 day, 0:00:00 on db2159.codfw.wmnet with reason: Maintenance
09:28 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db2150 (T314041)', diff saved to https://phabricator.wikimedia.org/P34581 and previous config saved to /var/cache/conftool/dbconfig/20220913-092826-ladsgroup.json
09:25 hashar: Stopped Puppet on contint2001 for a Jenkins systemd change
09:22 marostegui@cumin1001: dbctl commit (dc=all): 'Depool db2103 T317614', diff saved to https://phabricator.wikimedia.org/P34580 and previous config saved to /var/cache/conftool/dbconfig/20220913-092200-root.json
09:20 marostegui@cumin1001: dbctl commit (dc=all): 'Promote db2112 to s1 primary T317614', diff saved to https://phabricator.wikimedia.org/P34579 and previous config saved to /var/cache/conftool/dbconfig/20220913-092032-root.json
09:19 marostegui: Starting s1 codfw failover from db2103 to db2112 - T317614
09:13 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db2150', diff saved to https://phabricator.wikimedia.org/P34578 and previous config saved to /var/cache/conftool/dbconfig/20220913-091320-ladsgroup.json
09:11 volans@cumin1001: END (PASS) - Cookbook sre.network.cf (exit_code=0)
09:02 cmooney@cumin1001: END (PASS) - Cookbook sre.hosts.downtime (exit_code=0) for 2:00:00 on cr1-codfw,cr1-codfw IPv6,re0.cr1-codfw.mgmt with reason: router upgrade
09:02 cmooney@cumin1001: START - Cookbook sre.hosts.downtime for 2:00:00 on cr1-codfw,cr1-codfw IPv6,re0.cr1-codfw.mgmt with reason: router upgrade
08:58 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db2150', diff saved to https://phabricator.wikimedia.org/P34577 and previous config saved to /var/cache/conftool/dbconfig/20220913-085814-ladsgroup.json
08:56 topranks: Flipping primary routing engine to RE1 on cr1-codfw (disruptive) as part of upgrade.
08:54 marostegui@cumin1001: dbctl commit (dc=all): 'Set db2112 with weight 0 T317614', diff saved to https://phabricator.wikimedia.org/P34576 and previous config saved to /var/cache/conftool/dbconfig/20220913-085456-marostegui.json
08:54 marostegui@cumin1001: END (PASS) - Cookbook sre.hosts.downtime (exit_code=0) for 1:00:00 on 37 hosts with reason: Primary switchover s1 T317614
08:54 marostegui@cumin1001: START - Cookbook sre.hosts.downtime for 1:00:00 on 37 hosts with reason: Primary switchover s1 T317614
08:46 topranks: Disabled LVS/PyBal peerings on cr1-codfw ain advance of upgrade to router.
08:46 btullis@cumin1001: END (PASS) - Cookbook sre.hosts.reboot-single (exit_code=0) for host an-worker1100.eqiad.wmnet
08:43 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db2150 (T314041)', diff saved to https://phabricator.wikimedia.org/P34575 and previous config saved to /var/cache/conftool/dbconfig/20220913-084307-ladsgroup.json
08:39 btullis@cumin1001: START - Cookbook sre.hosts.reboot-single for host an-worker1100.eqiad.wmnet
08:36 btullis@cumin1001: END (PASS) - Cookbook sre.hosts.reboot-single (exit_code=0) for host an-worker1099.eqiad.wmnet
08:27 btullis@cumin1001: START - Cookbook sre.hosts.reboot-single for host an-worker1099.eqiad.wmnet
08:27 cmooney@cumin1001: END (PASS) - Cookbook sre.network.cf (exit_code=0)
06:55 ladsgroup@cumin1001: END (PASS) - Cookbook sre.hosts.downtime (exit_code=0) for 1 day, 0:00:00 on db1171.eqiad.wmnet with reason: Maintenance
06:55 ladsgroup@cumin1001: START - Cookbook sre.hosts.downtime for 1 day, 0:00:00 on db1171.eqiad.wmnet with reason: Maintenance
06:54 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db1170:3317 (T314041)', diff saved to https://phabricator.wikimedia.org/P34574 and previous config saved to /var/cache/conftool/dbconfig/20220913-065457-ladsgroup.json
06:39 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db1170:3317', diff saved to https://phabricator.wikimedia.org/P34573 and previous config saved to /var/cache/conftool/dbconfig/20220913-063951-ladsgroup.json
06:39 ladsgroup@cumin1001: dbctl commit (dc=all): 'Depooling db2109 (T314041)', diff saved to https://phabricator.wikimedia.org/P34572 and previous config saved to /var/cache/conftool/dbconfig/20220913-063908-ladsgroup.json
06:39 ladsgroup@cumin1001: END (PASS) - Cookbook sre.hosts.downtime (exit_code=0) for 1 day, 0:00:00 on db2109.codfw.wmnet with reason: Maintenance
06:38 ladsgroup@cumin1001: START - Cookbook sre.hosts.downtime for 1 day, 0:00:00 on db2109.codfw.wmnet with reason: Maintenance
06:38 ladsgroup@cumin1001: END (PASS) - Cookbook sre.hosts.downtime (exit_code=0) for 1 day, 0:00:00 on db1102.eqiad.wmnet with reason: Maintenance
06:38 ladsgroup@cumin1001: START - Cookbook sre.hosts.downtime for 1 day, 0:00:00 on db1102.eqiad.wmnet with reason: Maintenance
06:24 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db1170:3317', diff saved to https://phabricator.wikimedia.org/P34571 and previous config saved to /var/cache/conftool/dbconfig/20220913-062444-ladsgroup.json
06:09 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db1170:3317 (T314041)', diff saved to https://phabricator.wikimedia.org/P34570 and previous config saved to /var/cache/conftool/dbconfig/20220913-060938-ladsgroup.json
04:58 ladsgroup@cumin1001: dbctl commit (dc=all): 'Depooling db2150 (T314041)', diff saved to https://phabricator.wikimedia.org/P34569 and previous config saved to /var/cache/conftool/dbconfig/20220913-045832-ladsgroup.json
04:58 ladsgroup@cumin1001: END (PASS) - Cookbook sre.hosts.downtime (exit_code=0) for 1 day, 0:00:00 on db2150.codfw.wmnet with reason: Maintenance
04:58 ladsgroup@cumin1001: START - Cookbook sre.hosts.downtime for 1 day, 0:00:00 on db2150.codfw.wmnet with reason: Maintenance
04:58 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db2122 (T314041)', diff saved to https://phabricator.wikimedia.org/P34568 and previous config saved to /var/cache/conftool/dbconfig/20220913-045811-ladsgroup.json
04:43 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db2122', diff saved to https://phabricator.wikimedia.org/P34567 and previous config saved to /var/cache/conftool/dbconfig/20220913-044304-ladsgroup.json
04:27 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db2122', diff saved to https://phabricator.wikimedia.org/P34566 and previous config saved to /var/cache/conftool/dbconfig/20220913-042758-ladsgroup.json
04:12 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db2122 (T314041)', diff saved to https://phabricator.wikimedia.org/P34565 and previous config saved to /var/cache/conftool/dbconfig/20220913-041251-ladsgroup.json
02:21 ladsgroup@cumin1001: dbctl commit (dc=all): 'Depooling db1170:3317 (T314041)', diff saved to https://phabricator.wikimedia.org/P34564 and previous config saved to /var/cache/conftool/dbconfig/20220913-022136-ladsgroup.json
02:21 ladsgroup@cumin1001: END (PASS) - Cookbook sre.hosts.downtime (exit_code=0) for 1 day, 0:00:00 on db1170.eqiad.wmnet with reason: Maintenance
02:21 ladsgroup@cumin1001: START - Cookbook sre.hosts.downtime for 1 day, 0:00:00 on db1170.eqiad.wmnet with reason: Maintenance
02:21 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db1158 (T314041)', diff saved to https://phabricator.wikimedia.org/P34563 and previous config saved to /var/cache/conftool/dbconfig/20220913-022114-ladsgroup.json
02:06 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db1158', diff saved to https://phabricator.wikimedia.org/P34562 and previous config saved to /var/cache/conftool/dbconfig/20220913-020608-ladsgroup.json
01:51 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db1158', diff saved to https://phabricator.wikimedia.org/P34561 and previous config saved to /var/cache/conftool/dbconfig/20220913-015102-ladsgroup.json
01:35 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db1158 (T314041)', diff saved to https://phabricator.wikimedia.org/P34560 and previous config saved to /var/cache/conftool/dbconfig/20220913-013555-ladsgroup.json
00:49 dzahn@cumin2002: END (PASS) - Cookbook sre.hosts.downtime (exit_code=0) for 1:00:00 on phab2001.codfw.wmnet with reason: syntax error in sudo
00:49 dzahn@cumin2002: START - Cookbook sre.hosts.downtime for 1:00:00 on phab2001.codfw.wmnet with reason: syntax error in sudo
00:49 dzahn@cumin2002: END (PASS) - Cookbook sre.hosts.downtime (exit_code=0) for 1:00:00 on phab2002.codfw.wmnet with reason: syntax error in sudo
00:49 dzahn@cumin2002: START - Cookbook sre.hosts.downtime for 1:00:00 on phab2002.codfw.wmnet with reason: syntax error in sudo
00:48 dzahn@cumin2002: END (PASS) - Cookbook sre.hosts.downtime (exit_code=0) for 1:00:00 on phab1004.eqiad.wmnet with reason: syntax error in sudo
00:48 dzahn@cumin2002: START - Cookbook sre.hosts.downtime for 1:00:00 on phab1004.eqiad.wmnet with reason: syntax error in sudo
00:19 ladsgroup@cumin1001: dbctl commit (dc=all): 'Depooling db2122 (T314041)', diff saved to https://phabricator.wikimedia.org/P34559 and previous config saved to /var/cache/conftool/dbconfig/20220913-001908-ladsgroup.json
00:19 ladsgroup@cumin1001: END (PASS) - Cookbook sre.hosts.downtime (exit_code=0) for 1 day, 0:00:00 on db2122.codfw.wmnet with reason: Maintenance
00:18 ladsgroup@cumin1001: START - Cookbook sre.hosts.downtime for 1 day, 0:00:00 on db2122.codfw.wmnet with reason: Maintenance
00:18 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db2120 (T314041)', diff saved to https://phabricator.wikimedia.org/P34558 and previous config saved to /var/cache/conftool/dbconfig/20220913-001846-ladsgroup.json
00:03 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db2120', diff saved to https://phabricator.wikimedia.org/P34557 and previous config saved to /var/cache/conftool/dbconfig/20220913-000340-ladsgroup.json
2022-09-12
23:48 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db2120', diff saved to https://phabricator.wikimedia.org/P34556 and previous config saved to /var/cache/conftool/dbconfig/20220912-234833-ladsgroup.json
23:33 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db2120 (T314041)', diff saved to https://phabricator.wikimedia.org/P34555 and previous config saved to /var/cache/conftool/dbconfig/20220912-233327-ladsgroup.json
22:53 mutante: phabricator - disabling MediaWiki extension repositories in Diffusion that have 0 commits - T296022 - T315706
22:40 ladsgroup@cumin1001: dbctl commit (dc=all): 'Depooling db1158 (T314041)', diff saved to https://phabricator.wikimedia.org/P34554 and previous config saved to /var/cache/conftool/dbconfig/20220912-224006-ladsgroup.json
22:40 ladsgroup@cumin1001: END (PASS) - Cookbook sre.hosts.downtime (exit_code=0) for 2 days, 0:00:00 on clouddb[1014,1018,1021].eqiad.wmnet,db1155.eqiad.wmnet with reason: Maintenance
22:39 ladsgroup@cumin1001: START - Cookbook sre.hosts.downtime for 2 days, 0:00:00 on clouddb[1014,1018,1021].eqiad.wmnet,db1155.eqiad.wmnet with reason: Maintenance
22:39 ladsgroup@cumin1001: END (PASS) - Cookbook sre.hosts.downtime (exit_code=0) for 1 day, 0:00:00 on db1158.eqiad.wmnet with reason: Maintenance
22:39 ladsgroup@cumin1001: START - Cookbook sre.hosts.downtime for 1 day, 0:00:00 on db1158.eqiad.wmnet with reason: Maintenance
22:39 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db1136 (T314041)', diff saved to https://phabricator.wikimedia.org/P34553 and previous config saved to /var/cache/conftool/dbconfig/20220912-223927-ladsgroup.json
22:24 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db1136', diff saved to https://phabricator.wikimedia.org/P34552 and previous config saved to /var/cache/conftool/dbconfig/20220912-222420-ladsgroup.json
22:23 mutante: phabricator - disabling repositories: tool-xh-bot, tool-editor-contribution-dashboard, tool-ranker, tool-editor-contribution, tool-mikasa-bot-1, tool-maintun, tool-add-text, tool-wikibookassamese-book.php (none of them had commits) T296022 - T315706
22:09 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db1136', diff saved to https://phabricator.wikimedia.org/P34551 and previous config saved to /var/cache/conftool/dbconfig/20220912-220914-ladsgroup.json
21:54 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db1136 (T314041)', diff saved to https://phabricator.wikimedia.org/P34550 and previous config saved to /var/cache/conftool/dbconfig/20220912-215407-ladsgroup.json
21:07 bmansurov@deploy1002: Started deploy [airflow-dags/research@b9be20d]: (no justification provided)
21:01 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db2176 (T312863)', diff saved to https://phabricator.wikimedia.org/P34549 and previous config saved to /var/cache/conftool/dbconfig/20220912-210123-ladsgroup.json
20:57 TheresNoTime: closing UTC late backport window
20:51 samtar@deploy1002: samtar and ebernhardson: Backport for Set track_total_hits to true synced to the testservers: mwdebug1002.eqiad.wmnet, mwdebug2002.codfw.wmnet, mwdebug1001.eqiad.wmnet, mwdebug2001.codfw.wmnet
20:46 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db2176', diff saved to https://phabricator.wikimedia.org/P34548 and previous config saved to /var/cache/conftool/dbconfig/20220912-204617-ladsgroup.json
20:42 samtar@deploy1002: samtar and jdlrobson: Backport for Enable Nearby on Hebrew and French Wikipedia (T246493) synced to the testservers: mwdebug1002.eqiad.wmnet, mwdebug2002.codfw.wmnet, mwdebug1001.eqiad.wmnet, mwdebug2001.codfw.wmnet
20:38 herron@cumin1001: END (PASS) - Cookbook sre.ganeti.makevm (exit_code=0) for new host dispatch-be1001.eqiad.wmnet
20:34 samtar@deploy1002: samtar and dani: Backport for Deploy Research Incentive Survey to idwiki (T316466) synced to the testservers: mwdebug1002.eqiad.wmnet, mwdebug1001.eqiad.wmnet, mwdebug2002.codfw.wmnet, mwdebug2001.codfw.wmnet
20:31 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db2176', diff saved to https://phabricator.wikimedia.org/P34547 and previous config saved to /var/cache/conftool/dbconfig/20220912-203110-ladsgroup.json
20:26 samtar@deploy1002: samtar and ebernhardson: Backport for Re-enable track_total_hits for elastic7 (T317374) synced to the testservers: mwdebug1001.eqiad.wmnet, mwdebug2001.codfw.wmnet, mwdebug2002.codfw.wmnet, mwdebug1002.eqiad.wmnet
20:16 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db2176 (T312863)', diff saved to https://phabricator.wikimedia.org/P34545 and previous config saved to /var/cache/conftool/dbconfig/20220912-201604-ladsgroup.json
20:15 herron@cumin1001: END (PASS) - Cookbook sre.dns.wipe-cache (exit_code=0) dispatch-be1001.eqiad.wmnet on all recursors
20:14 herron@cumin1001: START - Cookbook sre.dns.wipe-cache dispatch-be1001.eqiad.wmnet on all recursors
20:14 herron@cumin1001: END (PASS) - Cookbook sre.dns.netbox (exit_code=0)
20:09 samtar@deploy1002: samtar and zabe: Backport for Mark spcomwiki and searchcomwiki as closed (T285685) synced to the testservers: mwdebug1002.eqiad.wmnet, mwdebug2002.codfw.wmnet, mwdebug2001.codfw.wmnet, mwdebug1001.eqiad.wmnet
19:59 pt1979@cumin2002: START - Cookbook sre.hosts.decommission for hosts theemin.codfw.wmnet
19:58 mstyles@deploy1002: Synchronized php-1.39.0-wmf.28/extensions/PageTriage/includes/Api/ApiPageTriageAction.php: (no justification provided) (duration: 03m 42s)
19:55 ladsgroup@cumin1001: dbctl commit (dc=all): 'Depooling db2120 (T314041)', diff saved to https://phabricator.wikimedia.org/P34544 and previous config saved to /var/cache/conftool/dbconfig/20220912-195540-ladsgroup.json
19:55 ladsgroup@cumin1001: END (PASS) - Cookbook sre.hosts.downtime (exit_code=0) for 1 day, 0:00:00 on db2120.codfw.wmnet with reason: Maintenance
19:55 ladsgroup@cumin1001: START - Cookbook sre.hosts.downtime for 1 day, 0:00:00 on db2120.codfw.wmnet with reason: Maintenance
19:55 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db2118 (T314041)', diff saved to https://phabricator.wikimedia.org/P34543 and previous config saved to /var/cache/conftool/dbconfig/20220912-195519-ladsgroup.json
19:53 sbassett: Deployed security patch for T311337
19:40 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db2118', diff saved to https://phabricator.wikimedia.org/P34542 and previous config saved to /var/cache/conftool/dbconfig/20220912-194013-ladsgroup.json
19:28 ladsgroup@cumin1001: dbctl commit (dc=all): 'Depooling db1136 (T314041)', diff saved to https://phabricator.wikimedia.org/P34541 and previous config saved to /var/cache/conftool/dbconfig/20220912-192858-ladsgroup.json
19:28 ladsgroup@cumin1001: END (PASS) - Cookbook sre.hosts.downtime (exit_code=0) for 1 day, 0:00:00 on db1136.eqiad.wmnet with reason: Maintenance
19:28 ladsgroup@cumin1001: START - Cookbook sre.hosts.downtime for 1 day, 0:00:00 on db1136.eqiad.wmnet with reason: Maintenance
19:28 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db1127 (T314041)', diff saved to https://phabricator.wikimedia.org/P34540 and previous config saved to /var/cache/conftool/dbconfig/20220912-192837-ladsgroup.json
19:26 bking@deploy1002: Started deploy [wdqs/wdqs@e012d14]: 0.3.116
19:25 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db2118', diff saved to https://phabricator.wikimedia.org/P34539 and previous config saved to /var/cache/conftool/dbconfig/20220912-192506-ladsgroup.json
19:20 dancy@deploy1002: Installation of scap version "4.19.0" completed for 561 hosts
19:20 dancy@deploy1002: Installing scap version "4.19.0" for 561 hosts
19:13 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db1127', diff saved to https://phabricator.wikimedia.org/P34538 and previous config saved to /var/cache/conftool/dbconfig/20220912-191330-ladsgroup.json
19:12 dancy@deploy1002: Installation of scap version "4.18.0" completed for 561 hosts
19:12 dancy@deploy1002: Installing scap version "4.18.0" for 561 hosts
19:10 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db2118 (T314041)', diff saved to https://phabricator.wikimedia.org/P34537 and previous config saved to /var/cache/conftool/dbconfig/20220912-191000-ladsgroup.json
19:08 inflatador: [WDQS Deploy] Deploy complete. Successful test query placed on query.wikidata.org, there's no relevant criticals in Icinga, and Grafana looks good
19:00 inflatador: [WCQS Deploy] Test query passed on commons-query.wikimedia.org; WCQS deploy complete
18:58 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db1127', diff saved to https://phabricator.wikimedia.org/P34536 and previous config saved to /var/cache/conftool/dbconfig/20220912-185823-ladsgroup.json
18:48 bking@deploy1002: Started deploy [wdqs/wdqs@e012d14] (wcqs): Deploy 0.3.116 to WCQS
18:43 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db1127 (T314041)', diff saved to https://phabricator.wikimedia.org/P34535 and previous config saved to /var/cache/conftool/dbconfig/20220912-184317-ladsgroup.json
18:37 inflatador: [WDQS Deploy] Restarting `wdqs-categories` across lvs-managed hosts, one node at a time: `sudo -E cumin -b 1 'A:wdqs-all and not A:wdqs-test' 'depool && sleep 45 && systemctl restart wdqs-categories && sleep 45 && pool'`
18:37 inflatador: [WDQS Deploy] Restarted `wdqs-categories` across all test hosts simultaneously: `sudo -E cumin 'A:wdqs-test' 'systemctl restart wdqs-categories'`
18:37 inflatador: [WDQS Deploy] Restarted `wdqs-updater` across all hosts, 4 hosts at a time: `sudo -E cumin -b 4 'A:wdqs-all' 'systemctl restart wdqs-updater'`
18:02 bking@deploy1002: Started deploy [wdqs/wdqs@e012d14]: 0.3.116
18:01 inflatador: [WDQS Deploy] Tests passing following deploy of `wdqs1003` on canary `wdqs1003`; proceeding to rest of fleet
17:57 inflatador: [WDQS Deploy] Gearing up for deploy of wdqs `0.3.116`. Pre-deploy tests passing on canary `wdqs1003`
17:43 ladsgroup@cumin1001: dbctl commit (dc=all): 'Depooling db1127 (T314041)', diff saved to https://phabricator.wikimedia.org/P34532 and previous config saved to /var/cache/conftool/dbconfig/20220912-174301-ladsgroup.json
17:42 ladsgroup@cumin1001: END (PASS) - Cookbook sre.hosts.downtime (exit_code=0) for 1 day, 0:00:00 on db1127.eqiad.wmnet with reason: Maintenance
17:42 ladsgroup@cumin1001: START - Cookbook sre.hosts.downtime for 1 day, 0:00:00 on db1127.eqiad.wmnet with reason: Maintenance
17:42 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db1101:3317 (T314041)', diff saved to https://phabricator.wikimedia.org/P34531 and previous config saved to /var/cache/conftool/dbconfig/20220912-174239-ladsgroup.json
17:27 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db1101:3317', diff saved to https://phabricator.wikimedia.org/P34529 and previous config saved to /var/cache/conftool/dbconfig/20220912-172733-ladsgroup.json
17:21 bmansurov@deploy1002: Started deploy [airflow-dags/research@b9be20d]: (no justification provided)
17:12 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db1101:3317', diff saved to https://phabricator.wikimedia.org/P34528 and previous config saved to /var/cache/conftool/dbconfig/20220912-171227-ladsgroup.json
17:08 cwhite: rebuilt raid on logstash2027 T316996
16:57 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db1101:3317 (T314041)', diff saved to https://phabricator.wikimedia.org/P34527 and previous config saved to /var/cache/conftool/dbconfig/20220912-165720-ladsgroup.json
15:54 bmansurov@deploy1002: Started deploy [airflow-dags/research@b9be20d]: (no justification provided)
15:29 ladsgroup@cumin1001: dbctl commit (dc=all): 'Depooling db2118 (T314041)', diff saved to https://phabricator.wikimedia.org/P34524 and previous config saved to /var/cache/conftool/dbconfig/20220912-152920-ladsgroup.json
15:29 ladsgroup@cumin1001: END (PASS) - Cookbook sre.hosts.downtime (exit_code=0) for 1 day, 0:00:00 on db2118.codfw.wmnet with reason: Maintenance
15:29 ladsgroup@cumin1001: START - Cookbook sre.hosts.downtime for 1 day, 0:00:00 on db2118.codfw.wmnet with reason: Maintenance
15:29 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db2108 (T314041)', diff saved to https://phabricator.wikimedia.org/P34523 and previous config saved to /var/cache/conftool/dbconfig/20220912-152858-ladsgroup.json
15:18 dancy@deploy1002: Installation of scap version "4.18.0" completed for 561 hosts
15:17 dancy@deploy1002: Installing scap version "4.18.0" for 561 hosts
15:13 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db2108', diff saved to https://phabricator.wikimedia.org/P34522 and previous config saved to /var/cache/conftool/dbconfig/20220912-151352-ladsgroup.json
14:58 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db2108', diff saved to https://phabricator.wikimedia.org/P34521 and previous config saved to /var/cache/conftool/dbconfig/20220912-145845-ladsgroup.json
14:43 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db2108 (T314041)', diff saved to https://phabricator.wikimedia.org/P34520 and previous config saved to /var/cache/conftool/dbconfig/20220912-144339-ladsgroup.json
14:14 ladsgroup@cumin1001: dbctl commit (dc=all): 'Depooling db2176 (T312863)', diff saved to https://phabricator.wikimedia.org/P34519 and previous config saved to /var/cache/conftool/dbconfig/20220912-141427-ladsgroup.json
14:14 ladsgroup@cumin1001: END (PASS) - Cookbook sre.hosts.downtime (exit_code=0) for 1 day, 0:00:00 on db2176.codfw.wmnet with reason: Maintenance
14:14 ladsgroup@cumin1001: START - Cookbook sre.hosts.downtime for 1 day, 0:00:00 on db2176.codfw.wmnet with reason: Maintenance
14:14 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db2174 (T312863)', diff saved to https://phabricator.wikimedia.org/P34518 and previous config saved to /var/cache/conftool/dbconfig/20220912-141405-ladsgroup.json
14:05 btullis@cumin1001: END (PASS) - Cookbook sre.hosts.reboot-single (exit_code=0) for host an-worker1098.eqiad.wmnet
14:02 volans@cumin1001: END (FAIL) - Cookbook sre.hosts.decommission (exit_code=1) for hosts wtp[1028-1030]
14:02 volans@cumin1001: END (PASS) - Cookbook sre.dns.netbox (exit_code=0)
13:58 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db2174', diff saved to https://phabricator.wikimedia.org/P34517 and previous config saved to /var/cache/conftool/dbconfig/20220912-135859-ladsgroup.json
13:57 btullis@cumin1001: START - Cookbook sre.hosts.reboot-single for host an-worker1098.eqiad.wmnet
13:53 volans@cumin1001: START - Cookbook sre.hosts.decommission for hosts wtp[1028-1030]
13:49 bmansurov@deploy1002: Started deploy [airflow-dags/research@b9be20d]: (no justification provided)
13:43 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db2174', diff saved to https://phabricator.wikimedia.org/P34516 and previous config saved to /var/cache/conftool/dbconfig/20220912-134353-ladsgroup.json
13:43 Lucas_WMDE: UTC afternoon backport+config window done
13:40 Lucas_WMDE: scap pull on mwdebug1001 to restore good code (confirmed that T317520 affects production)
13:38 marostegui@cumin1001: dbctl commit (dc=all): 'es1021 (re)pooling @ 100%: Repooling after upgrade', diff saved to https://phabricator.wikimedia.org/P34515 and previous config saved to /var/cache/conftool/dbconfig/20220912-133848-root.json
13:35 Lucas_WMDE: manually applying gerrit:830691 on mwdebug1001 to test if T317520 affects production (expected to cause getExpensiveParserFunctionLimit-related logstash errors)
13:28 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db2174 (T312863)', diff saved to https://phabricator.wikimedia.org/P34514 and previous config saved to /var/cache/conftool/dbconfig/20220912-132846-ladsgroup.json
12:53 marostegui@cumin1001: dbctl commit (dc=all): 'es1021 (re)pooling @ 25%: Repooling after upgrade', diff saved to https://phabricator.wikimedia.org/P34511 and previous config saved to /var/cache/conftool/dbconfig/20220912-125333-root.json
12:38 marostegui@cumin1001: dbctl commit (dc=all): 'es1021 (re)pooling @ 10%: Repooling after upgrade', diff saved to https://phabricator.wikimedia.org/P34510 and previous config saved to /var/cache/conftool/dbconfig/20220912-123828-root.json
12:34 btullis@cumin1001: END (PASS) - Cookbook sre.hosts.reboot-single (exit_code=0) for host an-worker1097.eqiad.wmnet
12:26 marostegui@cumin1001: dbctl commit (dc=all): 'es1034 (re)pooling @ 100%: Repooling after upgrade', diff saved to https://phabricator.wikimedia.org/P34509 and previous config saved to /var/cache/conftool/dbconfig/20220912-122654-root.json
12:26 btullis@cumin1001: START - Cookbook sre.hosts.reboot-single for host an-worker1097.eqiad.wmnet
12:23 marostegui@cumin1001: dbctl commit (dc=all): 'es1021 (re)pooling @ 5%: Repooling after upgrade', diff saved to https://phabricator.wikimedia.org/P34508 and previous config saved to /var/cache/conftool/dbconfig/20220912-122323-root.json
12:22 ladsgroup@cumin1001: dbctl commit (dc=all): 'Depooling db1101:3317 (T314041)', diff saved to https://phabricator.wikimedia.org/P34507 and previous config saved to /var/cache/conftool/dbconfig/20220912-122242-ladsgroup.json
12:22 ladsgroup@cumin1001: END (PASS) - Cookbook sre.hosts.downtime (exit_code=0) for 1 day, 0:00:00 on db1101.eqiad.wmnet with reason: Maintenance
12:22 ladsgroup@cumin1001: START - Cookbook sre.hosts.downtime for 1 day, 0:00:00 on db1101.eqiad.wmnet with reason: Maintenance
12:22 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db1098:3317 (T314041)', diff saved to https://phabricator.wikimedia.org/P34506 and previous config saved to /var/cache/conftool/dbconfig/20220912-122221-ladsgroup.json
12:16 btullis@cumin1001: END (PASS) - Cookbook sre.hosts.reboot-single (exit_code=0) for host an-worker1096.eqiad.wmnet
12:11 marostegui@cumin1001: dbctl commit (dc=all): 'es1034 (re)pooling @ 75%: Repooling after upgrade', diff saved to https://phabricator.wikimedia.org/P34505 and previous config saved to /var/cache/conftool/dbconfig/20220912-121150-root.json
12:08 marostegui@cumin1001: dbctl commit (dc=all): 'es1021 (re)pooling @ 3%: Repooling after upgrade', diff saved to https://phabricator.wikimedia.org/P34504 and previous config saved to /var/cache/conftool/dbconfig/20220912-120818-root.json
12:08 btullis@cumin1001: START - Cookbook sre.hosts.reboot-single for host an-worker1096.eqiad.wmnet
12:07 btullis@cumin1001: END (FAIL) - Cookbook sre.hosts.reboot-single (exit_code=99) for host an-worker1146.eqiad.wmnet
12:07 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db1098:3317', diff saved to https://phabricator.wikimedia.org/P34503 and previous config saved to /var/cache/conftool/dbconfig/20220912-120715-ladsgroup.json
11:56 marostegui@cumin1001: dbctl commit (dc=all): 'es1034 (re)pooling @ 50%: Repooling after upgrade', diff saved to https://phabricator.wikimedia.org/P34502 and previous config saved to /var/cache/conftool/dbconfig/20220912-115645-root.json
11:53 marostegui@cumin1001: dbctl commit (dc=all): 'es1021 (re)pooling @ 2%: Repooling after upgrade', diff saved to https://phabricator.wikimedia.org/P34501 and previous config saved to /var/cache/conftool/dbconfig/20220912-115313-root.json
11:52 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db1098:3317', diff saved to https://phabricator.wikimedia.org/P34500 and previous config saved to /var/cache/conftool/dbconfig/20220912-115208-ladsgroup.json
11:41 marostegui@cumin1001: dbctl commit (dc=all): 'es1034 (re)pooling @ 25%: Repooling after upgrade', diff saved to https://phabricator.wikimedia.org/P34499 and previous config saved to /var/cache/conftool/dbconfig/20220912-114140-root.json
11:38 marostegui@cumin1001: dbctl commit (dc=all): 'es1021 (re)pooling @ 1%: Repooling after upgrade', diff saved to https://phabricator.wikimedia.org/P34498 and previous config saved to /var/cache/conftool/dbconfig/20220912-113808-root.json
11:37 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db1098:3317 (T314041)', diff saved to https://phabricator.wikimedia.org/P34497 and previous config saved to /var/cache/conftool/dbconfig/20220912-113702-ladsgroup.json
11:16 btullis@cumin1001: END (PASS) - Cookbook sre.hadoop.init-hadoop-workers (exit_code=0) for hosts an-worker[1143-1148].eqiad.wmnet
11:15 btullis@cumin1001: END (PASS) - Cookbook sre.hosts.reboot-single (exit_code=0) for host dse-k8s-etcd1001.eqiad.wmnet
11:14 marostegui@cumin1001: dbctl commit (dc=all): 'es1033 (re)pooling @ 100%: Repooling for warm up after upgrade', diff saved to https://phabricator.wikimedia.org/P34493 and previous config saved to /var/cache/conftool/dbconfig/20220912-111442-root.json
11:14 marostegui@cumin1001: dbctl commit (dc=all): 'Set es1020 with weight 0 T317522', diff saved to https://phabricator.wikimedia.org/P34492 and previous config saved to /var/cache/conftool/dbconfig/20220912-111424-root.json
11:13 marostegui@cumin1001: END (PASS) - Cookbook sre.hosts.downtime (exit_code=0) for 1:00:00 on 6 hosts with reason: Primary switchover es4 T317522
11:13 marostegui@cumin1001: START - Cookbook sre.hosts.downtime for 1:00:00 on 6 hosts with reason: Primary switchover es4 T317522
11:12 btullis@cumin1001: START - Cookbook sre.hadoop.init-hadoop-workers for hosts an-worker[1143-1148].eqiad.wmnet
11:11 btullis@cumin1001: START - Cookbook sre.hosts.reboot-single for host dse-k8s-etcd1001.eqiad.wmnet
11:11 marostegui@cumin1001: dbctl commit (dc=all): 'es1034 (re)pooling @ 5%: Repooling after upgrade', diff saved to https://phabricator.wikimedia.org/P34491 and previous config saved to /var/cache/conftool/dbconfig/20220912-111130-root.json
11:10 btullis@cumin1001: END (PASS) - Cookbook sre.hadoop.init-hadoop-workers (exit_code=0) for hosts an-worker1142.eqiad.wmnet
11:09 btullis@cumin1001: START - Cookbook sre.hadoop.init-hadoop-workers for hosts an-worker1142.eqiad.wmnet
11:08 btullis@cumin1001: END (PASS) - Cookbook sre.hosts.reboot-single (exit_code=0) for host an-worker1101.eqiad.wmnet
11:04 moritzm: updated bullseye install image for 11.5 release T317416
10:59 btullis@cumin1001: START - Cookbook sre.hosts.reboot-single for host an-worker1101.eqiad.wmnet
10:59 marostegui@cumin1001: dbctl commit (dc=all): 'es1033 (re)pooling @ 75%: Repooling for warm up after upgrade', diff saved to https://phabricator.wikimedia.org/P34490 and previous config saved to /var/cache/conftool/dbconfig/20220912-105937-root.json
10:59 btullis@cumin1001: END (PASS) - Cookbook sre.hosts.reboot-single (exit_code=0) for host an-worker1100.eqiad.wmnet
10:58 ladsgroup@cumin1001: dbctl commit (dc=all): 'Depooling db2108 (T314041)', diff saved to https://phabricator.wikimedia.org/P34489 and previous config saved to /var/cache/conftool/dbconfig/20220912-105841-ladsgroup.json
10:58 ladsgroup@cumin1001: END (PASS) - Cookbook sre.hosts.downtime (exit_code=0) for 1 day, 0:00:00 on db2108.codfw.wmnet with reason: Maintenance
10:58 ladsgroup@cumin1001: START - Cookbook sre.hosts.downtime for 1 day, 0:00:00 on db2108.codfw.wmnet with reason: Maintenance
10:56 marostegui@cumin1001: dbctl commit (dc=all): 'es1034 (re)pooling @ 3%: Repooling after upgrade', diff saved to https://phabricator.wikimedia.org/P34488 and previous config saved to /var/cache/conftool/dbconfig/20220912-105625-root.json
10:55 topranks: re-pooliong esams after successful upgrade of core router cr3-esams T295690
10:50 btullis@cumin1001: START - Cookbook sre.hosts.reboot-single for host an-worker1100.eqiad.wmnet
10:44 marostegui@cumin1001: dbctl commit (dc=all): 'es1033 (re)pooling @ 50%: Repooling for warm up after upgrade', diff saved to https://phabricator.wikimedia.org/P34487 and previous config saved to /var/cache/conftool/dbconfig/20220912-104432-root.json
10:41 marostegui@cumin1001: dbctl commit (dc=all): 'es1034 (re)pooling @ 1%: Repooling after upgrade', diff saved to https://phabricator.wikimedia.org/P34486 and previous config saved to /var/cache/conftool/dbconfig/20220912-104120-root.json
10:34 marostegui@cumin1001: dbctl commit (dc=all): 'Depool es1034', diff saved to https://phabricator.wikimedia.org/P34485 and previous config saved to /var/cache/conftool/dbconfig/20220912-103428-root.json
10:33 btullis@cumin1001: END (PASS) - Cookbook sre.hosts.reboot-single (exit_code=0) for host an-worker1099.eqiad.wmnet
10:29 marostegui@cumin1001: dbctl commit (dc=all): 'es1033 (re)pooling @ 25%: Repooling for warm up after upgrade', diff saved to https://phabricator.wikimedia.org/P34484 and previous config saved to /var/cache/conftool/dbconfig/20220912-102928-root.json
10:26 btullis@cumin1001: START - Cookbook sre.hosts.reboot-single for host an-worker1099.eqiad.wmnet
10:22 bmansurov@deploy1002: Started deploy [airflow-dags/research@b9be20d]: (no justification provided)
10:18 marostegui@cumin1001: dbctl commit (dc=all): 'es1032 (re)pooling @ 100%: Repooling after upgrade', diff saved to https://phabricator.wikimedia.org/P34483 and previous config saved to /var/cache/conftool/dbconfig/20220912-101842-root.json
10:14 marostegui@cumin1001: dbctl commit (dc=all): 'es1033 (re)pooling @ 10%: Repooling for warm up after upgrade', diff saved to https://phabricator.wikimedia.org/P34481 and previous config saved to /var/cache/conftool/dbconfig/20220912-101423-root.json
10:03 marostegui@cumin1001: dbctl commit (dc=all): 'es1032 (re)pooling @ 75%: Repooling after upgrade', diff saved to https://phabricator.wikimedia.org/P34480 and previous config saved to /var/cache/conftool/dbconfig/20220912-100337-root.json
09:59 marostegui@cumin1001: dbctl commit (dc=all): 'es1033 (re)pooling @ 5%: Repooling for warm up after upgrade', diff saved to https://phabricator.wikimedia.org/P34479 and previous config saved to /var/cache/conftool/dbconfig/20220912-095918-root.json
09:48 marostegui@cumin1001: dbctl commit (dc=all): 'es1032 (re)pooling @ 50%: Repooling after upgrade', diff saved to https://phabricator.wikimedia.org/P34478 and previous config saved to /var/cache/conftool/dbconfig/20220912-094832-root.json
09:48 marostegui@cumin1001: dbctl commit (dc=all): 'Depool es1033', diff saved to https://phabricator.wikimedia.org/P34477 and previous config saved to /var/cache/conftool/dbconfig/20220912-094818-root.json
09:45 cmooney@cumin1001: END (PASS) - Cookbook sre.hosts.downtime (exit_code=0) for 2:00:00 on cr3-esams,cr3-esams IPv6,re0.cr3-esams.mgmt with reason: router upgrade
09:45 cmooney@cumin1001: START - Cookbook sre.hosts.downtime for 2:00:00 on cr3-esams,cr3-esams IPv6,re0.cr3-esams.mgmt with reason: router upgrade
09:33 marostegui@cumin1001: dbctl commit (dc=all): 'es1032 (re)pooling @ 25%: Repooling after upgrade', diff saved to https://phabricator.wikimedia.org/P34476 and previous config saved to /var/cache/conftool/dbconfig/20220912-093327-root.json
09:33 marostegui@cumin1001: dbctl commit (dc=all): 'es2023 (re)pooling @ 100%: Repooling for warm up after upgrade', diff saved to https://phabricator.wikimedia.org/P34475 and previous config saved to /var/cache/conftool/dbconfig/20220912-093318-root.json
09:31 moritzm: updated buster install image for 10.13 release T317413
09:22 marostegui@cumin1001: dbctl commit (dc=all): 'es2021 (re)pooling @ 100%: Repooling after upgrade', diff saved to https://phabricator.wikimedia.org/P34474 and previous config saved to /var/cache/conftool/dbconfig/20220912-092244-root.json
09:22 volans@cumin1001: END (PASS) - Cookbook sre.dns.netbox (exit_code=0)
09:18 marostegui@cumin1001: dbctl commit (dc=all): 'es1032 (re)pooling @ 10%: Repooling after upgrade', diff saved to https://phabricator.wikimedia.org/P34473 and previous config saved to /var/cache/conftool/dbconfig/20220912-091822-root.json
09:18 marostegui@cumin1001: dbctl commit (dc=all): 'es2023 (re)pooling @ 75%: Repooling for warm up after upgrade', diff saved to https://phabricator.wikimedia.org/P34472 and previous config saved to /var/cache/conftool/dbconfig/20220912-091813-root.json
09:18 btullis@cumin1001: END (PASS) - Cookbook sre.hosts.reboot-single (exit_code=0) for host an-worker1098.eqiad.wmnet
09:09 btullis@cumin1001: START - Cookbook sre.hosts.reboot-single for host an-worker1098.eqiad.wmnet
09:07 marostegui@cumin1001: dbctl commit (dc=all): 'es2021 (re)pooling @ 75%: Repooling after upgrade', diff saved to https://phabricator.wikimedia.org/P34471 and previous config saved to /var/cache/conftool/dbconfig/20220912-090739-root.json
09:03 marostegui@cumin1001: dbctl commit (dc=all): 'es1032 (re)pooling @ 5%: Repooling after upgrade', diff saved to https://phabricator.wikimedia.org/P34470 and previous config saved to /var/cache/conftool/dbconfig/20220912-090317-root.json
09:03 marostegui@cumin1001: dbctl commit (dc=all): 'es2023 (re)pooling @ 50%: Repooling for warm up after upgrade', diff saved to https://phabricator.wikimedia.org/P34469 and previous config saved to /var/cache/conftool/dbconfig/20220912-090308-root.json
08:57 btullis@cumin1001: END (PASS) - Cookbook sre.hosts.reboot-single (exit_code=0) for host an-worker1097.eqiad.wmnet
08:52 marostegui@cumin1001: dbctl commit (dc=all): 'es2021 (re)pooling @ 50%: Repooling after upgrade', diff saved to https://phabricator.wikimedia.org/P34468 and previous config saved to /var/cache/conftool/dbconfig/20220912-085234-root.json
08:48 marostegui@cumin1001: dbctl commit (dc=all): 'es1032 (re)pooling @ 3%: Repooling after upgrade', diff saved to https://phabricator.wikimedia.org/P34467 and previous config saved to /var/cache/conftool/dbconfig/20220912-084812-root.json
08:48 marostegui@cumin1001: dbctl commit (dc=all): 'es2023 (re)pooling @ 25%: Repooling for warm up after upgrade', diff saved to https://phabricator.wikimedia.org/P34466 and previous config saved to /var/cache/conftool/dbconfig/20220912-084803-root.json
08:47 btullis@cumin1001: START - Cookbook sre.hosts.reboot-single for host an-worker1097.eqiad.wmnet
08:45 btullis@cumin1001: END (PASS) - Cookbook sre.hosts.reboot-single (exit_code=0) for host an-worker1096.eqiad.wmnet
08:39 cmooney@cumin1001: END (PASS) - Cookbook sre.hosts.downtime (exit_code=0) for 2:00:00 on cr3-esams,cr3-esams IPv6,re0.cr3-esams.mgmt with reason: router upgrade
08:39 cmooney@cumin1001: START - Cookbook sre.hosts.downtime for 2:00:00 on cr3-esams,cr3-esams IPv6,re0.cr3-esams.mgmt with reason: router upgrade
08:38 btullis@cumin1001: START - Cookbook sre.hosts.reboot-single for host an-worker1096.eqiad.wmnet
08:37 marostegui@cumin1001: dbctl commit (dc=all): 'es2021 (re)pooling @ 25%: Repooling after upgrade', diff saved to https://phabricator.wikimedia.org/P34465 and previous config saved to /var/cache/conftool/dbconfig/20220912-083729-root.json
08:36 cmooney@cumin1001: END (FAIL) - Cookbook sre.hosts.downtime (exit_code=99) for 2:00:00 on cr3-esams,cr3-esams IPv6,cr3-esams.mgmt with reason: router upgrade
08:36 cmooney@cumin1001: START - Cookbook sre.hosts.downtime for 2:00:00 on cr3-esams,cr3-esams IPv6,cr3-esams.mgmt with reason: router upgrade
08:33 marostegui@cumin1001: dbctl commit (dc=all): 'es1032 (re)pooling @ 1%: Repooling after upgrade', diff saved to https://phabricator.wikimedia.org/P34464 and previous config saved to /var/cache/conftool/dbconfig/20220912-083308-root.json
08:32 marostegui@cumin1001: dbctl commit (dc=all): 'es2023 (re)pooling @ 10%: Repooling for warm up after upgrade', diff saved to https://phabricator.wikimedia.org/P34463 and previous config saved to /var/cache/conftool/dbconfig/20220912-083258-root.json
08:22 marostegui@cumin1001: dbctl commit (dc=all): 'es2021 (re)pooling @ 10%: Repooling after upgrade', diff saved to https://phabricator.wikimedia.org/P34462 and previous config saved to /var/cache/conftool/dbconfig/20220912-082224-root.json
08:19 marostegui@cumin1001: dbctl commit (dc=all): 'Depool es1032', diff saved to https://phabricator.wikimedia.org/P34461 and previous config saved to /var/cache/conftool/dbconfig/20220912-081936-root.json
08:17 moritzm: imported jenkins 2.361.1 to thirdparty/ci T317418
08:17 marostegui@cumin1001: dbctl commit (dc=all): 'es2023 (re)pooling @ 5%: Repooling for warm up after upgrade', diff saved to https://phabricator.wikimedia.org/P34460 and previous config saved to /var/cache/conftool/dbconfig/20220912-081754-root.json
08:09 cmooney@cumin1001: END (PASS) - Cookbook sre.network.cf (exit_code=0)
08:07 marostegui@cumin1001: dbctl commit (dc=all): 'es2021 (re)pooling @ 5%: Repooling after upgrade', diff saved to https://phabricator.wikimedia.org/P34459 and previous config saved to /var/cache/conftool/dbconfig/20220912-080719-root.json
08:06 marostegui@cumin1001: dbctl commit (dc=all): 'Depool es2023 T317508', diff saved to https://phabricator.wikimedia.org/P34458 and previous config saved to /var/cache/conftool/dbconfig/20220912-080602-root.json
08:04 marostegui@cumin1001: dbctl commit (dc=all): 'Promote es2024 to es5 codfw primary T317508', diff saved to https://phabricator.wikimedia.org/P34457 and previous config saved to /var/cache/conftool/dbconfig/20220912-080400-root.json
08:03 marostegui: Starting es5 codfw failover from es2023 to es2024 - T317508
08:01 cmooney@cumin1001: END (PASS) - Cookbook sre.hosts.downtime (exit_code=0) for 2:00:00 on cr3-esams with reason: router upgrade
08:01 elukey: restart kafka on kafka2001 to pick up new PKI settings
08:01 cmooney@cumin1001: START - Cookbook sre.hosts.downtime for 2:00:00 on cr3-esams with reason: router upgrade
08:00 hashar: Restarting CI Jenkins for upgrade T317418
08:00 topranks: de-pooliong esams in advance of upgrade to core router cr3-esams T295690
07:58 elukey@cumin1001: END (PASS) - Cookbook sre.hosts.downtime (exit_code=0) for 0:20:00 on kafka-logging2001.codfw.wmnet with reason: Kafka PKI upgrade
07:57 elukey@cumin1001: START - Cookbook sre.hosts.downtime for 0:20:00 on kafka-logging2001.codfw.wmnet with reason: Kafka PKI upgrade
07:57 marostegui@cumin1001: dbctl commit (dc=all): 'Set es2024 with weight 0 T317508', diff saved to https://phabricator.wikimedia.org/P34456 and previous config saved to /var/cache/conftool/dbconfig/20220912-075739-root.json
07:56 marostegui@cumin1001: END (PASS) - Cookbook sre.hosts.downtime (exit_code=0) for 1:00:00 on 6 hosts with reason: Primary switchover es5 T317508
07:56 marostegui@cumin1001: START - Cookbook sre.hosts.downtime for 1:00:00 on 6 hosts with reason: Primary switchover es5 T317508
07:47 hashar: Upgraded Jenkins instances from 2.346.1 to 2.346.3 # T317418
07:43 marostegui@cumin1001: dbctl commit (dc=all): 'Depool es2021 T317507', diff saved to https://phabricator.wikimedia.org/P34455 and previous config saved to /var/cache/conftool/dbconfig/20220912-074258-root.json
07:41 marostegui@cumin1001: dbctl commit (dc=all): 'Promote es2020 to es4 primary and set section read-write T317507', diff saved to https://phabricator.wikimedia.org/P34454 and previous config saved to /var/cache/conftool/dbconfig/20220912-074100-root.json
07:39 marostegui: Starting es4 codfw failover from es2021 to es2020 - T317507
07:34 marostegui@cumin1001: dbctl commit (dc=all): 'Set es2020 with weight 0 T317507', diff saved to https://phabricator.wikimedia.org/P34453 and previous config saved to /var/cache/conftool/dbconfig/20220912-073408-root.json
07:33 marostegui@cumin1001: END (PASS) - Cookbook sre.hosts.downtime (exit_code=0) for 1:00:00 on 6 hosts with reason: Primary switchover es4 T317507
07:33 marostegui@cumin1001: START - Cookbook sre.hosts.downtime for 1:00:00 on 6 hosts with reason: Primary switchover es4 T317507
07:31 ladsgroup@cumin1001: END (PASS) - Cookbook sre.hosts.downtime (exit_code=0) for 1 day, 0:00:00 on db2098.codfw.wmnet with reason: Maintenance
07:31 ladsgroup@cumin1001: START - Cookbook sre.hosts.downtime for 1 day, 0:00:00 on db2098.codfw.wmnet with reason: Maintenance
07:29 ladsgroup@cumin1001: dbctl commit (dc=all): 'Depooling db2174 (T312863)', diff saved to https://phabricator.wikimedia.org/P34452 and previous config saved to /var/cache/conftool/dbconfig/20220912-072931-ladsgroup.json
07:29 ladsgroup@cumin1001: END (PASS) - Cookbook sre.hosts.downtime (exit_code=0) for 1 day, 0:00:00 on db2174.codfw.wmnet with reason: Maintenance
07:29 ladsgroup@cumin1001: START - Cookbook sre.hosts.downtime for 1 day, 0:00:00 on db2174.codfw.wmnet with reason: Maintenance
07:29 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db2173 (T312863)', diff saved to https://phabricator.wikimedia.org/P34450 and previous config saved to /var/cache/conftool/dbconfig/20220912-072909-ladsgroup.json
07:18 marostegui@cumin1001: dbctl commit (dc=all): 'es2024 (re)pooling @ 100%: Repooling after upgrade', diff saved to https://phabricator.wikimedia.org/P34449 and previous config saved to /var/cache/conftool/dbconfig/20220912-071829-root.json
07:17 ladsgroup@cumin1001: dbctl commit (dc=all): 'Depooling db1098:3317 (T314041)', diff saved to https://phabricator.wikimedia.org/P34448 and previous config saved to /var/cache/conftool/dbconfig/20220912-071700-ladsgroup.json
07:16 ladsgroup@cumin1001: END (PASS) - Cookbook sre.hosts.downtime (exit_code=0) for 1 day, 0:00:00 on db1098.eqiad.wmnet with reason: Maintenance
07:16 ladsgroup@cumin1001: START - Cookbook sre.hosts.downtime for 1 day, 0:00:00 on db1098.eqiad.wmnet with reason: Maintenance
07:14 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db2173', diff saved to https://phabricator.wikimedia.org/P34447 and previous config saved to /var/cache/conftool/dbconfig/20220912-071403-ladsgroup.json
07:03 marostegui@cumin1001: dbctl commit (dc=all): 'es2024 (re)pooling @ 75%: Repooling after upgrade', diff saved to https://phabricator.wikimedia.org/P34446 and previous config saved to /var/cache/conftool/dbconfig/20220912-070324-root.json
06:58 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db2173', diff saved to https://phabricator.wikimedia.org/P34445 and previous config saved to /var/cache/conftool/dbconfig/20220912-065856-ladsgroup.json
06:50 marostegui@cumin1001: dbctl commit (dc=all): 'es2020 (re)pooling @ 100%: Repooling for warm up after upgrade', diff saved to https://phabricator.wikimedia.org/P34444 and previous config saved to /var/cache/conftool/dbconfig/20220912-065028-root.json
06:48 marostegui@cumin1001: dbctl commit (dc=all): 'es2024 (re)pooling @ 50%: Repooling after upgrade', diff saved to https://phabricator.wikimedia.org/P34443 and previous config saved to /var/cache/conftool/dbconfig/20220912-064819-root.json
06:47 moritzm: installing 5.10.136 updates on buster systems running 5.10
06:43 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db2173 (T312863)', diff saved to https://phabricator.wikimedia.org/P34442 and previous config saved to /var/cache/conftool/dbconfig/20220912-064350-ladsgroup.json
06:35 marostegui@cumin1001: dbctl commit (dc=all): 'es2020 (re)pooling @ 75%: Repooling for warm up after upgrade', diff saved to https://phabricator.wikimedia.org/P34441 and previous config saved to /var/cache/conftool/dbconfig/20220912-063523-root.json
06:33 marostegui@cumin1001: dbctl commit (dc=all): 'es2024 (re)pooling @ 25%: Repooling after upgrade', diff saved to https://phabricator.wikimedia.org/P34440 and previous config saved to /var/cache/conftool/dbconfig/20220912-063314-root.json
06:20 marostegui@cumin1001: dbctl commit (dc=all): 'es2020 (re)pooling @ 50%: Repooling for warm up after upgrade', diff saved to https://phabricator.wikimedia.org/P34439 and previous config saved to /var/cache/conftool/dbconfig/20220912-062018-root.json
06:18 marostegui@cumin1001: dbctl commit (dc=all): 'es2024 (re)pooling @ 10%: Repooling after upgrade', diff saved to https://phabricator.wikimedia.org/P34438 and previous config saved to /var/cache/conftool/dbconfig/20220912-061810-root.json
06:05 marostegui@cumin1001: dbctl commit (dc=all): 'es2020 (re)pooling @ 25%: Repooling for warm up after upgrade', diff saved to https://phabricator.wikimedia.org/P34437 and previous config saved to /var/cache/conftool/dbconfig/20220912-060513-root.json
06:03 marostegui@cumin1001: dbctl commit (dc=all): 'es2024 (re)pooling @ 5%: Repooling after upgrade', diff saved to https://phabricator.wikimedia.org/P34436 and previous config saved to /var/cache/conftool/dbconfig/20220912-060305-root.json
05:51 marostegui@cumin1001: dbctl commit (dc=all): 'Depool es2024 for upgrade', diff saved to https://phabricator.wikimedia.org/P34435 and previous config saved to /var/cache/conftool/dbconfig/20220912-055101-root.json
05:50 marostegui@cumin1001: dbctl commit (dc=all): 'es2020 (re)pooling @ 10%: Repooling for warm up after upgrade', diff saved to https://phabricator.wikimedia.org/P34434 and previous config saved to /var/cache/conftool/dbconfig/20220912-055008-root.json
05:35 marostegui@cumin1001: dbctl commit (dc=all): 'es2020 (re)pooling @ 5%: Repooling for warm up after upgrade', diff saved to https://phabricator.wikimedia.org/P34433 and previous config saved to /var/cache/conftool/dbconfig/20220912-053504-root.json
05:23 marostegui@cumin1001: END (PASS) - Cookbook sre.hosts.downtime (exit_code=0) for 1:00:00 on 6 hosts with reason: Primary switchover es4 T317507
05:22 marostegui@cumin1001: START - Cookbook sre.hosts.downtime for 1:00:00 on 6 hosts with reason: Primary switchover es4 T317507
05:21 ladsgroup@cumin1001: END (PASS) - Cookbook sre.hosts.downtime (exit_code=0) for 1 day, 0:00:00 on db1145.eqiad.wmnet with reason: Maintenance
05:21 ladsgroup@cumin1001: START - Cookbook sre.hosts.downtime for 1 day, 0:00:00 on db1145.eqiad.wmnet with reason: Maintenance
05:21 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db1144:3314 (T314041)', diff saved to https://phabricator.wikimedia.org/P34432 and previous config saved to /var/cache/conftool/dbconfig/20220912-052143-ladsgroup.json
05:21 marostegui: dbmaint Reboot es2020 for kernel upgrade T317507
05:19 marostegui@cumin1001: dbctl commit (dc=all): 'Depool es2020 for upgrade T317507', diff saved to https://phabricator.wikimedia.org/P34431 and previous config saved to /var/cache/conftool/dbconfig/20220912-051906-root.json
05:06 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db1144:3314', diff saved to https://phabricator.wikimedia.org/P34430 and previous config saved to /var/cache/conftool/dbconfig/20220912-050636-ladsgroup.json
04:51 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db1144:3314', diff saved to https://phabricator.wikimedia.org/P34429 and previous config saved to /var/cache/conftool/dbconfig/20220912-045130-ladsgroup.json
04:36 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db1144:3314 (T314041)', diff saved to https://phabricator.wikimedia.org/P34428 and previous config saved to /var/cache/conftool/dbconfig/20220912-043624-ladsgroup.json
02:06 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db2179 (T314041)', diff saved to https://phabricator.wikimedia.org/P34427 and previous config saved to /var/cache/conftool/dbconfig/20220912-020638-ladsgroup.json
01:51 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db2179', diff saved to https://phabricator.wikimedia.org/P34426 and previous config saved to /var/cache/conftool/dbconfig/20220912-015131-ladsgroup.json
01:36 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db2179', diff saved to https://phabricator.wikimedia.org/P34425 and previous config saved to /var/cache/conftool/dbconfig/20220912-013625-ladsgroup.json
01:21 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db2179 (T314041)', diff saved to https://phabricator.wikimedia.org/P34424 and previous config saved to /var/cache/conftool/dbconfig/20220912-012118-ladsgroup.json
00:49 ladsgroup@cumin1001: dbctl commit (dc=all): 'Depooling db2173 (T312863)', diff saved to https://phabricator.wikimedia.org/P34423 and previous config saved to /var/cache/conftool/dbconfig/20220912-004952-ladsgroup.json
00:49 ladsgroup@cumin1001: END (PASS) - Cookbook sre.hosts.downtime (exit_code=0) for 2 days, 0:00:00 on db2094.codfw.wmnet with reason: Maintenance
00:49 ladsgroup@cumin1001: START - Cookbook sre.hosts.downtime for 2 days, 0:00:00 on db2094.codfw.wmnet with reason: Maintenance
00:49 ladsgroup@cumin1001: END (PASS) - Cookbook sre.hosts.downtime (exit_code=0) for 1 day, 0:00:00 on db2173.codfw.wmnet with reason: Maintenance
00:49 ladsgroup@cumin1001: START - Cookbook sre.hosts.downtime for 1 day, 0:00:00 on db2173.codfw.wmnet with reason: Maintenance
00:49 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db2170:3311 (T312863)', diff saved to https://phabricator.wikimedia.org/P34422 and previous config saved to /var/cache/conftool/dbconfig/20220912-004915-ladsgroup.json
00:34 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db2170:3311', diff saved to https://phabricator.wikimedia.org/P34421 and previous config saved to /var/cache/conftool/dbconfig/20220912-003409-ladsgroup.json
00:19 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db2170:3311', diff saved to https://phabricator.wikimedia.org/P34420 and previous config saved to /var/cache/conftool/dbconfig/20220912-001902-ladsgroup.json
00:03 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db2170:3311 (T312863)', diff saved to https://phabricator.wikimedia.org/P34419 and previous config saved to /var/cache/conftool/dbconfig/20220912-000356-ladsgroup.json
2022-09-11
17:56 ladsgroup@cumin1001: dbctl commit (dc=all): 'Depooling db2170:3311 (T312863)', diff saved to https://phabricator.wikimedia.org/P34418 and previous config saved to /var/cache/conftool/dbconfig/20220911-175643-ladsgroup.json
17:56 ladsgroup@cumin1001: END (PASS) - Cookbook sre.hosts.downtime (exit_code=0) for 1 day, 0:00:00 on db2170.codfw.wmnet with reason: Maintenance
17:56 ladsgroup@cumin1001: START - Cookbook sre.hosts.downtime for 1 day, 0:00:00 on db2170.codfw.wmnet with reason: Maintenance
17:56 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db2167:3311 (T312863)', diff saved to https://phabricator.wikimedia.org/P34417 and previous config saved to /var/cache/conftool/dbconfig/20220911-175621-ladsgroup.json
17:41 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db2167:3311', diff saved to https://phabricator.wikimedia.org/P34416 and previous config saved to /var/cache/conftool/dbconfig/20220911-174114-ladsgroup.json
17:26 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db2167:3311', diff saved to https://phabricator.wikimedia.org/P34415 and previous config saved to /var/cache/conftool/dbconfig/20220911-172608-ladsgroup.json
17:11 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db2167:3311 (T312863)', diff saved to https://phabricator.wikimedia.org/P34414 and previous config saved to /var/cache/conftool/dbconfig/20220911-171102-ladsgroup.json
12:09 bmansurov@deploy1002: Started deploy [airflow-dags/research@b9be20d]: (no justification provided)
11:48 ladsgroup@cumin1001: dbctl commit (dc=all): 'Depooling db1144:3314 (T314041)', diff saved to https://phabricator.wikimedia.org/P34412 and previous config saved to /var/cache/conftool/dbconfig/20220911-114850-ladsgroup.json
11:48 ladsgroup@cumin1001: END (PASS) - Cookbook sre.hosts.downtime (exit_code=0) for 1 day, 0:00:00 on db1144.eqiad.wmnet with reason: Maintenance
11:48 ladsgroup@cumin1001: START - Cookbook sre.hosts.downtime for 1 day, 0:00:00 on db1144.eqiad.wmnet with reason: Maintenance
11:48 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db1142 (T314041)', diff saved to https://phabricator.wikimedia.org/P34411 and previous config saved to /var/cache/conftool/dbconfig/20220911-114829-ladsgroup.json
11:33 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db1142', diff saved to https://phabricator.wikimedia.org/P34410 and previous config saved to /var/cache/conftool/dbconfig/20220911-113323-ladsgroup.json
11:26 bmansurov@deploy1002: Started deploy [airflow-dags/research@b9be20d]: (no justification provided)
11:18 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db1142', diff saved to https://phabricator.wikimedia.org/P34409 and previous config saved to /var/cache/conftool/dbconfig/20220911-111816-ladsgroup.json
11:03 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db1142 (T314041)', diff saved to https://phabricator.wikimedia.org/P34408 and previous config saved to /var/cache/conftool/dbconfig/20220911-110310-ladsgroup.json
11:02 ladsgroup@cumin1001: dbctl commit (dc=all): 'Depooling db2167:3311 (T312863)', diff saved to https://phabricator.wikimedia.org/P34407 and previous config saved to /var/cache/conftool/dbconfig/20220911-110228-ladsgroup.json
11:02 ladsgroup@cumin1001: END (PASS) - Cookbook sre.hosts.downtime (exit_code=0) for 1 day, 0:00:00 on db2167.codfw.wmnet with reason: Maintenance
11:02 ladsgroup@cumin1001: START - Cookbook sre.hosts.downtime for 1 day, 0:00:00 on db2167.codfw.wmnet with reason: Maintenance
11:02 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db2153 (T312863)', diff saved to https://phabricator.wikimedia.org/P34406 and previous config saved to /var/cache/conftool/dbconfig/20220911-110207-ladsgroup.json
10:56 bmansurov@deploy1002: Started deploy [airflow-dags/research@b9be20d]: (no justification provided)
10:47 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db2153', diff saved to https://phabricator.wikimedia.org/P34405 and previous config saved to /var/cache/conftool/dbconfig/20220911-104700-ladsgroup.json
10:31 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db2153', diff saved to https://phabricator.wikimedia.org/P34404 and previous config saved to /var/cache/conftool/dbconfig/20220911-103154-ladsgroup.json
10:16 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db2153 (T312863)', diff saved to https://phabricator.wikimedia.org/P34403 and previous config saved to /var/cache/conftool/dbconfig/20220911-101647-ladsgroup.json
10:06 bmansurov@deploy1002: Started deploy [airflow-dags/research@b9be20d]: (no justification provided)
08:45 ladsgroup@cumin1001: dbctl commit (dc=all): 'Depooling db2179 (T314041)', diff saved to https://phabricator.wikimedia.org/P34402 and previous config saved to /var/cache/conftool/dbconfig/20220911-084529-ladsgroup.json
08:45 ladsgroup@cumin1001: END (PASS) - Cookbook sre.hosts.downtime (exit_code=0) for 1 day, 0:00:00 on db2179.codfw.wmnet with reason: Maintenance
08:45 ladsgroup@cumin1001: START - Cookbook sre.hosts.downtime for 1 day, 0:00:00 on db2179.codfw.wmnet with reason: Maintenance
04:19 ladsgroup@cumin1001: dbctl commit (dc=all): 'Depooling db2153 (T312863)', diff saved to https://phabricator.wikimedia.org/P34401 and previous config saved to /var/cache/conftool/dbconfig/20220911-041936-ladsgroup.json
04:19 ladsgroup@cumin1001: END (PASS) - Cookbook sre.hosts.downtime (exit_code=0) for 1 day, 0:00:00 on db2153.codfw.wmnet with reason: Maintenance
04:19 ladsgroup@cumin1001: START - Cookbook sre.hosts.downtime for 1 day, 0:00:00 on db2153.codfw.wmnet with reason: Maintenance
04:19 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db2146 (T312863)', diff saved to https://phabricator.wikimedia.org/P34400 and previous config saved to /var/cache/conftool/dbconfig/20220911-041914-ladsgroup.json
04:04 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db2146', diff saved to https://phabricator.wikimedia.org/P34399 and previous config saved to /var/cache/conftool/dbconfig/20220911-040407-ladsgroup.json
03:49 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db2146', diff saved to https://phabricator.wikimedia.org/P34398 and previous config saved to /var/cache/conftool/dbconfig/20220911-034901-ladsgroup.json
03:33 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db2146 (T312863)', diff saved to https://phabricator.wikimedia.org/P34397 and previous config saved to /var/cache/conftool/dbconfig/20220911-033355-ladsgroup.json
2022-09-10
21:33 ladsgroup@cumin1001: dbctl commit (dc=all): 'Depooling db2146 (T312863)', diff saved to https://phabricator.wikimedia.org/P34396 and previous config saved to /var/cache/conftool/dbconfig/20220910-213300-ladsgroup.json
21:32 ladsgroup@cumin1001: END (PASS) - Cookbook sre.hosts.downtime (exit_code=0) for 1 day, 0:00:00 on db2146.codfw.wmnet with reason: Maintenance
21:32 ladsgroup@cumin1001: START - Cookbook sre.hosts.downtime for 1 day, 0:00:00 on db2146.codfw.wmnet with reason: Maintenance
21:32 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db2145 (T312863)', diff saved to https://phabricator.wikimedia.org/P34395 and previous config saved to /var/cache/conftool/dbconfig/20220910-213238-ladsgroup.json
21:17 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db2145', diff saved to https://phabricator.wikimedia.org/P34394 and previous config saved to /var/cache/conftool/dbconfig/20220910-211732-ladsgroup.json
21:02 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db2145', diff saved to https://phabricator.wikimedia.org/P34393 and previous config saved to /var/cache/conftool/dbconfig/20220910-210225-ladsgroup.json
20:47 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db2145 (T312863)', diff saved to https://phabricator.wikimedia.org/P34392 and previous config saved to /var/cache/conftool/dbconfig/20220910-204719-ladsgroup.json
19:14 ladsgroup@cumin1001: dbctl commit (dc=all): 'Depooling db1142 (T314041)', diff saved to https://phabricator.wikimedia.org/P34391 and previous config saved to /var/cache/conftool/dbconfig/20220910-191455-ladsgroup.json
19:14 ladsgroup@cumin1001: END (PASS) - Cookbook sre.hosts.downtime (exit_code=0) for 1 day, 0:00:00 on db1142.eqiad.wmnet with reason: Maintenance
19:14 ladsgroup@cumin1001: START - Cookbook sre.hosts.downtime for 1 day, 0:00:00 on db1142.eqiad.wmnet with reason: Maintenance
19:14 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db1141 (T314041)', diff saved to https://phabricator.wikimedia.org/P34390 and previous config saved to /var/cache/conftool/dbconfig/20220910-191434-ladsgroup.json
18:59 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db1141', diff saved to https://phabricator.wikimedia.org/P34389 and previous config saved to /var/cache/conftool/dbconfig/20220910-185927-ladsgroup.json
18:44 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db1141', diff saved to https://phabricator.wikimedia.org/P34388 and previous config saved to /var/cache/conftool/dbconfig/20220910-184421-ladsgroup.json
18:29 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db1141 (T314041)', diff saved to https://phabricator.wikimedia.org/P34387 and previous config saved to /var/cache/conftool/dbconfig/20220910-182914-ladsgroup.json
17:41 ladsgroup@cumin1001: END (PASS) - Cookbook sre.hosts.downtime (exit_code=0) for 1 day, 0:00:00 on db2139.codfw.wmnet with reason: Maintenance
17:41 ladsgroup@cumin1001: START - Cookbook sre.hosts.downtime for 1 day, 0:00:00 on db2139.codfw.wmnet with reason: Maintenance
17:41 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db2137:3314 (T314041)', diff saved to https://phabricator.wikimedia.org/P34386 and previous config saved to /var/cache/conftool/dbconfig/20220910-174141-ladsgroup.json
17:26 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db2137:3314', diff saved to https://phabricator.wikimedia.org/P34385 and previous config saved to /var/cache/conftool/dbconfig/20220910-172635-ladsgroup.json
17:11 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db2137:3314', diff saved to https://phabricator.wikimedia.org/P34384 and previous config saved to /var/cache/conftool/dbconfig/20220910-171127-ladsgroup.json
16:56 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db2137:3314 (T314041)', diff saved to https://phabricator.wikimedia.org/P34383 and previous config saved to /var/cache/conftool/dbconfig/20220910-165621-ladsgroup.json
14:56 ladsgroup@cumin1001: dbctl commit (dc=all): 'Depooling db2145 (T312863)', diff saved to https://phabricator.wikimedia.org/P34382 and previous config saved to /var/cache/conftool/dbconfig/20220910-145558-ladsgroup.json
14:55 ladsgroup@cumin1001: END (PASS) - Cookbook sre.hosts.downtime (exit_code=0) for 1 day, 0:00:00 on db2145.codfw.wmnet with reason: Maintenance
14:55 ladsgroup@cumin1001: START - Cookbook sre.hosts.downtime for 1 day, 0:00:00 on db2145.codfw.wmnet with reason: Maintenance
12:11 ladsgroup@cumin1001: END (PASS) - Cookbook sre.hosts.downtime (exit_code=0) for 1 day, 0:00:00 on dbstore1003.eqiad.wmnet with reason: Maintenance
12:11 ladsgroup@cumin1001: START - Cookbook sre.hosts.downtime for 1 day, 0:00:00 on dbstore1003.eqiad.wmnet with reason: Maintenance
12:11 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db1186 (T312863)', diff saved to https://phabricator.wikimedia.org/P34381 and previous config saved to /var/cache/conftool/dbconfig/20220910-121124-ladsgroup.json
11:56 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db1186', diff saved to https://phabricator.wikimedia.org/P34380 and previous config saved to /var/cache/conftool/dbconfig/20220910-115617-ladsgroup.json
11:41 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db1186', diff saved to https://phabricator.wikimedia.org/P34379 and previous config saved to /var/cache/conftool/dbconfig/20220910-114111-ladsgroup.json
11:26 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db1186 (T312863)', diff saved to https://phabricator.wikimedia.org/P34378 and previous config saved to /var/cache/conftool/dbconfig/20220910-112605-ladsgroup.json
09:37 ladsgroup@cumin1001: END (PASS) - Cookbook sre.hosts.downtime (exit_code=0) for 1 day, 0:00:00 on db2141.codfw.wmnet with reason: Maintenance
09:37 ladsgroup@cumin1001: START - Cookbook sre.hosts.downtime for 1 day, 0:00:00 on db2141.codfw.wmnet with reason: Maintenance
09:37 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db2130 (T312863)', diff saved to https://phabricator.wikimedia.org/P34377 and previous config saved to /var/cache/conftool/dbconfig/20220910-093703-ladsgroup.json
09:21 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db2130', diff saved to https://phabricator.wikimedia.org/P34376 and previous config saved to /var/cache/conftool/dbconfig/20220910-092156-ladsgroup.json
09:06 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db2130', diff saved to https://phabricator.wikimedia.org/P34375 and previous config saved to /var/cache/conftool/dbconfig/20220910-090650-ladsgroup.json
08:51 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db2130 (T312863)', diff saved to https://phabricator.wikimedia.org/P34374 and previous config saved to /var/cache/conftool/dbconfig/20220910-085143-ladsgroup.json
05:24 ladsgroup@cumin1001: dbctl commit (dc=all): 'Depooling db1186 (T312863)', diff saved to https://phabricator.wikimedia.org/P34373 and previous config saved to /var/cache/conftool/dbconfig/20220910-052410-ladsgroup.json
05:24 ladsgroup@cumin1001: END (PASS) - Cookbook sre.hosts.downtime (exit_code=0) for 1 day, 0:00:00 on db1186.eqiad.wmnet with reason: Maintenance
05:23 ladsgroup@cumin1001: START - Cookbook sre.hosts.downtime for 1 day, 0:00:00 on db1186.eqiad.wmnet with reason: Maintenance
05:23 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db1184 (T312863)', diff saved to https://phabricator.wikimedia.org/P34372 and previous config saved to /var/cache/conftool/dbconfig/20220910-052349-ladsgroup.json
05:08 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db1184', diff saved to https://phabricator.wikimedia.org/P34371 and previous config saved to /var/cache/conftool/dbconfig/20220910-050842-ladsgroup.json
04:53 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db1184', diff saved to https://phabricator.wikimedia.org/P34370 and previous config saved to /var/cache/conftool/dbconfig/20220910-045336-ladsgroup.json
04:38 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db1184 (T312863)', diff saved to https://phabricator.wikimedia.org/P34369 and previous config saved to /var/cache/conftool/dbconfig/20220910-043829-ladsgroup.json
02:55 ladsgroup@cumin1001: dbctl commit (dc=all): 'Depooling db2130 (T312863)', diff saved to https://phabricator.wikimedia.org/P34368 and previous config saved to /var/cache/conftool/dbconfig/20220910-025548-ladsgroup.json
02:55 ladsgroup@cumin1001: END (PASS) - Cookbook sre.hosts.downtime (exit_code=0) for 1 day, 0:00:00 on db2130.codfw.wmnet with reason: Maintenance
02:55 ladsgroup@cumin1001: START - Cookbook sre.hosts.downtime for 1 day, 0:00:00 on db2130.codfw.wmnet with reason: Maintenance
02:55 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db2116 (T312863)', diff saved to https://phabricator.wikimedia.org/P34367 and previous config saved to /var/cache/conftool/dbconfig/20220910-025526-ladsgroup.json
02:44 ladsgroup@cumin1001: dbctl commit (dc=all): 'Depooling db1141 (T314041)', diff saved to https://phabricator.wikimedia.org/P34366 and previous config saved to /var/cache/conftool/dbconfig/20220910-024401-ladsgroup.json
02:43 ladsgroup@cumin1001: END (PASS) - Cookbook sre.hosts.downtime (exit_code=0) for 1 day, 0:00:00 on db1141.eqiad.wmnet with reason: Maintenance
02:43 ladsgroup@cumin1001: START - Cookbook sre.hosts.downtime for 1 day, 0:00:00 on db1141.eqiad.wmnet with reason: Maintenance
02:43 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db1121 (T314041)', diff saved to https://phabricator.wikimedia.org/P34365 and previous config saved to /var/cache/conftool/dbconfig/20220910-024339-ladsgroup.json
02:40 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db2116', diff saved to https://phabricator.wikimedia.org/P34364 and previous config saved to /var/cache/conftool/dbconfig/20220910-024019-ladsgroup.json
02:28 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db1121', diff saved to https://phabricator.wikimedia.org/P34363 and previous config saved to /var/cache/conftool/dbconfig/20220910-022833-ladsgroup.json
02:25 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db2116', diff saved to https://phabricator.wikimedia.org/P34362 and previous config saved to /var/cache/conftool/dbconfig/20220910-022513-ladsgroup.json
02:13 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db1121', diff saved to https://phabricator.wikimedia.org/P34361 and previous config saved to /var/cache/conftool/dbconfig/20220910-021326-ladsgroup.json
02:10 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db2116 (T312863)', diff saved to https://phabricator.wikimedia.org/P34360 and previous config saved to /var/cache/conftool/dbconfig/20220910-021007-ladsgroup.json
01:58 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db1121 (T314041)', diff saved to https://phabricator.wikimedia.org/P34359 and previous config saved to /var/cache/conftool/dbconfig/20220910-015820-ladsgroup.json
00:50 ladsgroup@cumin1001: dbctl commit (dc=all): 'Depooling db2137:3314 (T314041)', diff saved to https://phabricator.wikimedia.org/P34358 and previous config saved to /var/cache/conftool/dbconfig/20220910-005046-ladsgroup.json
00:50 ladsgroup@cumin1001: END (PASS) - Cookbook sre.hosts.downtime (exit_code=0) for 1 day, 0:00:00 on db2137.codfw.wmnet with reason: Maintenance
00:50 ladsgroup@cumin1001: START - Cookbook sre.hosts.downtime for 1 day, 0:00:00 on db2137.codfw.wmnet with reason: Maintenance
00:50 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db2106 (T314041)', diff saved to https://phabricator.wikimedia.org/P34357 and previous config saved to /var/cache/conftool/dbconfig/20220910-005025-ladsgroup.json
00:35 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db2106', diff saved to https://phabricator.wikimedia.org/P34356 and previous config saved to /var/cache/conftool/dbconfig/20220910-003518-ladsgroup.json
00:20 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db2106', diff saved to https://phabricator.wikimedia.org/P34355 and previous config saved to /var/cache/conftool/dbconfig/20220910-002012-ladsgroup.json
00:05 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db2106 (T314041)', diff saved to https://phabricator.wikimedia.org/P34354 and previous config saved to /var/cache/conftool/dbconfig/20220910-000504-ladsgroup.json
2022-09-09
22:42 ladsgroup@cumin1001: dbctl commit (dc=all): 'Depooling db1184 (T312863)', diff saved to https://phabricator.wikimedia.org/P34353 and previous config saved to /var/cache/conftool/dbconfig/20220909-224245-ladsgroup.json
22:42 ladsgroup@cumin1001: END (PASS) - Cookbook sre.hosts.downtime (exit_code=0) for 1 day, 0:00:00 on db1184.eqiad.wmnet with reason: Maintenance
22:42 ladsgroup@cumin1001: START - Cookbook sre.hosts.downtime for 1 day, 0:00:00 on db1184.eqiad.wmnet with reason: Maintenance
22:42 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db1118 (T312863)', diff saved to https://phabricator.wikimedia.org/P34352 and previous config saved to /var/cache/conftool/dbconfig/20220909-224223-ladsgroup.json
22:27 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db1118', diff saved to https://phabricator.wikimedia.org/P34351 and previous config saved to /var/cache/conftool/dbconfig/20220909-222717-ladsgroup.json
22:12 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db1118', diff saved to https://phabricator.wikimedia.org/P34350 and previous config saved to /var/cache/conftool/dbconfig/20220909-221210-ladsgroup.json
21:57 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db1118 (T312863)', diff saved to https://phabricator.wikimedia.org/P34349 and previous config saved to /var/cache/conftool/dbconfig/20220909-215704-ladsgroup.json
20:27 herron@cumin1001: END (FAIL) - Cookbook sre.ganeti.makevm (exit_code=93) for new host dispatch-be1001.eqiad.wmnet
20:27 herron@cumin1001: END (PASS) - Cookbook sre.dns.wipe-cache (exit_code=0) dispatch-be1001.eqiad.wmnet on all recursors
20:27 herron@cumin1001: START - Cookbook sre.dns.wipe-cache dispatch-be1001.eqiad.wmnet on all recursors
20:27 herron@cumin1001: END (FAIL) - Cookbook sre.dns.netbox (exit_code=99)
20:18 ladsgroup@cumin1001: dbctl commit (dc=all): 'Depooling db2116 (T312863)', diff saved to https://phabricator.wikimedia.org/P34348 and previous config saved to /var/cache/conftool/dbconfig/20220909-201857-ladsgroup.json
20:18 ladsgroup@cumin1001: END (PASS) - Cookbook sre.hosts.downtime (exit_code=0) for 1 day, 0:00:00 on db2116.codfw.wmnet with reason: Maintenance
20:18 ladsgroup@cumin1001: START - Cookbook sre.hosts.downtime for 1 day, 0:00:00 on db2116.codfw.wmnet with reason: Maintenance
20:18 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db2112 (T312863)', diff saved to https://phabricator.wikimedia.org/P34347 and previous config saved to /var/cache/conftool/dbconfig/20220909-201835-ladsgroup.json
20:03 herron@cumin1001: START - Cookbook sre.ganeti.makevm for new host dispatch-be1001.eqiad.wmnet
20:03 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db2112', diff saved to https://phabricator.wikimedia.org/P34345 and previous config saved to /var/cache/conftool/dbconfig/20220909-200329-ladsgroup.json
20:02 herron@cumin1001: END (PASS) - Cookbook sre.kafka.roll-restart-brokers (exit_code=0) for Kafka A:kafka-main-eqiad cluster: Roll restart of jvm daemons.
19:48 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db2112', diff saved to https://phabricator.wikimedia.org/P34344 and previous config saved to /var/cache/conftool/dbconfig/20220909-194822-ladsgroup.json
19:33 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db2112 (T312863)', diff saved to https://phabricator.wikimedia.org/P34343 and previous config saved to /var/cache/conftool/dbconfig/20220909-193316-ladsgroup.json
18:21 herron@cumin1001: START - Cookbook sre.kafka.roll-restart-brokers for Kafka A:kafka-main-eqiad cluster: Roll restart of jvm daemons.
16:21 herron@cumin1001: END (PASS) - Cookbook sre.kafka.roll-restart-brokers (exit_code=0) for Kafka A:kafka-main-codfw cluster: Roll restart of jvm daemons.
15:52 ladsgroup@cumin1001: dbctl commit (dc=all): 'Depooling db1118 (T312863)', diff saved to https://phabricator.wikimedia.org/P34342 and previous config saved to /var/cache/conftool/dbconfig/20220909-155234-ladsgroup.json
15:52 ladsgroup@cumin1001: END (PASS) - Cookbook sre.hosts.downtime (exit_code=0) for 1 day, 0:00:00 on db1118.eqiad.wmnet with reason: Maintenance
15:52 ladsgroup@cumin1001: START - Cookbook sre.hosts.downtime for 1 day, 0:00:00 on db1118.eqiad.wmnet with reason: Maintenance
15:52 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db1106 (T312863)', diff saved to https://phabricator.wikimedia.org/P34341 and previous config saved to /var/cache/conftool/dbconfig/20220909-155213-ladsgroup.json
15:37 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db1106', diff saved to https://phabricator.wikimedia.org/P34340 and previous config saved to /var/cache/conftool/dbconfig/20220909-153706-ladsgroup.json
15:22 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db1106', diff saved to https://phabricator.wikimedia.org/P34339 and previous config saved to /var/cache/conftool/dbconfig/20220909-152159-ladsgroup.json
15:06 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db1106 (T312863)', diff saved to https://phabricator.wikimedia.org/P34338 and previous config saved to /var/cache/conftool/dbconfig/20220909-150651-ladsgroup.json
14:44 moritzm: imported jenkins 2.346.3 to thirdparty/ci
12:00 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db1157 (T312863)', diff saved to https://phabricator.wikimedia.org/P34334 and previous config saved to /var/cache/conftool/dbconfig/20220909-120029-ladsgroup.json
11:45 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db1157', diff saved to https://phabricator.wikimedia.org/P34333 and previous config saved to /var/cache/conftool/dbconfig/20220909-114522-ladsgroup.json
11:30 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db1157', diff saved to https://phabricator.wikimedia.org/P34331 and previous config saved to /var/cache/conftool/dbconfig/20220909-113016-ladsgroup.json
11:15 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db1157 (T312863)', diff saved to https://phabricator.wikimedia.org/P34330 and previous config saved to /var/cache/conftool/dbconfig/20220909-111509-ladsgroup.json
10:33 marostegui@cumin1001: dbctl commit (dc=all): 'db1137 (re)pooling @ 100%: Repooling after upgrade', diff saved to https://phabricator.wikimedia.org/P34329 and previous config saved to /var/cache/conftool/dbconfig/20220909-103334-root.json
08:37 cgoubert@cumin1001: START - Cookbook sre.hosts.decommission for hosts wtp[1029-1033].eqiad.wmnet
08:32 dcausse: rebuilding all completion indices in elastic@codfw
08:16 dcausse: restarting on blazegraph on wdqs2002 (BlazegraphFreeAllocatorsDecreasingRapidly)
08:12 elukey@deploy1002: helmfile [ml-serve-codfw] Ran 'sync' command on namespace 'revscoring-editquality-damaging' for release 'main' .
08:11 ladsgroup@cumin1001: dbctl commit (dc=all): 'Depooling db2106 (T314041)', diff saved to https://phabricator.wikimedia.org/P34322 and previous config saved to /var/cache/conftool/dbconfig/20220909-081103-ladsgroup.json
08:10 ladsgroup@cumin1001: END (PASS) - Cookbook sre.hosts.downtime (exit_code=0) for 1 day, 0:00:00 on db2106.codfw.wmnet with reason: Maintenance
08:10 ladsgroup@cumin1001: START - Cookbook sre.hosts.downtime for 1 day, 0:00:00 on db2106.codfw.wmnet with reason: Maintenance
08:10 ladsgroup@cumin1001: dbctl commit (dc=all): 'Depooling db1121 (T314041)', diff saved to https://phabricator.wikimedia.org/P34321 and previous config saved to /var/cache/conftool/dbconfig/20220909-081042-ladsgroup.json
08:10 ladsgroup@cumin1001: END (PASS) - Cookbook sre.hosts.downtime (exit_code=0) for 2 days, 0:00:00 on clouddb[1015,1019,1021].eqiad.wmnet,db1155.eqiad.wmnet with reason: Maintenance
08:10 ladsgroup@cumin1001: START - Cookbook sre.hosts.downtime for 2 days, 0:00:00 on clouddb[1015,1019,1021].eqiad.wmnet,db1155.eqiad.wmnet with reason: Maintenance
08:10 ladsgroup@cumin1001: END (PASS) - Cookbook sre.hosts.downtime (exit_code=0) for 1 day, 0:00:00 on db1121.eqiad.wmnet with reason: Maintenance
08:10 ladsgroup@cumin1001: START - Cookbook sre.hosts.downtime for 1 day, 0:00:00 on db1121.eqiad.wmnet with reason: Maintenance
08:06 ladsgroup@cumin1001: END (PASS) - Cookbook sre.hosts.downtime (exit_code=0) for 1 day, 0:00:00 on db2097.codfw.wmnet with reason: Maintenance
08:06 ladsgroup@cumin1001: START - Cookbook sre.hosts.downtime for 1 day, 0:00:00 on db2097.codfw.wmnet with reason: Maintenance
08:06 ladsgroup@cumin1001: dbctl commit (dc=all): 'Depooling db1106 (T312863)', diff saved to https://phabricator.wikimedia.org/P34320 and previous config saved to /var/cache/conftool/dbconfig/20220909-080609-ladsgroup.json
08:06 ladsgroup@cumin1001: END (PASS) - Cookbook sre.hosts.downtime (exit_code=0) for 2 days, 0:00:00 on clouddb[1013,1017,1021].eqiad.wmnet,db1154.eqiad.wmnet with reason: Maintenance
08:05 ladsgroup@cumin1001: START - Cookbook sre.hosts.downtime for 2 days, 0:00:00 on clouddb[1013,1017,1021].eqiad.wmnet,db1154.eqiad.wmnet with reason: Maintenance
08:05 ladsgroup@cumin1001: END (PASS) - Cookbook sre.hosts.downtime (exit_code=0) for 1 day, 0:00:00 on db1106.eqiad.wmnet with reason: Maintenance
08:05 ladsgroup@cumin1001: START - Cookbook sre.hosts.downtime for 1 day, 0:00:00 on db1106.eqiad.wmnet with reason: Maintenance
07:47 ladsgroup@cumin1001: dbctl commit (dc=all): 'Depooling db1157 (T312863)', diff saved to https://phabricator.wikimedia.org/P34319 and previous config saved to /var/cache/conftool/dbconfig/20220909-074710-ladsgroup.json
07:47 ladsgroup@cumin1001: END (PASS) - Cookbook sre.hosts.downtime (exit_code=0) for 1 day, 0:00:00 on db1157.eqiad.wmnet with reason: Maintenance
07:46 ladsgroup@cumin1001: START - Cookbook sre.hosts.downtime for 1 day, 0:00:00 on db1157.eqiad.wmnet with reason: Maintenance
07:46 elukey@deploy1002: helmfile [ml-serve-codfw] Ran 'sync' command on namespace 'revscoring-editquality-damaging' for release 'main' .
07:14 jmm@cumin2002: END (PASS) - Cookbook sre.hosts.reboot-single (exit_code=0) for host an-tool1007.eqiad.wmnet
07:12 marostegui@cumin1001: dbctl commit (dc=all): 'Depool db1137 for upgrade', diff saved to https://phabricator.wikimedia.org/P34318 and previous config saved to /var/cache/conftool/dbconfig/20220909-071255-root.json
07:10 jmm@cumin2002: START - Cookbook sre.hosts.reboot-single for host an-tool1007.eqiad.wmnet
05:11 ebernhardson@deploy1002: Synchronized wmf-config/InitialiseSettings.php: cirrus: Switch all wikis from completion suggester to prefix search, yesterdays completion index builds in codfw weren't all succesfull and users are getting incomplete results (duration: 04m 01s)
20:55 samtar@deploy1002: samtar and arlolra: Backport for Fix selser on html endpoints (T317215) synced to the testservers: mwdebug2001.codfw.wmnet, mwdebug1002.eqiad.wmnet, mwdebug1001.eqiad.wmnet, mwdebug2002.codfw.wmnet
20:21 samtar@deploy1002: samtar and arlolra: Backport for Fix selser on html endpoints (T317215) synced to the testservers: mwdebug2001.codfw.wmnet, mwdebug1002.eqiad.wmnet, mwdebug2002.codfw.wmnet, mwdebug1001.eqiad.wmnet
14:20 ladsgroup@cumin1001: dbctl commit (dc=all): 'db1157 (re)pooling @ 100%: Will do maint later', diff saved to https://phabricator.wikimedia.org/P34312 and previous config saved to /var/cache/conftool/dbconfig/20220908-142029-ladsgroup.json
14:16 ladsgroup@cumin1001: dbctl commit (dc=all): 'db1136 (re)pooling @ 100%: Maint over long time ago', diff saved to https://phabricator.wikimedia.org/P34311 and previous config saved to /var/cache/conftool/dbconfig/20220908-141600-ladsgroup.json
14:07 cgoubert@cumin1001: START - Cookbook sre.hosts.decommission for hosts wtp[1038-1042].eqiad.wmnet
14:06 cgoubert@cumin1001: END (PASS) - Cookbook sre.hosts.decommission (exit_code=0) for hosts wtp1037.eqiad.wmnet
14:06 cgoubert@cumin1001: END (PASS) - Cookbook sre.dns.netbox (exit_code=0)
14:05 ladsgroup@cumin1001: dbctl commit (dc=all): 'db1157 (re)pooling @ 75%: Will do maint later', diff saved to https://phabricator.wikimedia.org/P34310 and previous config saved to /var/cache/conftool/dbconfig/20220908-140524-ladsgroup.json
14:00 ladsgroup@cumin1001: dbctl commit (dc=all): 'db1136 (re)pooling @ 75%: Maint over long time ago', diff saved to https://phabricator.wikimedia.org/P34309 and previous config saved to /var/cache/conftool/dbconfig/20220908-140055-ladsgroup.json
14:00 papaul: on going maintenance on mr1-codfw
13:57 cgoubert@cumin1001: START - Cookbook sre.hosts.decommission for hosts wtp1037.eqiad.wmnet
13:55 cgoubert@cumin1001: END (PASS) - Cookbook sre.hosts.decommission (exit_code=0) for hosts wtp1036.eqiad.wmnet
13:55 cgoubert@cumin1001: END (PASS) - Cookbook sre.dns.netbox (exit_code=0)
13:51 elukey@deploy1002: helmfile [ml-serve-codfw] Ran 'sync' command on namespace 'revscoring-editquality-goodfaith' for release 'main' .
13:50 ladsgroup@cumin1001: dbctl commit (dc=all): 'db1157 (re)pooling @ 25%: Will do maint later', diff saved to https://phabricator.wikimedia.org/P34307 and previous config saved to /var/cache/conftool/dbconfig/20220908-135019-ladsgroup.json
13:47 cgoubert@cumin1001: START - Cookbook sre.hosts.decommission for hosts wtp1036.eqiad.wmnet
13:45 ladsgroup@cumin1001: dbctl commit (dc=all): 'db1136 (re)pooling @ 25%: Maint over long time ago', diff saved to https://phabricator.wikimedia.org/P34305 and previous config saved to /var/cache/conftool/dbconfig/20220908-134550-ladsgroup.json
13:43 cgoubert@cumin1001: END (PASS) - Cookbook sre.hosts.decommission (exit_code=0) for hosts wtp1035.eqiad.wmnet
13:43 cgoubert@cumin1001: END (PASS) - Cookbook sre.dns.netbox (exit_code=0)
13:43 vgutierrez: rolling upgrade to ats 9 in cp drmrs - T309651
13:39 vgutierrez: disable puppet on A:cp-drmrs during the update to ATS 9.1.3 - T309651
13:36 cgoubert@cumin1001: START - Cookbook sre.hosts.decommission for hosts wtp1035.eqiad.wmnet
13:35 ladsgroup@cumin1001: dbctl commit (dc=all): 'db1157 (re)pooling @ 10%: Will do maint later', diff saved to https://phabricator.wikimedia.org/P34304 and previous config saved to /var/cache/conftool/dbconfig/20220908-133514-ladsgroup.json
13:31 cgoubert@cumin1001: END (PASS) - Cookbook sre.hosts.decommission (exit_code=0) for hosts wtp1034.eqiad.wmnet
13:31 cgoubert@cumin1001: END (PASS) - Cookbook sre.dns.netbox (exit_code=0)
13:30 ladsgroup@cumin1001: dbctl commit (dc=all): 'db1136 (re)pooling @ 10%: Maint over long time ago', diff saved to https://phabricator.wikimedia.org/P34303 and previous config saved to /var/cache/conftool/dbconfig/20220908-133045-ladsgroup.json
13:30 marostegui@cumin1001: dbctl commit (dc=all): 'es1031 (re)pooling @ 100%: Repooling after upgrade', diff saved to https://phabricator.wikimedia.org/P34302 and previous config saved to /var/cache/conftool/dbconfig/20220908-133036-root.json
13:30 marostegui@cumin1001: dbctl commit (dc=all): 'es1030 (re)pooling @ 100%: Repooling after upgrade', diff saved to https://phabricator.wikimedia.org/P34301 and previous config saved to /var/cache/conftool/dbconfig/20220908-133031-root.json
13:30 marostegui@cumin1001: dbctl commit (dc=all): 'es1029 (re)pooling @ 100%: Repooling after upgrade', diff saved to https://phabricator.wikimedia.org/P34300 and previous config saved to /var/cache/conftool/dbconfig/20220908-133024-root.json
13:29 moritzm: installing apache2 security updates on Bullseye
12:26 cgoubert@cumin1001: END (PASS) - Cookbook sre.hosts.downtime (exit_code=0) for 7 days, 0:00:00 on wtp[1032-1033].eqiad.wmnet with reason: Downtiming replaced wtp servers
12:26 cgoubert@cumin1001: START - Cookbook sre.hosts.downtime for 7 days, 0:00:00 on wtp[1032-1033].eqiad.wmnet with reason: Downtiming replaced wtp servers
12:25 cgoubert@cumin1001: END (PASS) - Cookbook sre.hosts.downtime (exit_code=0) for 7 days, 0:00:00 on wtp[1032-1033].mgmt with reason: Downtiming replaced wtp servers
12:25 cgoubert@cumin1001: START - Cookbook sre.hosts.downtime for 7 days, 0:00:00 on wtp[1032-1033].mgmt with reason: Downtiming replaced wtp servers
12:17 elukey@deploy1002: helmfile [ml-serve-codfw] Ran 'sync' command on namespace 'revscoring-editquality-goodfaith' for release 'main' .
12:15 elukey@deploy1002: helmfile [ml-serve-codfw] Ran 'sync' command on namespace 'revscoring-editquality-damaging' for release 'main' .
12:15 marostegui@cumin1001: dbctl commit (dc=all): 'es1031 (re)pooling @ 5%: Repooling after upgrade', diff saved to https://phabricator.wikimedia.org/P34286 and previous config saved to /var/cache/conftool/dbconfig/20220908-121511-root.json
12:15 marostegui@cumin1001: dbctl commit (dc=all): 'es1030 (re)pooling @ 5%: Repooling after upgrade', diff saved to https://phabricator.wikimedia.org/P34285 and previous config saved to /var/cache/conftool/dbconfig/20220908-121506-root.json
12:14 marostegui@cumin1001: dbctl commit (dc=all): 'es1029 (re)pooling @ 5%: Repooling after upgrade', diff saved to https://phabricator.wikimedia.org/P34284 and previous config saved to /var/cache/conftool/dbconfig/20220908-121459-root.json
12:12 elukey@deploy1002: helmfile [ml-serve-codfw] Ran 'sync' command on namespace 'revscoring-editquality-reverted' for release 'main' .
12:11 elukey@deploy1002: helmfile [ml-serve-codfw] Ran 'sync' command on namespace 'revscoring-drafttopic' for release 'main' .
12:09 elukey@deploy1002: helmfile [ml-serve-codfw] Ran 'sync' command on namespace 'revscoring-draftquality' for release 'main' .
12:06 elukey@deploy1002: helmfile [ml-serve-codfw] Ran 'sync' command on namespace 'revscoring-articletopic' for release 'main' .
12:05 marostegui@cumin1001: dbctl commit (dc=all): 'Depool es1029 es1030 es1031 for upgrade', diff saved to https://phabricator.wikimedia.org/P34283 and previous config saved to /var/cache/conftool/dbconfig/20220908-120528-root.json
12:04 marostegui@cumin1001: dbctl commit (dc=all): 'es1028 (re)pooling @ 100%: Repooling after upgrade', diff saved to https://phabricator.wikimedia.org/P34282 and previous config saved to /var/cache/conftool/dbconfig/20220908-120439-root.json
12:04 marostegui@cumin1001: dbctl commit (dc=all): 'es1027 (re)pooling @ 100%: Repooling after upgrade', diff saved to https://phabricator.wikimedia.org/P34281 and previous config saved to /var/cache/conftool/dbconfig/20220908-120435-root.json
12:04 marostegui@cumin1001: dbctl commit (dc=all): 'es1026 (re)pooling @ 100%: Repooling after upgrade', diff saved to https://phabricator.wikimedia.org/P34280 and previous config saved to /var/cache/conftool/dbconfig/20220908-120427-root.json
12:03 elukey@deploy1002: helmfile [ml-serve-codfw] Ran 'sync' command on namespace 'revscoring-articlequality' for release 'main' .
11:54 marostegui@cumin1001: dbctl commit (dc=all): 'es2025 (re)pooling @ 100%: Repooling after upgrade', diff saved to https://phabricator.wikimedia.org/P34278 and previous config saved to /var/cache/conftool/dbconfig/20220908-115407-root.json
11:54 marostegui@cumin1001: dbctl commit (dc=all): 'es2022 (re)pooling @ 100%: Repooling after upgrade', diff saved to https://phabricator.wikimedia.org/P34277 and previous config saved to /var/cache/conftool/dbconfig/20220908-115401-root.json
11:53 marostegui@cumin1001: dbctl commit (dc=all): 'es1025 (re)pooling @ 100%: Repooling after upgrade', diff saved to https://phabricator.wikimedia.org/P34276 and previous config saved to /var/cache/conftool/dbconfig/20220908-115355-root.json
11:53 marostegui@cumin1001: dbctl commit (dc=all): 'es1022 (re)pooling @ 100%: Repooling after upgrade', diff saved to https://phabricator.wikimedia.org/P34275 and previous config saved to /var/cache/conftool/dbconfig/20220908-115351-root.json
11:49 marostegui@cumin1001: dbctl commit (dc=all): 'es1028 (re)pooling @ 75%: Repooling after upgrade', diff saved to https://phabricator.wikimedia.org/P34274 and previous config saved to /var/cache/conftool/dbconfig/20220908-114934-root.json
11:49 marostegui@cumin1001: dbctl commit (dc=all): 'es1027 (re)pooling @ 75%: Repooling after upgrade', diff saved to https://phabricator.wikimedia.org/P34273 and previous config saved to /var/cache/conftool/dbconfig/20220908-114930-root.json
11:49 marostegui@cumin1001: dbctl commit (dc=all): 'es1026 (re)pooling @ 75%: Repooling after upgrade', diff saved to https://phabricator.wikimedia.org/P34272 and previous config saved to /var/cache/conftool/dbconfig/20220908-114922-root.json
11:39 marostegui@cumin1001: dbctl commit (dc=all): 'es2025 (re)pooling @ 75%: Repooling after upgrade', diff saved to https://phabricator.wikimedia.org/P34271 and previous config saved to /var/cache/conftool/dbconfig/20220908-113902-root.json
11:38 marostegui@cumin1001: dbctl commit (dc=all): 'es2022 (re)pooling @ 75%: Repooling after upgrade', diff saved to https://phabricator.wikimedia.org/P34270 and previous config saved to /var/cache/conftool/dbconfig/20220908-113856-root.json
11:38 marostegui@cumin1001: dbctl commit (dc=all): 'es1025 (re)pooling @ 75%: Repooling after upgrade', diff saved to https://phabricator.wikimedia.org/P34269 and previous config saved to /var/cache/conftool/dbconfig/20220908-113850-root.json
11:38 marostegui@cumin1001: dbctl commit (dc=all): 'es1022 (re)pooling @ 75%: Repooling after upgrade', diff saved to https://phabricator.wikimedia.org/P34268 and previous config saved to /var/cache/conftool/dbconfig/20220908-113846-root.json
11:34 marostegui@cumin1001: dbctl commit (dc=all): 'es1028 (re)pooling @ 50%: Repooling after upgrade', diff saved to https://phabricator.wikimedia.org/P34267 and previous config saved to /var/cache/conftool/dbconfig/20220908-113429-root.json
11:34 marostegui@cumin1001: dbctl commit (dc=all): 'es1027 (re)pooling @ 50%: Repooling after upgrade', diff saved to https://phabricator.wikimedia.org/P34266 and previous config saved to /var/cache/conftool/dbconfig/20220908-113425-root.json
11:34 marostegui@cumin1001: dbctl commit (dc=all): 'es1026 (re)pooling @ 50%: Repooling after upgrade', diff saved to https://phabricator.wikimedia.org/P34265 and previous config saved to /var/cache/conftool/dbconfig/20220908-113417-root.json
11:23 marostegui@cumin1001: dbctl commit (dc=all): 'es2025 (re)pooling @ 50%: Repooling after upgrade', diff saved to https://phabricator.wikimedia.org/P34264 and previous config saved to /var/cache/conftool/dbconfig/20220908-112357-root.json
11:23 marostegui@cumin1001: dbctl commit (dc=all): 'es2022 (re)pooling @ 50%: Repooling after upgrade', diff saved to https://phabricator.wikimedia.org/P34263 and previous config saved to /var/cache/conftool/dbconfig/20220908-112351-root.json
11:23 marostegui@cumin1001: dbctl commit (dc=all): 'es1025 (re)pooling @ 50%: Repooling after upgrade', diff saved to https://phabricator.wikimedia.org/P34262 and previous config saved to /var/cache/conftool/dbconfig/20220908-112345-root.json
11:23 marostegui@cumin1001: dbctl commit (dc=all): 'es1022 (re)pooling @ 50%: Repooling after upgrade', diff saved to https://phabricator.wikimedia.org/P34261 and previous config saved to /var/cache/conftool/dbconfig/20220908-112341-root.json
11:23 marostegui@cumin1001: dbctl commit (dc=all): 'es2034 (re)pooling @ 100%: Repooling after upgrade', diff saved to https://phabricator.wikimedia.org/P34260 and previous config saved to /var/cache/conftool/dbconfig/20220908-112329-root.json
11:23 marostegui@cumin1001: dbctl commit (dc=all): 'es2033 (re)pooling @ 100%: Repooling after upgrade', diff saved to https://phabricator.wikimedia.org/P34259 and previous config saved to /var/cache/conftool/dbconfig/20220908-112324-root.json
11:23 marostegui@cumin1001: dbctl commit (dc=all): 'es2032 (re)pooling @ 100%: Repooling after upgrade', diff saved to https://phabricator.wikimedia.org/P34258 and previous config saved to /var/cache/conftool/dbconfig/20220908-112319-root.json
11:19 marostegui@cumin1001: dbctl commit (dc=all): 'es1028 (re)pooling @ 25%: Repooling after upgrade', diff saved to https://phabricator.wikimedia.org/P34257 and previous config saved to /var/cache/conftool/dbconfig/20220908-111924-root.json
11:19 marostegui@cumin1001: dbctl commit (dc=all): 'es1027 (re)pooling @ 25%: Repooling after upgrade', diff saved to https://phabricator.wikimedia.org/P34256 and previous config saved to /var/cache/conftool/dbconfig/20220908-111920-root.json
11:19 marostegui@cumin1001: dbctl commit (dc=all): 'es1026 (re)pooling @ 25%: Repooling after upgrade', diff saved to https://phabricator.wikimedia.org/P34255 and previous config saved to /var/cache/conftool/dbconfig/20220908-111912-root.json
11:08 marostegui@cumin1001: dbctl commit (dc=all): 'es2025 (re)pooling @ 25%: Repooling after upgrade', diff saved to https://phabricator.wikimedia.org/P34254 and previous config saved to /var/cache/conftool/dbconfig/20220908-110852-root.json
11:08 marostegui@cumin1001: dbctl commit (dc=all): 'es2022 (re)pooling @ 25%: Repooling after upgrade', diff saved to https://phabricator.wikimedia.org/P34253 and previous config saved to /var/cache/conftool/dbconfig/20220908-110846-root.json
11:08 marostegui@cumin1001: dbctl commit (dc=all): 'es1025 (re)pooling @ 25%: Repooling after upgrade', diff saved to https://phabricator.wikimedia.org/P34252 and previous config saved to /var/cache/conftool/dbconfig/20220908-110840-root.json
11:08 marostegui@cumin1001: dbctl commit (dc=all): 'es1022 (re)pooling @ 25%: Repooling after upgrade', diff saved to https://phabricator.wikimedia.org/P34251 and previous config saved to /var/cache/conftool/dbconfig/20220908-110836-root.json
11:08 marostegui@cumin1001: dbctl commit (dc=all): 'es2034 (re)pooling @ 75%: Repooling after upgrade', diff saved to https://phabricator.wikimedia.org/P34250 and previous config saved to /var/cache/conftool/dbconfig/20220908-110825-root.json
11:08 marostegui@cumin1001: dbctl commit (dc=all): 'es2033 (re)pooling @ 75%: Repooling after upgrade', diff saved to https://phabricator.wikimedia.org/P34249 and previous config saved to /var/cache/conftool/dbconfig/20220908-110819-root.json
11:08 marostegui@cumin1001: dbctl commit (dc=all): 'es2032 (re)pooling @ 75%: Repooling after upgrade', diff saved to https://phabricator.wikimedia.org/P34248 and previous config saved to /var/cache/conftool/dbconfig/20220908-110814-root.json
11:04 marostegui@cumin1001: dbctl commit (dc=all): 'es1028 (re)pooling @ 10%: Repooling after upgrade', diff saved to https://phabricator.wikimedia.org/P34247 and previous config saved to /var/cache/conftool/dbconfig/20220908-110419-root.json
11:04 marostegui@cumin1001: dbctl commit (dc=all): 'es1027 (re)pooling @ 10%: Repooling after upgrade', diff saved to https://phabricator.wikimedia.org/P34246 and previous config saved to /var/cache/conftool/dbconfig/20220908-110415-root.json
11:04 marostegui@cumin1001: dbctl commit (dc=all): 'es1026 (re)pooling @ 10%: Repooling after upgrade', diff saved to https://phabricator.wikimedia.org/P34245 and previous config saved to /var/cache/conftool/dbconfig/20220908-110407-root.json
10:53 marostegui@cumin1001: dbctl commit (dc=all): 'es2025 (re)pooling @ 10%: Repooling after upgrade', diff saved to https://phabricator.wikimedia.org/P34244 and previous config saved to /var/cache/conftool/dbconfig/20220908-105347-root.json
10:53 marostegui@cumin1001: dbctl commit (dc=all): 'es2022 (re)pooling @ 10%: Repooling after upgrade', diff saved to https://phabricator.wikimedia.org/P34243 and previous config saved to /var/cache/conftool/dbconfig/20220908-105341-root.json
10:53 marostegui@cumin1001: dbctl commit (dc=all): 'es1025 (re)pooling @ 10%: Repooling after upgrade', diff saved to https://phabricator.wikimedia.org/P34242 and previous config saved to /var/cache/conftool/dbconfig/20220908-105335-root.json
10:53 marostegui@cumin1001: dbctl commit (dc=all): 'es1022 (re)pooling @ 10%: Repooling after upgrade', diff saved to https://phabricator.wikimedia.org/P34241 and previous config saved to /var/cache/conftool/dbconfig/20220908-105331-root.json
10:53 marostegui@cumin1001: dbctl commit (dc=all): 'es2034 (re)pooling @ 50%: Repooling after upgrade', diff saved to https://phabricator.wikimedia.org/P34240 and previous config saved to /var/cache/conftool/dbconfig/20220908-105320-root.json
10:53 marostegui@cumin1001: dbctl commit (dc=all): 'es2033 (re)pooling @ 50%: Repooling after upgrade', diff saved to https://phabricator.wikimedia.org/P34239 and previous config saved to /var/cache/conftool/dbconfig/20220908-105314-root.json
10:53 marostegui@cumin1001: dbctl commit (dc=all): 'es2032 (re)pooling @ 50%: Repooling after upgrade', diff saved to https://phabricator.wikimedia.org/P34238 and previous config saved to /var/cache/conftool/dbconfig/20220908-105309-root.json
10:49 marostegui@cumin1001: dbctl commit (dc=all): 'es1028 (re)pooling @ 5%: Repooling after upgrade', diff saved to https://phabricator.wikimedia.org/P34237 and previous config saved to /var/cache/conftool/dbconfig/20220908-104914-root.json
10:49 marostegui@cumin1001: dbctl commit (dc=all): 'es1027 (re)pooling @ 5%: Repooling after upgrade', diff saved to https://phabricator.wikimedia.org/P34236 and previous config saved to /var/cache/conftool/dbconfig/20220908-104910-root.json
10:49 marostegui@cumin1001: dbctl commit (dc=all): 'es1026 (re)pooling @ 5%: Repooling after upgrade', diff saved to https://phabricator.wikimedia.org/P34235 and previous config saved to /var/cache/conftool/dbconfig/20220908-104902-root.json
10:41 marostegui@cumin1001: dbctl commit (dc=all): 'Depool es1027 es1026 es1028 for upgrade', diff saved to https://phabricator.wikimedia.org/P34234 and previous config saved to /var/cache/conftool/dbconfig/20220908-104152-root.json
10:38 marostegui@cumin1001: dbctl commit (dc=all): 'es2025 (re)pooling @ 5%: Repooling after upgrade', diff saved to https://phabricator.wikimedia.org/P34233 and previous config saved to /var/cache/conftool/dbconfig/20220908-103842-root.json
10:38 marostegui@cumin1001: dbctl commit (dc=all): 'es2022 (re)pooling @ 5%: Repooling after upgrade', diff saved to https://phabricator.wikimedia.org/P34232 and previous config saved to /var/cache/conftool/dbconfig/20220908-103836-root.json
10:38 marostegui@cumin1001: dbctl commit (dc=all): 'es1025 (re)pooling @ 5%: Repooling after upgrade', diff saved to https://phabricator.wikimedia.org/P34231 and previous config saved to /var/cache/conftool/dbconfig/20220908-103830-root.json
10:38 marostegui@cumin1001: dbctl commit (dc=all): 'es1022 (re)pooling @ 5%: Repooling after upgrade', diff saved to https://phabricator.wikimedia.org/P34230 and previous config saved to /var/cache/conftool/dbconfig/20220908-103826-root.json
10:38 marostegui@cumin1001: dbctl commit (dc=all): 'es2034 (re)pooling @ 25%: Repooling after upgrade', diff saved to https://phabricator.wikimedia.org/P34229 and previous config saved to /var/cache/conftool/dbconfig/20220908-103815-root.json
10:38 marostegui@cumin1001: dbctl commit (dc=all): 'es2033 (re)pooling @ 25%: Repooling after upgrade', diff saved to https://phabricator.wikimedia.org/P34228 and previous config saved to /var/cache/conftool/dbconfig/20220908-103809-root.json
10:38 marostegui@cumin1001: dbctl commit (dc=all): 'es2032 (re)pooling @ 25%: Repooling after upgrade', diff saved to https://phabricator.wikimedia.org/P34227 and previous config saved to /var/cache/conftool/dbconfig/20220908-103804-root.json
10:06 cgoubert@cumin1001: END (PASS) - Cookbook sre.hosts.downtime (exit_code=0) for 7 days, 0:00:00 on wtp[1029-1031].eqiad.wmnet with reason: Downtiming replaced wtp servers
10:05 cgoubert@cumin1001: START - Cookbook sre.hosts.downtime for 7 days, 0:00:00 on wtp[1029-1031].eqiad.wmnet with reason: Downtiming replaced wtp servers
10:01 marostegui@cumin1001: END (PASS) - Cookbook sre.hosts.downtime (exit_code=0) for 1:00:00 on es[2032-2034].codfw.wmnet with reason: Upgrade
10:01 marostegui@cumin1001: START - Cookbook sre.hosts.downtime for 1:00:00 on es[2032-2034].codfw.wmnet with reason: Upgrade
10:01 claime: Serving 100% of parsoid traffic with php 7.4 T307219
10:00 claime: depooled wtp1033.eqiad.wmnet from parsoid cluster T307219
10:00 marostegui@cumin1001: dbctl commit (dc=all): 'es2029 (re)pooling @ 100%: Repooling after upgrade', diff saved to https://phabricator.wikimedia.org/P34217 and previous config saved to /var/cache/conftool/dbconfig/20220908-100028-root.json
10:00 marostegui@cumin1001: dbctl commit (dc=all): 'es2030 (re)pooling @ 100%: Repooling after upgrade', diff saved to https://phabricator.wikimedia.org/P34216 and previous config saved to /var/cache/conftool/dbconfig/20220908-100027-root.json
10:00 marostegui@cumin1001: dbctl commit (dc=all): 'es2031 (re)pooling @ 100%: Repooling after upgrade', diff saved to https://phabricator.wikimedia.org/P34215 and previous config saved to /var/cache/conftool/dbconfig/20220908-100025-root.json
10:00 marostegui@cumin1001: dbctl commit (dc=all): 'Depool es2032 es2033 es2034 for upgrade', diff saved to https://phabricator.wikimedia.org/P34214 and previous config saved to /var/cache/conftool/dbconfig/20220908-100014-root.json
09:58 marostegui@cumin2002: dbctl commit (dc=all): 'db1127 (re)pooling @ 50%: Repooling after upgrade', diff saved to https://phabricator.wikimedia.org/P34213 and previous config saved to /var/cache/conftool/dbconfig/20220908-095759-root.json
09:50 claime: pooled parse1024.eqiad.wmnet (php 7.4 only) in parsoid cluster T307219
09:50 cgoubert@cumin1001: END (PASS) - Cookbook sre.hosts.remove-downtime (exit_code=0) for parse1024.eqiad.wmnet
09:50 cgoubert@cumin1001: START - Cookbook sre.hosts.remove-downtime for parse1024.eqiad.wmnet
09:47 claime: depooled wtp1032.eqiad.wmnet from parsoid cluster T307219
09:45 marostegui@cumin1001: dbctl commit (dc=all): 'es2029 (re)pooling @ 75%: Repooling after upgrade', diff saved to https://phabricator.wikimedia.org/P34212 and previous config saved to /var/cache/conftool/dbconfig/20220908-094523-root.json
09:45 marostegui@cumin1001: dbctl commit (dc=all): 'es2030 (re)pooling @ 75%: Repooling after upgrade', diff saved to https://phabricator.wikimedia.org/P34211 and previous config saved to /var/cache/conftool/dbconfig/20220908-094522-root.json
09:45 marostegui@cumin1001: dbctl commit (dc=all): 'es2031 (re)pooling @ 75%: Repooling after upgrade', diff saved to https://phabricator.wikimedia.org/P34210 and previous config saved to /var/cache/conftool/dbconfig/20220908-094520-root.json
09:42 marostegui@cumin2002: dbctl commit (dc=all): 'db1127 (re)pooling @ 25%: Repooling after upgrade', diff saved to https://phabricator.wikimedia.org/P34209 and previous config saved to /var/cache/conftool/dbconfig/20220908-094229-root.json
09:16 cgoubert@cumin1001: END (PASS) - Cookbook sre.hosts.downtime (exit_code=0) for 7 days, 0:00:00 on wtp[1025-1028].eqiad.wmnet with reason: Downtiming replaced wtp servers
08:53 claime: depooled wtp1029.eqiad.wmnet from parsoid cluster T307219
08:51 jmm@cumin2002: END (PASS) - Cookbook sre.hosts.reboot-single (exit_code=0) for host an-tool1011.eqiad.wmnet
08:47 jmm@cumin2002: START - Cookbook sre.hosts.reboot-single for host an-tool1011.eqiad.wmnet
08:45 ayounsi@cumin2002: END (PASS) - Cookbook sre.hosts.downtime (exit_code=0) for 2:00:00 on cr2-esams,cr2-esams IPv6,re0.cr2-esams.mgmt with reason: router upgrade
08:45 marostegui@cumin1001: dbctl commit (dc=all): 'es2029 (re)pooling @ 5%: Repooling after upgrade', diff saved to https://phabricator.wikimedia.org/P34186 and previous config saved to /var/cache/conftool/dbconfig/20220908-084503-root.json
08:45 marostegui@cumin1001: dbctl commit (dc=all): 'es2030 (re)pooling @ 5%: Repooling after upgrade', diff saved to https://phabricator.wikimedia.org/P34185 and previous config saved to /var/cache/conftool/dbconfig/20220908-084502-root.json
08:45 marostegui@cumin1001: dbctl commit (dc=all): 'es2031 (re)pooling @ 5%: Repooling after upgrade', diff saved to https://phabricator.wikimedia.org/P34184 and previous config saved to /var/cache/conftool/dbconfig/20220908-084500-root.json
08:44 ayounsi@cumin2002: START - Cookbook sre.hosts.downtime for 2:00:00 on cr2-esams,cr2-esams IPv6,re0.cr2-esams.mgmt with reason: router upgrade
08:44 XioNoX: reverting cr3-esams changes (JTAC will be needed for a firmware upgrade), and moving on to cr2-esams - T295690
08:41 marostegui@cumin2002: dbctl commit (dc=all): 'db1203 (re)pooling @ 100%: Pooling for the first time in s8', diff saved to https://phabricator.wikimedia.org/P34183 and previous config saved to /var/cache/conftool/dbconfig/20220908-084133-root.json
08:41 claime: pooled parse1020.eqiad.wmnet (php 7.4 only) in parsoid cluster T307219
08:41 marostegui@cumin2002: dbctl commit (dc=all): 'es2026 (re)pooling @ 50%: Repooling after upgrade', diff saved to https://phabricator.wikimedia.org/P34182 and previous config saved to /var/cache/conftool/dbconfig/20220908-084059-root.json
08:40 marostegui@cumin2002: dbctl commit (dc=all): 'es2028 (re)pooling @ 50%: Repooling after upgrade', diff saved to https://phabricator.wikimedia.org/P34181 and previous config saved to /var/cache/conftool/dbconfig/20220908-084057-root.json
08:40 marostegui@cumin2002: dbctl commit (dc=all): 'es2027 (re)pooling @ 50%: Repooling after upgrade', diff saved to https://phabricator.wikimedia.org/P34180 and previous config saved to /var/cache/conftool/dbconfig/20220908-084051-root.json
08:40 cgoubert@cumin2002: END (PASS) - Cookbook sre.hosts.remove-downtime (exit_code=0) for parse1020.eqiad.wmnet
08:40 cgoubert@cumin2002: START - Cookbook sre.hosts.remove-downtime for parse1020.eqiad.wmnet
08:40 marostegui@cumin2002: dbctl commit (dc=all): 'db1127 (re)pooling @ 3%: Repooling after upgrade', diff saved to https://phabricator.wikimedia.org/P34179 and previous config saved to /var/cache/conftool/dbconfig/20220908-084029-root.json
08:40 claime: depooled wtp1028.eqiad.wmnet from parsoid cluster T307219
08:39 marostegui@cumin2002: dbctl commit (dc=all): 'Depool es2029, es2030, es2031', diff saved to https://phabricator.wikimedia.org/P34178 and previous config saved to /var/cache/conftool/dbconfig/20220908-083941-marostegui.json
08:26 marostegui@cumin2002: dbctl commit (dc=all): 'db1203 (re)pooling @ 75%: Pooling for the first time in s8', diff saved to https://phabricator.wikimedia.org/P34176 and previous config saved to /var/cache/conftool/dbconfig/20220908-082604-root.json
08:25 marostegui@cumin2002: dbctl commit (dc=all): 'es2026 (re)pooling @ 25%: Repooling after upgrade', diff saved to https://phabricator.wikimedia.org/P34175 and previous config saved to /var/cache/conftool/dbconfig/20220908-082530-root.json
08:25 marostegui@cumin2002: dbctl commit (dc=all): 'es2028 (re)pooling @ 25%: Repooling after upgrade', diff saved to https://phabricator.wikimedia.org/P34174 and previous config saved to /var/cache/conftool/dbconfig/20220908-082528-root.json
08:25 marostegui@cumin2002: dbctl commit (dc=all): 'es2027 (re)pooling @ 25%: Repooling after upgrade', diff saved to https://phabricator.wikimedia.org/P34173 and previous config saved to /var/cache/conftool/dbconfig/20220908-082521-root.json
08:25 marostegui@cumin2002: dbctl commit (dc=all): 'db1127 (re)pooling @ 2%: Repooling after upgrade', diff saved to https://phabricator.wikimedia.org/P34172 and previous config saved to /var/cache/conftool/dbconfig/20220908-082500-root.json
08:24 claime: pooled parse1019.eqiad.wmnet (php 7.4 only) in parsoid cluster T307219
08:22 cgoubert@cumin2002: END (PASS) - Cookbook sre.hosts.remove-downtime (exit_code=0) for parse1019.eqiad.wmnet
08:22 cgoubert@cumin2002: START - Cookbook sre.hosts.remove-downtime for parse1019.eqiad.wmnet
08:12 jmm@cumin2002: END (FAIL) - Cookbook sre.hosts.reboot-single (exit_code=1) for host cumin1001.eqiad.wmnet
08:10 ayounsi@cumin2002: END (PASS) - Cookbook sre.network.cf (exit_code=0)
08:10 marostegui@cumin2002: dbctl commit (dc=all): 'db1203 (re)pooling @ 50%: Pooling for the first time in s8', diff saved to https://phabricator.wikimedia.org/P34171 and previous config saved to /var/cache/conftool/dbconfig/20220908-081034-root.json
08:09 marostegui@cumin2002: dbctl commit (dc=all): 'es2028 (re)pooling @ 10%: Repooling after upgrade', diff saved to https://phabricator.wikimedia.org/P34170 and previous config saved to /var/cache/conftool/dbconfig/20220908-080958-root.json
08:09 marostegui@cumin2002: dbctl commit (dc=all): 'es2027 (re)pooling @ 10%: Repooling after upgrade', diff saved to https://phabricator.wikimedia.org/P34169 and previous config saved to /var/cache/conftool/dbconfig/20220908-080951-root.json
08:09 marostegui@cumin2002: dbctl commit (dc=all): 'es2026 (re)pooling @ 10%: Repooling after upgrade', diff saved to https://phabricator.wikimedia.org/P34168 and previous config saved to /var/cache/conftool/dbconfig/20220908-080946-root.json
08:09 ayounsi@cumin2002: END (PASS) - Cookbook sre.hosts.downtime (exit_code=0) for 2:00:00 on cr3-esams,cr3-esams IPv6,re0.cr3-esams.mgmt with reason: router upgrade
08:09 ayounsi@cumin2002: START - Cookbook sre.hosts.downtime for 2:00:00 on cr3-esams,cr3-esams IPv6,re0.cr3-esams.mgmt with reason: router upgrade
08:08 marostegui@cumin2002: dbctl commit (dc=all): 'db1202 (re)pooling @ 100%: Pooling for the first time in s7', diff saved to https://phabricator.wikimedia.org/P34167 and previous config saved to /var/cache/conftool/dbconfig/20220908-080823-root.json
08:07 XioNoX: drain draffic from cr3-esams - T295690
08:00 jmm@cumin2002: START - Cookbook sre.hosts.reboot-single for host cumin1001.eqiad.wmnet
07:55 marostegui@cumin2002: dbctl commit (dc=all): 'db1203 (re)pooling @ 25%: Pooling for the first time in s8', diff saved to https://phabricator.wikimedia.org/P34166 and previous config saved to /var/cache/conftool/dbconfig/20220908-075504-root.json
07:54 marostegui@cumin2002: dbctl commit (dc=all): 'es2028 (re)pooling @ 5%: Repooling after upgrade', diff saved to https://phabricator.wikimedia.org/P34165 and previous config saved to /var/cache/conftool/dbconfig/20220908-075429-root.json
07:54 marostegui@cumin2002: dbctl commit (dc=all): 'es2027 (re)pooling @ 5%: Repooling after upgrade', diff saved to https://phabricator.wikimedia.org/P34164 and previous config saved to /var/cache/conftool/dbconfig/20220908-075421-root.json
07:54 marostegui@cumin2002: dbctl commit (dc=all): 'es2026 (re)pooling @ 5%: Repooling after upgrade', diff saved to https://phabricator.wikimedia.org/P34163 and previous config saved to /var/cache/conftool/dbconfig/20220908-075416-root.json
07:52 marostegui@cumin2002: dbctl commit (dc=all): 'db1202 (re)pooling @ 75%: Pooling for the first time in s7', diff saved to https://phabricator.wikimedia.org/P34162 and previous config saved to /var/cache/conftool/dbconfig/20220908-075253-root.json
07:41 XioNoX: depool esams for routers upgrade - T295690
07:39 marostegui@cumin2002: dbctl commit (dc=all): 'db1203 (re)pooling @ 10%: Pooling for the first time in s8', diff saved to https://phabricator.wikimedia.org/P34161 and previous config saved to /var/cache/conftool/dbconfig/20220908-073935-root.json
07:39 marostegui@cumin2002: dbctl commit (dc=all): 'es2028 (re)pooling @ 4%: Repooling after upgrade', diff saved to https://phabricator.wikimedia.org/P34160 and previous config saved to /var/cache/conftool/dbconfig/20220908-073900-root.json
07:38 marostegui@cumin2002: dbctl commit (dc=all): 'es2027 (re)pooling @ 4%: Repooling after upgrade', diff saved to https://phabricator.wikimedia.org/P34159 and previous config saved to /var/cache/conftool/dbconfig/20220908-073851-root.json
07:38 marostegui@cumin2002: dbctl commit (dc=all): 'es2026 (re)pooling @ 4%: Repooling after upgrade', diff saved to https://phabricator.wikimedia.org/P34158 and previous config saved to /var/cache/conftool/dbconfig/20220908-073846-root.json
07:37 marostegui@cumin2002: dbctl commit (dc=all): 'db1202 (re)pooling @ 50%: Pooling for the first time in s7', diff saved to https://phabricator.wikimedia.org/P34157 and previous config saved to /var/cache/conftool/dbconfig/20220908-073724-root.json
07:24 marostegui@cumin2002: dbctl commit (dc=all): 'db1203 (re)pooling @ 5%: Pooling for the first time in s8', diff saved to https://phabricator.wikimedia.org/P34156 and previous config saved to /var/cache/conftool/dbconfig/20220908-072405-root.json
07:23 marostegui@cumin2002: dbctl commit (dc=all): 'es2028 (re)pooling @ 3%: Repooling after upgrade', diff saved to https://phabricator.wikimedia.org/P34155 and previous config saved to /var/cache/conftool/dbconfig/20220908-072330-root.json
07:23 marostegui@cumin2002: dbctl commit (dc=all): 'es2027 (re)pooling @ 3%: Repooling after upgrade', diff saved to https://phabricator.wikimedia.org/P34154 and previous config saved to /var/cache/conftool/dbconfig/20220908-072321-root.json
07:23 marostegui@cumin2002: dbctl commit (dc=all): 'es2026 (re)pooling @ 3%: Repooling after upgrade', diff saved to https://phabricator.wikimedia.org/P34153 and previous config saved to /var/cache/conftool/dbconfig/20220908-072316-root.json
07:21 marostegui@cumin2002: dbctl commit (dc=all): 'db1202 (re)pooling @ 25%: Pooling for the first time in s7', diff saved to https://phabricator.wikimedia.org/P34152 and previous config saved to /var/cache/conftool/dbconfig/20220908-072154-root.json
07:08 marostegui@cumin2002: dbctl commit (dc=all): 'db1203 (re)pooling @ 4%: Pooling for the first time in s8', diff saved to https://phabricator.wikimedia.org/P34151 and previous config saved to /var/cache/conftool/dbconfig/20220908-070836-root.json
07:08 marostegui@cumin2002: dbctl commit (dc=all): 'es2028 (re)pooling @ 2%: Repooling after upgrade', diff saved to https://phabricator.wikimedia.org/P34150 and previous config saved to /var/cache/conftool/dbconfig/20220908-070800-root.json
07:07 marostegui@cumin2002: dbctl commit (dc=all): 'es2027 (re)pooling @ 2%: Repooling after upgrade', diff saved to https://phabricator.wikimedia.org/P34149 and previous config saved to /var/cache/conftool/dbconfig/20220908-070752-root.json
07:07 marostegui@cumin2002: dbctl commit (dc=all): 'es2026 (re)pooling @ 2%: Repooling after upgrade', diff saved to https://phabricator.wikimedia.org/P34148 and previous config saved to /var/cache/conftool/dbconfig/20220908-070746-root.json
07:06 marostegui@cumin2002: dbctl commit (dc=all): 'db1202 (re)pooling @ 10%: Pooling for the first time in s7', diff saved to https://phabricator.wikimedia.org/P34147 and previous config saved to /var/cache/conftool/dbconfig/20220908-070625-root.json
06:53 marostegui@cumin2002: dbctl commit (dc=all): 'db1203 (re)pooling @ 3%: Pooling for the first time in s8', diff saved to https://phabricator.wikimedia.org/P34146 and previous config saved to /var/cache/conftool/dbconfig/20220908-065306-root.json
06:52 marostegui@cumin2002: dbctl commit (dc=all): 'es2028 (re)pooling @ 1%: Repooling after upgrade', diff saved to https://phabricator.wikimedia.org/P34145 and previous config saved to /var/cache/conftool/dbconfig/20220908-065229-root.json
06:52 marostegui@cumin2002: dbctl commit (dc=all): 'es2027 (re)pooling @ 1%: Repooling after upgrade', diff saved to https://phabricator.wikimedia.org/P34144 and previous config saved to /var/cache/conftool/dbconfig/20220908-065222-root.json
06:52 marostegui@cumin2002: dbctl commit (dc=all): 'es2026 (re)pooling @ 1%: Repooling after upgrade', diff saved to https://phabricator.wikimedia.org/P34143 and previous config saved to /var/cache/conftool/dbconfig/20220908-065216-root.json
06:50 marostegui@cumin2002: dbctl commit (dc=all): 'db1202 (re)pooling @ 5%: Pooling for the first time in s7', diff saved to https://phabricator.wikimedia.org/P34142 and previous config saved to /var/cache/conftool/dbconfig/20220908-065054-root.json
06:44 marostegui@cumin2002: dbctl commit (dc=all): 'Depool es2026, es2027, es2028', diff saved to https://phabricator.wikimedia.org/P34141 and previous config saved to /var/cache/conftool/dbconfig/20220908-064450-marostegui.json
06:37 marostegui@cumin2002: dbctl commit (dc=all): 'db1203 (re)pooling @ 2%: Pooling for the first time in s8', diff saved to https://phabricator.wikimedia.org/P34140 and previous config saved to /var/cache/conftool/dbconfig/20220908-063737-root.json
06:35 marostegui@cumin2002: dbctl commit (dc=all): 'db1202 (re)pooling @ 4%: Pooling for the first time in s7', diff saved to https://phabricator.wikimedia.org/P34139 and previous config saved to /var/cache/conftool/dbconfig/20220908-063525-root.json
06:19 marostegui@cumin2002: dbctl commit (dc=all): 'db1202 (re)pooling @ 3%: Pooling for the first time in s7', diff saved to https://phabricator.wikimedia.org/P34138 and previous config saved to /var/cache/conftool/dbconfig/20220908-061955-root.json
06:14 marostegui@cumin2002: dbctl commit (dc=all): 'Add db1203 to s8, depooled, T316342', diff saved to https://phabricator.wikimedia.org/P34137 and previous config saved to /var/cache/conftool/dbconfig/20220908-061413-marostegui.json
06:09 ladsgroup@cumin1001: END (PASS) - Cookbook sre.hosts.downtime (exit_code=0) for 1 day, 0:00:00 on db1157.eqiad.wmnet with reason: Maintenance
06:09 ladsgroup@cumin1001: START - Cookbook sre.hosts.downtime for 1 day, 0:00:00 on db1157.eqiad.wmnet with reason: Maintenance
06:04 ladsgroup@cumin1001: dbctl commit (dc=all): 'Depool db1157 T316622', diff saved to https://phabricator.wikimedia.org/P34136 and previous config saved to /var/cache/conftool/dbconfig/20220908-060438-ladsgroup.json
06:04 marostegui@cumin2002: dbctl commit (dc=all): 'db1202 (re)pooling @ 2%: Pooling for the first time in s7', diff saved to https://phabricator.wikimedia.org/P34135 and previous config saved to /var/cache/conftool/dbconfig/20220908-060426-root.json
06:01 ladsgroup@cumin1001: dbctl commit (dc=all): 'Promote db1123 to s3 primary and set section read-write T316622', diff saved to https://phabricator.wikimedia.org/P34134 and previous config saved to /var/cache/conftool/dbconfig/20220908-060138-ladsgroup.json
06:01 ladsgroup@cumin1001: dbctl commit (dc=all): 'Set s3 eqiad as read-only for maintenance - T316622', diff saved to https://phabricator.wikimedia.org/P34133 and previous config saved to /var/cache/conftool/dbconfig/20220908-060110-ladsgroup.json
06:00 Amir1: Starting s3 eqiad failover from db1157 to db1123 - T316622
05:55 marostegui@cumin1001: dbctl commit (dc=all): 'Increase weight for db1194', diff saved to https://phabricator.wikimedia.org/P34132 and previous config saved to /var/cache/conftool/dbconfig/20220908-055546-marostegui.json
05:54 marostegui@cumin1001: dbctl commit (dc=all): 'Pooling db1202 for the first time in s7 T316342', diff saved to https://phabricator.wikimedia.org/P34131 and previous config saved to /var/cache/conftool/dbconfig/20220908-055451-marostegui.json
05:49 ladsgroup@cumin1001: dbctl commit (dc=all): 'Pooling back db2140', diff saved to https://phabricator.wikimedia.org/P34130 and previous config saved to /var/cache/conftool/dbconfig/20220908-054921-ladsgroup.json
05:44 marostegui@cumin1001: dbctl commit (dc=all): 'Add db1202 to s7, depooled, T316342', diff saved to https://phabricator.wikimedia.org/P34129 and previous config saved to /var/cache/conftool/dbconfig/20220908-054429-marostegui.json
05:10 ladsgroup@cumin1001: dbctl commit (dc=all): 'Set db1123 with weight 0 T316622', diff saved to https://phabricator.wikimedia.org/P34128 and previous config saved to /var/cache/conftool/dbconfig/20220908-051043-ladsgroup.json
05:10 ladsgroup@cumin1001: END (PASS) - Cookbook sre.hosts.downtime (exit_code=0) for 1:00:00 on 23 hosts with reason: Primary switchover s3 T316622
05:09 ladsgroup@cumin1001: START - Cookbook sre.hosts.downtime for 1:00:00 on 23 hosts with reason: Primary switchover s3 T316622
02:04 pt1979@cumin1001: END (PASS) - Cookbook sre.network.configure-switch-interfaces (exit_code=0) for host kafka-logging1005:
02:04 pt1979@cumin1001: START - Cookbook sre.network.configure-switch-interfaces for host kafka-logging1005:
02:02 pt1979@cumin1001: END (ERROR) - Cookbook sre.network.configure-switch-interfaces (exit_code=97) for host db2169
02:02 pt1979@cumin1001: START - Cookbook sre.network.configure-switch-interfaces for host db2169
02:01 pt1979@cumin1001: END (PASS) - Cookbook sre.dns.netbox (exit_code=0)
21:19 samtar@deploy1002: samtar and jdlrobson: Backport for Respect skin's TOC option (T316947) synced to the testservers: mwdebug1001.eqiad.wmnet, mwdebug2002.codfw.wmnet, mwdebug1002.eqiad.wmnet, mwdebug2001.codfw.wmnet
21:07 samtar@deploy1002: samtar and jdlrobson: Backport for Respect skin's TOC option (T316947) synced to the testservers: mwdebug1002.eqiad.wmnet, mwdebug2002.codfw.wmnet, mwdebug1001.eqiad.wmnet, mwdebug2001.codfw.wmnet
20:51 samtar@deploy1002: samtar and jdlrobson: Backport for Enable Extension:Nearby on wikidata (T246493) synced to the testservers: mwdebug2001.codfw.wmnet, mwdebug1001.eqiad.wmnet, mwdebug1002.eqiad.wmnet, mwdebug2002.codfw.wmnet
20:12 mutante: pcc-worker1003 - rm of /srv/jenkins/puppet-compiler/output/36713 and 37153 - /srv is back to 58% usage again
20:10 mutante: integration.wikimedia.org - clicked to delete builds 36713 and 37153 because they were several GB in size
20:08 TheresNoTime: running `extensions/WikimediaMaintenance/createExtensionTables.php discussiontools` on mwmaint1002
20:08 mutante: puppet compiler out of disk space, (pcc-worker1003): identified build 37153 as huge compared to others in the filesystem, then clicked to delete it via integration.wm.org web UI
19:26 herron@cumin1001: END (PASS) - Cookbook sre.kafka.roll-restart-brokers (exit_code=0) for Kafka A:kafka-logging-eqiad cluster: Roll restart of jvm daemons.
18:33 dduvall@deploy1002: Started deploy [phabricator/deployment@a7616e6]: testing deployment to phab2001 (inactive)
18:26 herron@cumin1001: START - Cookbook sre.kafka.roll-restart-brokers for Kafka A:kafka-logging-eqiad cluster: Roll restart of jvm daemons.
18:25 herron@cumin1001: END (PASS) - Cookbook sre.kafka.roll-restart-brokers (exit_code=0) for Kafka A:kafka-logging-codfw cluster: Roll restart of jvm daemons.
17:24 herron@cumin1001: START - Cookbook sre.kafka.roll-restart-brokers for Kafka A:kafka-logging-codfw cluster: Roll restart of jvm daemons.
16:56 ejegg: restarted fundraising scheduled jobs
16:34 ejegg: fundraising civicrm upgraded from 2fcd3bb4 to c1f0e041
15:10 cgoubert@cumin1001: END (PASS) - Cookbook sre.hosts.downtime (exit_code=0) for 7 days, 0:00:00 on wtp[1027,1047-1048].eqiad.wmnet with reason: Downtiming replaced wtp servers
15:10 cgoubert@cumin1001: START - Cookbook sre.hosts.downtime for 7 days, 0:00:00 on wtp[1027,1047-1048].eqiad.wmnet with reason: Downtiming replaced wtp servers
15:08 marostegui@cumin1001: dbctl commit (dc=all): 'db1173 (re)pooling @ 50%: Pooling after maintenance', diff saved to https://phabricator.wikimedia.org/P34121 and previous config saved to /var/cache/conftool/dbconfig/20220907-150817-root.json
15:07 claime: depooled wtp1026.eqiad.wmnet from parsoid cluster T307219
14:54 akosiaris@cumin1001: END (PASS) - Cookbook sre.hosts.reimage (exit_code=0) for host rdb1010.eqiad.wmnet with OS bullseye
14:53 marostegui@cumin1001: dbctl commit (dc=all): 'db1173 (re)pooling @ 25%: Pooling after maintenance', diff saved to https://phabricator.wikimedia.org/P34119 and previous config saved to /var/cache/conftool/dbconfig/20220907-145313-root.json
14:52 claime: pooled parse1018.eqiad.wmnet (php 7.4 only) in parsoid cluster T307219
14:50 cgoubert@cumin1001: END (PASS) - Cookbook sre.hosts.remove-downtime (exit_code=0) for parse1018.eqiad.wmnet
14:50 cgoubert@cumin1001: START - Cookbook sre.hosts.remove-downtime for parse1018.eqiad.wmnet
14:50 marostegui@cumin1001: dbctl commit (dc=all): 'db1118 (re)pooling @ 50%: Pooling after maintenance', diff saved to https://phabricator.wikimedia.org/P34118 and previous config saved to /var/cache/conftool/dbconfig/20220907-145018-root.json
14:48 claime: depooled wtp1025.eqiad.wmnet from parsoid cluster T307219
14:44 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db1169', diff saved to https://phabricator.wikimedia.org/P34117 and previous config saved to /var/cache/conftool/dbconfig/20220907-144434-ladsgroup.json
14:39 akosiaris@cumin1001: END (PASS) - Cookbook sre.hosts.downtime (exit_code=0) for 2:00:00 on rdb1010.eqiad.wmnet with reason: host reimage
14:38 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db1169', diff saved to https://phabricator.wikimedia.org/P34116 and previous config saved to /var/cache/conftool/dbconfig/20220907-143828-ladsgroup.json
14:38 marostegui@cumin1001: dbctl commit (dc=all): 'db1173 (re)pooling @ 10%: Pooling after maintenance', diff saved to https://phabricator.wikimedia.org/P34115 and previous config saved to /var/cache/conftool/dbconfig/20220907-143808-root.json
14:37 claime: pooled parse1017.eqiad.wmnet (php 7.4 only) in parsoid cluster T307219
14:36 jbond@cumin1001: END (PASS) - Cookbook sre.puppet.sync-netbox-hiera (exit_code=0) generate netbox hiera data: "sync data - jbond@cumin1001"
14:35 akosiaris@cumin1001: START - Cookbook sre.hosts.downtime for 2:00:00 on rdb1010.eqiad.wmnet with reason: host reimage
14:35 cgoubert@cumin1001: END (PASS) - Cookbook sre.hosts.remove-downtime (exit_code=0) for parse1017.eqiad.wmnet
14:35 cgoubert@cumin1001: START - Cookbook sre.hosts.remove-downtime for parse1017.eqiad.wmnet
14:23 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db1169', diff saved to https://phabricator.wikimedia.org/P34113 and previous config saved to /var/cache/conftool/dbconfig/20220907-142321-ladsgroup.json
14:20 claime: Switching canaries for parsoid eqiad T307219
14:20 marostegui@cumin1001: dbctl commit (dc=all): 'db1118 (re)pooling @ 10%: Pooling after maintenance', diff saved to https://phabricator.wikimedia.org/P34111 and previous config saved to /var/cache/conftool/dbconfig/20220907-142008-root.json
14:08 akosiaris@cumin1001: END (PASS) - Cookbook sre.hosts.reimage (exit_code=0) for host rdb1009.eqiad.wmnet with OS bullseye
14:08 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db1169 (T312863)', diff saved to https://phabricator.wikimedia.org/P34110 and previous config saved to /var/cache/conftool/dbconfig/20220907-140813-ladsgroup.json
14:07 marostegui@cumin1001: dbctl commit (dc=all): 'db1173 (re)pooling @ 1%: Pooling after maintenance', diff saved to https://phabricator.wikimedia.org/P34109 and previous config saved to /var/cache/conftool/dbconfig/20220907-140758-root.json
14:05 marostegui@cumin1001: dbctl commit (dc=all): 'db1118 (re)pooling @ 5%: Pooling after maintenance', diff saved to https://phabricator.wikimedia.org/P34108 and previous config saved to /var/cache/conftool/dbconfig/20220907-140503-root.json
14:02 claime: depooled wtp1027.eqiad.wmnet from parsoid cluster T307219
13:42 samtar@deploy1002: samtar and samtar: Backport for private/readme.php: Add $wgPhonosApiKeyGoogle (T315491) synced to the testservers: mwdebug1001.eqiad.wmnet, mwdebug2002.codfw.wmnet, mwdebug2001.codfw.wmnet, mwdebug1002.eqiad.wmnet
13:36 akosiaris@cumin1001: START - Cookbook sre.hosts.reimage for host rdb1009.eqiad.wmnet with OS bullseye
13:12 marostegui@cumin1001: dbctl commit (dc=all): 'db2122 (re)pooling @ 100%: Pooling after upgrade', diff saved to https://phabricator.wikimedia.org/P34107 and previous config saved to /var/cache/conftool/dbconfig/20220907-131223-root.json
12:57 marostegui@cumin1001: dbctl commit (dc=all): 'db2122 (re)pooling @ 75%: Pooling after upgrade', diff saved to https://phabricator.wikimedia.org/P34106 and previous config saved to /var/cache/conftool/dbconfig/20220907-125718-root.json
12:57 marostegui@cumin1001: dbctl commit (dc=all): 'db2120 (re)pooling @ 100%: Pooling after cloning another host', diff saved to https://phabricator.wikimedia.org/P34105 and previous config saved to /var/cache/conftool/dbconfig/20220907-125706-root.json
12:42 marostegui@cumin1001: dbctl commit (dc=all): 'db2122 (re)pooling @ 50%: Pooling after upgrade', diff saved to https://phabricator.wikimedia.org/P34104 and previous config saved to /var/cache/conftool/dbconfig/20220907-124213-root.json
12:42 marostegui@cumin1001: dbctl commit (dc=all): 'db2120 (re)pooling @ 75%: Pooling after cloning another host', diff saved to https://phabricator.wikimedia.org/P34103 and previous config saved to /var/cache/conftool/dbconfig/20220907-124201-root.json
12:31 jbond: re-enable puppet
12:27 moritzm: installing runc security updates on codfw staging hosts
12:27 marostegui@cumin1001: dbctl commit (dc=all): 'db2122 (re)pooling @ 25%: Pooling after upgrade', diff saved to https://phabricator.wikimedia.org/P34102 and previous config saved to /var/cache/conftool/dbconfig/20220907-122708-root.json
12:26 marostegui@cumin1001: dbctl commit (dc=all): 'db2120 (re)pooling @ 50%: Pooling after cloning another host', diff saved to https://phabricator.wikimedia.org/P34101 and previous config saved to /var/cache/conftool/dbconfig/20220907-122656-root.json
12:12 marostegui@cumin1001: dbctl commit (dc=all): 'db2122 (re)pooling @ 10%: Pooling after upgrade', diff saved to https://phabricator.wikimedia.org/P34100 and previous config saved to /var/cache/conftool/dbconfig/20220907-121204-root.json
12:11 marostegui@cumin1001: dbctl commit (dc=all): 'db2120 (re)pooling @ 25%: Pooling after cloning another host', diff saved to https://phabricator.wikimedia.org/P34099 and previous config saved to /var/cache/conftool/dbconfig/20220907-121152-root.json
12:08 jbond: disable puppet fleet wide to fix issues
11:56 marostegui@cumin1001: dbctl commit (dc=all): 'db2122 (re)pooling @ 5%: Pooling after upgrade', diff saved to https://phabricator.wikimedia.org/P34098 and previous config saved to /var/cache/conftool/dbconfig/20220907-115659-root.json
11:56 marostegui@cumin1001: dbctl commit (dc=all): 'db2120 (re)pooling @ 10%: Pooling after cloning another host', diff saved to https://phabricator.wikimedia.org/P34097 and previous config saved to /var/cache/conftool/dbconfig/20220907-115647-root.json
11:41 marostegui@cumin1001: dbctl commit (dc=all): 'db2122 (re)pooling @ 1%: Pooling after upgrade', diff saved to https://phabricator.wikimedia.org/P34096 and previous config saved to /var/cache/conftool/dbconfig/20220907-114154-root.json
11:41 marostegui@cumin1001: dbctl commit (dc=all): 'db2120 (re)pooling @ 5%: Pooling after cloning another host', diff saved to https://phabricator.wikimedia.org/P34095 and previous config saved to /var/cache/conftool/dbconfig/20220907-114142-root.json
11:18 marostegui@cumin1001: dbctl commit (dc=all): 'db1201 (re)pooling @ 100%: Pooling for the first time', diff saved to https://phabricator.wikimedia.org/P34094 and previous config saved to /var/cache/conftool/dbconfig/20220907-111821-root.json
11:03 marostegui@cumin1001: dbctl commit (dc=all): 'db1201 (re)pooling @ 75%: Pooling for the first time', diff saved to https://phabricator.wikimedia.org/P34093 and previous config saved to /var/cache/conftool/dbconfig/20220907-110316-root.json
11:00 cgoubert@cumin1001: END (PASS) - Cookbook sre.hosts.downtime (exit_code=0) for 7 days, 0:00:00 on 7 hosts with reason: Downtime pending inclusion in production
11:00 cgoubert@cumin1001: START - Cookbook sre.hosts.downtime for 7 days, 0:00:00 on 7 hosts with reason: Downtime pending inclusion in production
10:52 cgoubert@cumin1001: END (PASS) - Cookbook sre.hosts.downtime (exit_code=0) for 7 days, 0:00:00 on wtp[1044-1046].eqiad.wmnet with reason: Downtiming replaced wtp servers
10:52 cgoubert@cumin1001: START - Cookbook sre.hosts.downtime for 7 days, 0:00:00 on wtp[1044-1046].eqiad.wmnet with reason: Downtiming replaced wtp servers
10:48 marostegui@cumin1001: dbctl commit (dc=all): 'db1201 (re)pooling @ 50%: Pooling for the first time', diff saved to https://phabricator.wikimedia.org/P34092 and previous config saved to /var/cache/conftool/dbconfig/20220907-104811-root.json
10:40 claime: pooled parse1016.eqiad.wmnet (php 7.4 only) in parsoid cluster T307219
10:39 cgoubert@cumin1001: END (PASS) - Cookbook sre.hosts.remove-downtime (exit_code=0) for parse1016.eqiad.wmnet
10:39 cgoubert@cumin1001: START - Cookbook sre.hosts.remove-downtime for parse1016.eqiad.wmnet
10:36 claime: depooled wtp1048.eqiad.wmnet from parsoid cluster T307219
10:33 marostegui@cumin1001: dbctl commit (dc=all): 'db1201 (re)pooling @ 25%: Pooling for the first time', diff saved to https://phabricator.wikimedia.org/P34091 and previous config saved to /var/cache/conftool/dbconfig/20220907-103306-root.json
10:26 claime: pooled parse1015.eqiad.wmnet (php 7.4 only) in parsoid cluster T307219
10:25 cgoubert@cumin1001: END (PASS) - Cookbook sre.hosts.remove-downtime (exit_code=0) for parse1015.eqiad.wmnet
10:25 cgoubert@cumin1001: START - Cookbook sre.hosts.remove-downtime for parse1015.eqiad.wmnet
10:21 claime: depooled wtp1047.eqiad.wmnet from parsoid cluster T307219
10:18 marostegui@cumin1001: dbctl commit (dc=all): 'db1201 (re)pooling @ 10%: Pooling for the first time', diff saved to https://phabricator.wikimedia.org/P34089 and previous config saved to /var/cache/conftool/dbconfig/20220907-101801-root.json
10:17 marostegui@cumin1001: dbctl commit (dc=all): 'db1200 (re)pooling @ 100%: Pooling for the first time', diff saved to https://phabricator.wikimedia.org/P34088 and previous config saved to /var/cache/conftool/dbconfig/20220907-101734-root.json
10:12 marostegui@cumin1001: dbctl commit (dc=all): 'Depool db2120 to clone db2122', diff saved to https://phabricator.wikimedia.org/P34086 and previous config saved to /var/cache/conftool/dbconfig/20220907-101258-root.json
10:05 claime: pooled parse1014.eqiad.wmnet (php 7.4 only) in parsoid cluster T307219
10:02 marostegui@cumin1001: dbctl commit (dc=all): 'db1201 (re)pooling @ 5%: Pooling for the first time', diff saved to https://phabricator.wikimedia.org/P34085 and previous config saved to /var/cache/conftool/dbconfig/20220907-100257-root.json
10:02 marostegui@cumin1001: dbctl commit (dc=all): 'db1200 (re)pooling @ 75%: Pooling for the first time', diff saved to https://phabricator.wikimedia.org/P34084 and previous config saved to /var/cache/conftool/dbconfig/20220907-100229-root.json
09:57 cgoubert@cumin1001: END (PASS) - Cookbook sre.hosts.remove-downtime (exit_code=0) for parse1014.eqiad.wmnet
09:57 cgoubert@cumin1001: START - Cookbook sre.hosts.remove-downtime for parse1014.eqiad.wmnet
09:48 marostegui@cumin1001: dbctl commit (dc=all): 'db1199 (re)pooling @ 100%: Pooling for the first time in s4', diff saved to https://phabricator.wikimedia.org/P34083 and previous config saved to /var/cache/conftool/dbconfig/20220907-094825-root.json
09:48 topranks: Re-pooling eqsin for user traffic after successful core router upgrades - T295690
09:47 marostegui@cumin1001: dbctl commit (dc=all): 'db1201 (re)pooling @ 4%: Pooling for the first time', diff saved to https://phabricator.wikimedia.org/P34082 and previous config saved to /var/cache/conftool/dbconfig/20220907-094752-root.json
09:47 marostegui@cumin1001: dbctl commit (dc=all): 'db1200 (re)pooling @ 50%: Pooling for the first time', diff saved to https://phabricator.wikimedia.org/P34081 and previous config saved to /var/cache/conftool/dbconfig/20220907-094724-root.json
09:44 claime: depooled wtp1046.eqiad.wmnet from parsoid cluster T307219
09:37 marostegui@cumin1001: dbctl commit (dc=all): 'db1172 (re)pooling @ 100%: Repooling after cloning another host', diff saved to https://phabricator.wikimedia.org/P34080 and previous config saved to /var/cache/conftool/dbconfig/20220907-093736-root.json
09:35 cgoubert@cumin1001: END (PASS) - Cookbook sre.hosts.remove-downtime (exit_code=0) for parse1013.eqiad.wmnet
09:35 cgoubert@cumin1001: START - Cookbook sre.hosts.remove-downtime for parse1013.eqiad.wmnet
09:33 marostegui@cumin1001: dbctl commit (dc=all): 'db1199 (re)pooling @ 75%: Pooling for the first time in s4', diff saved to https://phabricator.wikimedia.org/P34079 and previous config saved to /var/cache/conftool/dbconfig/20220907-093320-root.json
09:32 marostegui@cumin1001: dbctl commit (dc=all): 'db1201 (re)pooling @ 3%: Pooling for the first time', diff saved to https://phabricator.wikimedia.org/P34078 and previous config saved to /var/cache/conftool/dbconfig/20220907-093247-root.json
09:32 marostegui@cumin1001: dbctl commit (dc=all): 'db1200 (re)pooling @ 25%: Pooling for the first time', diff saved to https://phabricator.wikimedia.org/P34077 and previous config saved to /var/cache/conftool/dbconfig/20220907-093219-root.json
09:31 claime: pooled parse1013.eqiad.wmnet (php 7.4 only) in parsoid cluster T307219
09:26 godog: restart swift-proxy and repool ms-fe1012
09:22 marostegui@cumin1001: dbctl commit (dc=all): 'db1172 (re)pooling @ 75%: Repooling after cloning another host', diff saved to https://phabricator.wikimedia.org/P34076 and previous config saved to /var/cache/conftool/dbconfig/20220907-092230-root.json
09:20 topranks: rebooting cr3-eqsin to complete JunOS upgrade
09:20 cmooney@cumin1001: END (PASS) - Cookbook sre.hosts.downtime (exit_code=0) for 1:00:00 on cr3-eqsin with reason: router upgrade
09:19 cmooney@cumin1001: START - Cookbook sre.hosts.downtime for 1:00:00 on cr3-eqsin with reason: router upgrade
09:18 marostegui@cumin1001: dbctl commit (dc=all): 'db1199 (re)pooling @ 50%: Pooling for the first time in s4', diff saved to https://phabricator.wikimedia.org/P34075 and previous config saved to /var/cache/conftool/dbconfig/20220907-091815-root.json
09:17 marostegui@cumin1001: dbctl commit (dc=all): 'db1201 (re)pooling @ 2%: Pooling for the first time', diff saved to https://phabricator.wikimedia.org/P34074 and previous config saved to /var/cache/conftool/dbconfig/20220907-091740-root.json
09:17 marostegui@cumin1001: dbctl commit (dc=all): 'db1200 (re)pooling @ 10%: Pooling for the first time', diff saved to https://phabricator.wikimedia.org/P34073 and previous config saved to /var/cache/conftool/dbconfig/20220907-091715-root.json
09:08 marostegui@cumin1001: dbctl commit (dc=all): 'db1198 (re)pooling @ 100%: Pooling for the first time in s3', diff saved to https://phabricator.wikimedia.org/P34072 and previous config saved to /var/cache/conftool/dbconfig/20220907-090830-root.json
09:07 marostegui@cumin1001: dbctl commit (dc=all): 'db1172 (re)pooling @ 50%: Repooling after cloning another host', diff saved to https://phabricator.wikimedia.org/P34071 and previous config saved to /var/cache/conftool/dbconfig/20220907-090725-root.json
09:03 marostegui@cumin1001: dbctl commit (dc=all): 'db1199 (re)pooling @ 25%: Pooling for the first time in s4', diff saved to https://phabricator.wikimedia.org/P34070 and previous config saved to /var/cache/conftool/dbconfig/20220907-090310-root.json
09:02 marostegui@cumin1001: dbctl commit (dc=all): 'db1200 (re)pooling @ 5%: Pooling for the first time', diff saved to https://phabricator.wikimedia.org/P34069 and previous config saved to /var/cache/conftool/dbconfig/20220907-090210-root.json
08:56 marostegui@cumin1001: dbctl commit (dc=all): 'db1174 (re)pooling @ 100%: Repooling after cloning another host', diff saved to https://phabricator.wikimedia.org/P34068 and previous config saved to /var/cache/conftool/dbconfig/20220907-085610-root.json
08:53 marostegui@cumin1001: dbctl commit (dc=all): 'db1198 (re)pooling @ 75%: Pooling for the first time in s3', diff saved to https://phabricator.wikimedia.org/P34067 and previous config saved to /var/cache/conftool/dbconfig/20220907-085325-root.json
08:52 marostegui@cumin1001: dbctl commit (dc=all): 'db1172 (re)pooling @ 25%: Repooling after cloning another host', diff saved to https://phabricator.wikimedia.org/P34066 and previous config saved to /var/cache/conftool/dbconfig/20220907-085220-root.json
08:51 topranks: rebooting cr2-eqsin to complete JunOS upgrade
08:48 marostegui@cumin1001: dbctl commit (dc=all): 'db1199 (re)pooling @ 10%: Pooling for the first time in s4', diff saved to https://phabricator.wikimedia.org/P34065 and previous config saved to /var/cache/conftool/dbconfig/20220907-084805-root.json
08:47 marostegui@cumin1001: dbctl commit (dc=all): 'db1200 (re)pooling @ 4%: Pooling for the first time', diff saved to https://phabricator.wikimedia.org/P34064 and previous config saved to /var/cache/conftool/dbconfig/20220907-084705-root.json
08:44 marostegui@cumin1001: dbctl commit (dc=all): 'Pooling db1201 for the first time in s6 T316342', diff saved to https://phabricator.wikimedia.org/P34063 and previous config saved to /var/cache/conftool/dbconfig/20220907-084454-marostegui.json
08:41 marostegui@cumin1001: dbctl commit (dc=all): 'Remove weight from x1 master', diff saved to https://phabricator.wikimedia.org/P34061 and previous config saved to /var/cache/conftool/dbconfig/20220907-084133-marostegui.json
08:41 marostegui@cumin1001: dbctl commit (dc=all): 'db1174 (re)pooling @ 75%: Repooling after cloning another host', diff saved to https://phabricator.wikimedia.org/P34060 and previous config saved to /var/cache/conftool/dbconfig/20220907-084105-root.json
08:40 marostegui@cumin1001: dbctl commit (dc=all): 'Add db1201 to s6, depooled, T316342', diff saved to https://phabricator.wikimedia.org/P34059 and previous config saved to /var/cache/conftool/dbconfig/20220907-084057-marostegui.json
08:39 marostegui@cumin1001: dbctl commit (dc=all): 'Depool db1131 (s6 master) from API', diff saved to https://phabricator.wikimedia.org/P34058 and previous config saved to /var/cache/conftool/dbconfig/20220907-083958-root.json
08:38 marostegui@cumin1001: dbctl commit (dc=all): 'db1198 (re)pooling @ 50%: Pooling for the first time in s3', diff saved to https://phabricator.wikimedia.org/P34057 and previous config saved to /var/cache/conftool/dbconfig/20220907-083820-root.json
08:37 marostegui@cumin1001: dbctl commit (dc=all): 'db2146 (re)pooling @ 100%: Repooling after upgrade', diff saved to https://phabricator.wikimedia.org/P34056 and previous config saved to /var/cache/conftool/dbconfig/20220907-083752-root.json
08:37 marostegui@cumin1001: dbctl commit (dc=all): 'db1172 (re)pooling @ 10%: Repooling after cloning another host', diff saved to https://phabricator.wikimedia.org/P34055 and previous config saved to /var/cache/conftool/dbconfig/20220907-083715-root.json
08:37 cmooney@cumin1001: END (PASS) - Cookbook sre.network.cf (exit_code=0)
08:35 cmooney@cumin1001: END (PASS) - Cookbook sre.hosts.downtime (exit_code=0) for 2:00:00 on cr2-eqsin with reason: router upgrade
08:35 cmooney@cumin1001: START - Cookbook sre.hosts.downtime for 2:00:00 on cr2-eqsin with reason: router upgrade
08:35 cmooney@cumin1001: END (FAIL) - Cookbook sre.hosts.downtime (exit_code=99) for 2:00:00 on cr2-eqsin.wikimedia.org with reason: router upgrade
08:35 cmooney@cumin1001: START - Cookbook sre.hosts.downtime for 2:00:00 on cr2-eqsin.wikimedia.org with reason: router upgrade
08:33 marostegui@cumin1001: dbctl commit (dc=all): 'db1199 (re)pooling @ 5%: Pooling for the first time in s4', diff saved to https://phabricator.wikimedia.org/P34054 and previous config saved to /var/cache/conftool/dbconfig/20220907-083300-root.json
08:32 marostegui@cumin1001: dbctl commit (dc=all): 'db1200 (re)pooling @ 3%: Pooling for the first time', diff saved to https://phabricator.wikimedia.org/P34053 and previous config saved to /var/cache/conftool/dbconfig/20220907-083200-root.json
08:25 marostegui@cumin1001: dbctl commit (dc=all): 'db1174 (re)pooling @ 50%: Repooling after cloning another host', diff saved to https://phabricator.wikimedia.org/P34052 and previous config saved to /var/cache/conftool/dbconfig/20220907-082554-root.json
08:23 marostegui@cumin1001: dbctl commit (dc=all): 'db1198 (re)pooling @ 25%: Pooling for the first time in s3', diff saved to https://phabricator.wikimedia.org/P34051 and previous config saved to /var/cache/conftool/dbconfig/20220907-082315-root.json
08:22 marostegui@cumin1001: dbctl commit (dc=all): 'db2146 (re)pooling @ 75%: Repooling after upgrade', diff saved to https://phabricator.wikimedia.org/P34050 and previous config saved to /var/cache/conftool/dbconfig/20220907-082247-root.json
08:22 marostegui@cumin1001: dbctl commit (dc=all): 'db1172 (re)pooling @ 5%: Repooling after cloning another host', diff saved to https://phabricator.wikimedia.org/P34049 and previous config saved to /var/cache/conftool/dbconfig/20220907-082210-root.json
08:18 marostegui@cumin1001: dbctl commit (dc=all): 'db1197 (re)pooling @ 100%: Pooling for the first time', diff saved to https://phabricator.wikimedia.org/P34048 and previous config saved to /var/cache/conftool/dbconfig/20220907-081826-root.json
08:17 marostegui@cumin1001: dbctl commit (dc=all): 'db1199 (re)pooling @ 4%: Pooling for the first time in s4', diff saved to https://phabricator.wikimedia.org/P34047 and previous config saved to /var/cache/conftool/dbconfig/20220907-081756-root.json
08:16 marostegui@cumin1001: dbctl commit (dc=all): 'db1200 (re)pooling @ 2%: Pooling for the first time', diff saved to https://phabricator.wikimedia.org/P34046 and previous config saved to /var/cache/conftool/dbconfig/20220907-081655-root.json
08:10 marostegui@cumin1001: dbctl commit (dc=all): 'db1174 (re)pooling @ 25%: Repooling after cloning another host', diff saved to https://phabricator.wikimedia.org/P34045 and previous config saved to /var/cache/conftool/dbconfig/20220907-081049-root.json
08:08 marostegui@cumin1001: dbctl commit (dc=all): 'Pooling db1200 for the first time in s5 T316342', diff saved to https://phabricator.wikimedia.org/P34044 and previous config saved to /var/cache/conftool/dbconfig/20220907-080825-marostegui.json
08:08 marostegui@cumin1001: dbctl commit (dc=all): 'db1198 (re)pooling @ 10%: Pooling for the first time in s3', diff saved to https://phabricator.wikimedia.org/P34043 and previous config saved to /var/cache/conftool/dbconfig/20220907-080810-root.json
08:07 marostegui@cumin1001: dbctl commit (dc=all): 'db2146 (re)pooling @ 50%: Repooling after upgrade', diff saved to https://phabricator.wikimedia.org/P34042 and previous config saved to /var/cache/conftool/dbconfig/20220907-080742-root.json
08:07 marostegui@cumin1001: dbctl commit (dc=all): 'db1172 (re)pooling @ 4%: Repooling after cloning another host', diff saved to https://phabricator.wikimedia.org/P34041 and previous config saved to /var/cache/conftool/dbconfig/20220907-080705-root.json
08:04 ladsgroup@cumin1001: dbctl commit (dc=all): 'Depooling db1169 (T312863)', diff saved to https://phabricator.wikimedia.org/P34040 and previous config saved to /var/cache/conftool/dbconfig/20220907-080449-ladsgroup.json
08:04 marostegui@cumin1001: dbctl commit (dc=all): 'db1196 (re)pooling @ 100%: Pooling for the first time', diff saved to https://phabricator.wikimedia.org/P34039 and previous config saved to /var/cache/conftool/dbconfig/20220907-080439-root.json
08:04 ladsgroup@cumin1001: END (PASS) - Cookbook sre.hosts.downtime (exit_code=0) for 1 day, 0:00:00 on db1169.eqiad.wmnet with reason: Maintenance
08:04 ladsgroup@cumin1001: START - Cookbook sre.hosts.downtime for 1 day, 0:00:00 on db1169.eqiad.wmnet with reason: Maintenance
08:03 marostegui@cumin1001: dbctl commit (dc=all): 'db1197 (re)pooling @ 75%: Pooling for the first time', diff saved to https://phabricator.wikimedia.org/P34038 and previous config saved to /var/cache/conftool/dbconfig/20220907-080321-root.json
08:02 marostegui@cumin1001: dbctl commit (dc=all): 'db1199 (re)pooling @ 3%: Pooling for the first time in s4', diff saved to https://phabricator.wikimedia.org/P34037 and previous config saved to /var/cache/conftool/dbconfig/20220907-080251-root.json
07:59 marostegui@cumin1001: dbctl commit (dc=all): 'Add db1200 to s5, depooled, T316342', diff saved to https://phabricator.wikimedia.org/P34036 and previous config saved to /var/cache/conftool/dbconfig/20220907-075919-marostegui.json
07:55 marostegui@cumin1001: dbctl commit (dc=all): 'db1174 (re)pooling @ 10%: Repooling after cloning another host', diff saved to https://phabricator.wikimedia.org/P34035 and previous config saved to /var/cache/conftool/dbconfig/20220907-075544-root.json
07:53 marostegui@cumin1001: dbctl commit (dc=all): 'db1198 (re)pooling @ 5%: Pooling for the first time in s3', diff saved to https://phabricator.wikimedia.org/P34034 and previous config saved to /var/cache/conftool/dbconfig/20220907-075305-root.json
07:52 marostegui@cumin1001: dbctl commit (dc=all): 'db2146 (re)pooling @ 25%: Repooling after upgrade', diff saved to https://phabricator.wikimedia.org/P34033 and previous config saved to /var/cache/conftool/dbconfig/20220907-075237-root.json
07:52 marostegui@cumin1001: dbctl commit (dc=all): 'db1172 (re)pooling @ 3%: Repooling after cloning another host', diff saved to https://phabricator.wikimedia.org/P34032 and previous config saved to /var/cache/conftool/dbconfig/20220907-075200-root.json
07:49 marostegui@cumin1001: dbctl commit (dc=all): 'db1196 (re)pooling @ 75%: Pooling for the first time', diff saved to https://phabricator.wikimedia.org/P34031 and previous config saved to /var/cache/conftool/dbconfig/20220907-074935-root.json
07:48 marostegui@cumin1001: dbctl commit (dc=all): 'db1197 (re)pooling @ 50%: Pooling for the first time', diff saved to https://phabricator.wikimedia.org/P34030 and previous config saved to /var/cache/conftool/dbconfig/20220907-074816-root.json
07:47 marostegui@cumin1001: dbctl commit (dc=all): 'db1199 (re)pooling @ 2%: Pooling for the first time in s4', diff saved to https://phabricator.wikimedia.org/P34029 and previous config saved to /var/cache/conftool/dbconfig/20220907-074746-root.json
07:46 marostegui@cumin1001: dbctl commit (dc=all): 'db1111 (re)pooling @ 100%: Repooling after upgrade', diff saved to https://phabricator.wikimedia.org/P34028 and previous config saved to /var/cache/conftool/dbconfig/20220907-074636-root.json
07:46 topranks: Depool eqsin from user traffic in advance of core router upgrades - T295690
07:44 jmm@cumin1001: END (FAIL) - Cookbook sre.hosts.reboot-single (exit_code=1) for host cumin2002.codfw.wmnet
07:40 marostegui@cumin1001: dbctl commit (dc=all): 'db1174 (re)pooling @ 5%: Repooling after cloning another host', diff saved to https://phabricator.wikimedia.org/P34027 and previous config saved to /var/cache/conftool/dbconfig/20220907-074039-root.json
07:38 marostegui@cumin1001: dbctl commit (dc=all): 'db1198 (re)pooling @ 4%: Pooling for the first time in s3', diff saved to https://phabricator.wikimedia.org/P34026 and previous config saved to /var/cache/conftool/dbconfig/20220907-073800-root.json
07:37 marostegui@cumin1001: dbctl commit (dc=all): 'Pooling db1199 for the first time in s4 T316342', diff saved to https://phabricator.wikimedia.org/P34025 and previous config saved to /var/cache/conftool/dbconfig/20220907-073745-marostegui.json
07:37 marostegui@cumin1001: dbctl commit (dc=all): 'db2146 (re)pooling @ 10%: Repooling after upgrade', diff saved to https://phabricator.wikimedia.org/P34024 and previous config saved to /var/cache/conftool/dbconfig/20220907-073732-root.json
07:37 marostegui@cumin1001: dbctl commit (dc=all): 'Add db1199 to s4, depooled, T316342', diff saved to https://phabricator.wikimedia.org/P34023 and previous config saved to /var/cache/conftool/dbconfig/20220907-073727-marostegui.json
07:36 marostegui@cumin1001: dbctl commit (dc=all): 'db1172 (re)pooling @ 2%: Repooling after cloning another host', diff saved to https://phabricator.wikimedia.org/P34022 and previous config saved to /var/cache/conftool/dbconfig/20220907-073655-root.json
07:34 marostegui@cumin1001: dbctl commit (dc=all): 'db1196 (re)pooling @ 50%: Pooling for the first time', diff saved to https://phabricator.wikimedia.org/P34021 and previous config saved to /var/cache/conftool/dbconfig/20220907-073430-root.json
07:33 jmm@cumin1001: START - Cookbook sre.hosts.reboot-single for host cumin2002.codfw.wmnet
07:33 marostegui@cumin1001: dbctl commit (dc=all): 'db1197 (re)pooling @ 25%: Pooling for the first time', diff saved to https://phabricator.wikimedia.org/P34020 and previous config saved to /var/cache/conftool/dbconfig/20220907-073311-root.json
07:32 ladsgroup@cumin1001: END (PASS) - Cookbook sre.hosts.downtime (exit_code=0) for 1 day, 0:00:00 on db2140.codfw.wmnet with reason: Maintenance
07:32 ladsgroup@cumin1001: START - Cookbook sre.hosts.downtime for 1 day, 0:00:00 on db2140.codfw.wmnet with reason: Maintenance
07:31 marostegui@cumin1001: dbctl commit (dc=all): 'db1111 (re)pooling @ 75%: Repooling after upgrade', diff saved to https://phabricator.wikimedia.org/P34019 and previous config saved to /var/cache/conftool/dbconfig/20220907-073131-root.json
07:28 ladsgroup@cumin1001: END (PASS) - Cookbook sre.hosts.downtime (exit_code=0) for 1 day, 0:00:00 on db2095.codfw.wmnet with reason: Maintenance
07:28 ladsgroup@cumin1001: START - Cookbook sre.hosts.downtime for 1 day, 0:00:00 on db2095.codfw.wmnet with reason: Maintenance
07:22 marostegui@cumin1001: dbctl commit (dc=all): 'db1198 (re)pooling @ 3%: Pooling for the first time in s3', diff saved to https://phabricator.wikimedia.org/P34018 and previous config saved to /var/cache/conftool/dbconfig/20220907-072255-root.json
07:22 marostegui@cumin1001: dbctl commit (dc=all): 'db2146 (re)pooling @ 5%: Repooling after upgrade', diff saved to https://phabricator.wikimedia.org/P34017 and previous config saved to /var/cache/conftool/dbconfig/20220907-072214-root.json
07:21 marostegui@cumin1001: dbctl commit (dc=all): 'db1172 (re)pooling @ 1%: Repooling after cloning another host', diff saved to https://phabricator.wikimedia.org/P34016 and previous config saved to /var/cache/conftool/dbconfig/20220907-072151-root.json
07:19 marostegui@cumin1001: dbctl commit (dc=all): 'db1196 (re)pooling @ 25%: Pooling for the first time', diff saved to https://phabricator.wikimedia.org/P34015 and previous config saved to /var/cache/conftool/dbconfig/20220907-071925-root.json
07:18 marostegui@cumin1001: dbctl commit (dc=all): 'db1197 (re)pooling @ 10%: Pooling for the first time', diff saved to https://phabricator.wikimedia.org/P34014 and previous config saved to /var/cache/conftool/dbconfig/20220907-071806-root.json
07:17 marostegui@cumin1001: dbctl commit (dc=all): 'Depool db2146 and db2122', diff saved to https://phabricator.wikimedia.org/P34013 and previous config saved to /var/cache/conftool/dbconfig/20220907-071744-root.json
07:16 marostegui@cumin1001: dbctl commit (dc=all): 'db1111 (re)pooling @ 50%: Repooling after upgrade', diff saved to https://phabricator.wikimedia.org/P34012 and previous config saved to /var/cache/conftool/dbconfig/20220907-071627-root.json
07:07 marostegui@cumin1001: dbctl commit (dc=all): 'db1198 (re)pooling @ 2%: Pooling for the first time in s3', diff saved to https://phabricator.wikimedia.org/P34011 and previous config saved to /var/cache/conftool/dbconfig/20220907-070750-root.json
07:04 marostegui@cumin1001: dbctl commit (dc=all): 'db1196 (re)pooling @ 10%: Pooling for the first time', diff saved to https://phabricator.wikimedia.org/P34010 and previous config saved to /var/cache/conftool/dbconfig/20220907-070420-root.json
07:03 marostegui@cumin1001: dbctl commit (dc=all): 'db1197 (re)pooling @ 5%: Pooling for the first time', diff saved to https://phabricator.wikimedia.org/P34009 and previous config saved to /var/cache/conftool/dbconfig/20220907-070301-root.json
07:01 marostegui@cumin1001: dbctl commit (dc=all): 'db1111 (re)pooling @ 25%: Repooling after upgrade', diff saved to https://phabricator.wikimedia.org/P34008 and previous config saved to /var/cache/conftool/dbconfig/20220907-070122-root.json
06:49 marostegui@cumin1001: dbctl commit (dc=all): 'db1196 (re)pooling @ 5%: Pooling for the first time', diff saved to https://phabricator.wikimedia.org/P34007 and previous config saved to /var/cache/conftool/dbconfig/20220907-064915-root.json
06:48 marostegui@cumin1001: dbctl commit (dc=all): 'Pooling db1198 for the first time in s3 T316342', diff saved to https://phabricator.wikimedia.org/P34006 and previous config saved to /var/cache/conftool/dbconfig/20220907-064831-marostegui.json
06:47 marostegui@cumin1001: dbctl commit (dc=all): 'db1197 (re)pooling @ 4%: Pooling for the first time', diff saved to https://phabricator.wikimedia.org/P34005 and previous config saved to /var/cache/conftool/dbconfig/20220907-064757-root.json
06:46 marostegui@cumin1001: dbctl commit (dc=all): 'db1111 (re)pooling @ 10%: Repooling after upgrade', diff saved to https://phabricator.wikimedia.org/P34004 and previous config saved to /var/cache/conftool/dbconfig/20220907-064617-root.json
06:45 marostegui@cumin1001: dbctl commit (dc=all): 'Add db1198 to s3, depooled, T316342', diff saved to https://phabricator.wikimedia.org/P34003 and previous config saved to /var/cache/conftool/dbconfig/20220907-064552-marostegui.json
06:34 marostegui@cumin1001: dbctl commit (dc=all): 'db1196 (re)pooling @ 4%: Pooling for the first time', diff saved to https://phabricator.wikimedia.org/P34002 and previous config saved to /var/cache/conftool/dbconfig/20220907-063410-root.json
06:32 marostegui@cumin1001: dbctl commit (dc=all): 'db1197 (re)pooling @ 3%: Pooling for the first time', diff saved to https://phabricator.wikimedia.org/P34001 and previous config saved to /var/cache/conftool/dbconfig/20220907-063252-root.json
06:31 marostegui@cumin1001: dbctl commit (dc=all): 'db1111 (re)pooling @ 5%: Repooling after upgrade', diff saved to https://phabricator.wikimedia.org/P34000 and previous config saved to /var/cache/conftool/dbconfig/20220907-063112-root.json
06:19 marostegui@cumin1001: dbctl commit (dc=all): 'db1196 (re)pooling @ 3%: Pooling for the first time', diff saved to https://phabricator.wikimedia.org/P33999 and previous config saved to /var/cache/conftool/dbconfig/20220907-061906-root.json
06:17 marostegui@cumin1001: dbctl commit (dc=all): 'db1197 (re)pooling @ 2%: Pooling for the first time', diff saved to https://phabricator.wikimedia.org/P33998 and previous config saved to /var/cache/conftool/dbconfig/20220907-061747-root.json
06:16 marostegui@cumin1001: dbctl commit (dc=all): 'db1111 (re)pooling @ 4%: Repooling after upgrade', diff saved to https://phabricator.wikimedia.org/P33997 and previous config saved to /var/cache/conftool/dbconfig/20220907-061607-root.json
06:11 marostegui@cumin1001: dbctl commit (dc=all): 'Pooling db1197 for the first time in s2 T316342', diff saved to https://phabricator.wikimedia.org/P33996 and previous config saved to /var/cache/conftool/dbconfig/20220907-061147-marostegui.json
06:08 marostegui@cumin1001: dbctl commit (dc=all): 'Add db1197 to s2, depooled, T316342', diff saved to https://phabricator.wikimedia.org/P33995 and previous config saved to /var/cache/conftool/dbconfig/20220907-060828-marostegui.json
06:04 marostegui@cumin1001: dbctl commit (dc=all): 'db1196 (re)pooling @ 2%: Pooling for the first time', diff saved to https://phabricator.wikimedia.org/P33994 and previous config saved to /var/cache/conftool/dbconfig/20220907-060401-root.json
06:01 marostegui@cumin1001: dbctl commit (dc=all): 'db1111 (re)pooling @ 3%: Repooling after upgrade', diff saved to https://phabricator.wikimedia.org/P33993 and previous config saved to /var/cache/conftool/dbconfig/20220907-060102-root.json
05:52 marostegui@cumin1001: dbctl commit (dc=all): 'Pooling db1196 for the first time in s1 T316342', diff saved to https://phabricator.wikimedia.org/P33992 and previous config saved to /var/cache/conftool/dbconfig/20220907-055201-marostegui.json
05:49 marostegui@cumin1001: dbctl commit (dc=all): 'Add db1196 to s1, depooled, T316342', diff saved to https://phabricator.wikimedia.org/P33991 and previous config saved to /var/cache/conftool/dbconfig/20220907-054910-marostegui.json
05:45 marostegui@cumin1001: dbctl commit (dc=all): 'db1111 (re)pooling @ 2%: Repooling after upgrade', diff saved to https://phabricator.wikimedia.org/P33990 and previous config saved to /var/cache/conftool/dbconfig/20220907-054557-root.json
05:33 marostegui@cumin1001: dbctl commit (dc=all): 'Depool db1172 T316342', diff saved to https://phabricator.wikimedia.org/P33988 and previous config saved to /var/cache/conftool/dbconfig/20220907-053350-root.json
05:31 marostegui@cumin1001: dbctl commit (dc=all): 'Depool db1174 T316342', diff saved to https://phabricator.wikimedia.org/P33986 and previous config saved to /var/cache/conftool/dbconfig/20220907-053154-root.json
05:30 marostegui@cumin1001: dbctl commit (dc=all): 'db1111 (re)pooling @ 1%: Repooling after upgrade', diff saved to https://phabricator.wikimedia.org/P33985 and previous config saved to /var/cache/conftool/dbconfig/20220907-053053-root.json
02:27 ladsgroup@cumin1001: END (PASS) - Cookbook sre.hosts.downtime (exit_code=0) for 1 day, 0:00:00 on db1140.eqiad.wmnet with reason: Maintenance
02:27 ladsgroup@cumin1001: START - Cookbook sre.hosts.downtime for 1 day, 0:00:00 on db1140.eqiad.wmnet with reason: Maintenance
01:51 ladsgroup@cumin1001: dbctl commit (dc=all): 'Depooling db2140 (T314041)', diff saved to https://phabricator.wikimedia.org/P33983 and previous config saved to /var/cache/conftool/dbconfig/20220907-015138-ladsgroup.json
01:51 ladsgroup@cumin1001: END (PASS) - Cookbook sre.hosts.downtime (exit_code=0) for 1 day, 0:00:00 on db2140.codfw.wmnet with reason: Maintenance
01:51 ladsgroup@cumin1001: START - Cookbook sre.hosts.downtime for 1 day, 0:00:00 on db2140.codfw.wmnet with reason: Maintenance
01:51 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db2172 (T314041)', diff saved to https://phabricator.wikimedia.org/P33982 and previous config saved to /var/cache/conftool/dbconfig/20220907-015116-ladsgroup.json
2022-09-06
23:38 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db2114 (T314041)', diff saved to https://phabricator.wikimedia.org/P33981 and previous config saved to /var/cache/conftool/dbconfig/20220906-233809-ladsgroup.json
23:07 dzahn@cumin2002: END (PASS) - Cookbook sre.hosts.downtime (exit_code=0) for 6 days, 0:00:00 on phab1004.eqiad.wmnet with reason: new install
23:06 dzahn@cumin2002: START - Cookbook sre.hosts.downtime for 6 days, 0:00:00 on phab1004.eqiad.wmnet with reason: new install
22:24 ladsgroup@cumin1001: dbctl commit (dc=all): 'Depooling db2114 (T314041)', diff saved to https://phabricator.wikimedia.org/P33980 and previous config saved to /var/cache/conftool/dbconfig/20220906-222439-ladsgroup.json
22:24 ladsgroup@cumin1001: END (PASS) - Cookbook sre.hosts.downtime (exit_code=0) for 1 day, 0:00:00 on db2114.codfw.wmnet with reason: Maintenance
22:24 ladsgroup@cumin1001: START - Cookbook sre.hosts.downtime for 1 day, 0:00:00 on db2114.codfw.wmnet with reason: Maintenance
22:24 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db2117 (T314041)', diff saved to https://phabricator.wikimedia.org/P33979 and previous config saved to /var/cache/conftool/dbconfig/20220906-222418-ladsgroup.json
21:56 milimetric@deploy1002: Finished deploy [analytics/refinery@b14c9f4] (thin): Hotfix for requestctl field (duration: 00m 08s)
21:56 milimetric@deploy1002: Started deploy [analytics/refinery@b14c9f4] (thin): Hotfix for requestctl field
21:56 milimetric@deploy1002: Finished deploy [analytics/refinery@b14c9f4]: Hotfix for requestctl field (duration: 02m 28s)
21:53 milimetric@deploy1002: Started deploy [analytics/refinery@b14c9f4]: Hotfix for requestctl field
21:53 milimetric@deploy1002: Finished deploy [analytics/refinery@b14c9f4]: Hotfix for requestctl field (duration: 03m 28s)
21:49 milimetric@deploy1002: Started deploy [analytics/refinery@b14c9f4]: Hotfix for requestctl field
21:49 milimetric@deploy1002: Finished deploy [analytics/refinery@b14c9f4]: Hotfix for requestctl field (duration: 03m 55s)
21:45 milimetric@deploy1002: Started deploy [analytics/refinery@b14c9f4]: Hotfix for requestctl field
21:45 milimetric@deploy1002: deploy aborted: Hotfix for requestctl field (duration: 32m 09s)
21:41 root@cumin1001: END (PASS) - Cookbook sre.network.prepare-upgrade (exit_code=0)
21:39 mutante: phabricator - passive hosts in codfw switched to readonly DB access (m3-slave, not m3-master) T315713
21:30 root@cumin1001: END (ERROR) - Cookbook sre.network.prepare-upgrade (exit_code=97)
21:13 milimetric@deploy1002: Started deploy [analytics/refinery@b14c9f4]: Hotfix for requestctl field
20:42 cjming@deploy1002: cjming and mdsshakil: Backport for Add localized wordmark for Bengali Wiktionary (T316953) synced to the testservers: mwdebug1001.eqiad.wmnet, mwdebug2001.codfw.wmnet, mwdebug1002.eqiad.wmnet, mwdebug2002.codfw.wmnet
20:32 ladsgroup@cumin1001: dbctl commit (dc=all): 'Depooling db2117 (T314041)', diff saved to https://phabricator.wikimedia.org/P33978 and previous config saved to /var/cache/conftool/dbconfig/20220906-203258-ladsgroup.json
20:32 ladsgroup@cumin1001: END (PASS) - Cookbook sre.hosts.downtime (exit_code=0) for 1 day, 0:00:00 on db2117.codfw.wmnet with reason: Maintenance
20:32 ladsgroup@cumin1001: START - Cookbook sre.hosts.downtime for 1 day, 0:00:00 on db2117.codfw.wmnet with reason: Maintenance
20:32 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db2124 (T314041)', diff saved to https://phabricator.wikimedia.org/P33977 and previous config saved to /var/cache/conftool/dbconfig/20220906-203236-ladsgroup.json
20:27 ladsgroup@cumin1001: END (PASS) - Cookbook sre.hosts.downtime (exit_code=0) for 1 day, 0:00:00 on db1139.eqiad.wmnet with reason: Maintenance
20:26 ladsgroup@cumin1001: START - Cookbook sre.hosts.downtime for 1 day, 0:00:00 on db1139.eqiad.wmnet with reason: Maintenance
20:26 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db1135 (T312863)', diff saved to https://phabricator.wikimedia.org/P33976 and previous config saved to /var/cache/conftool/dbconfig/20220906-202654-ladsgroup.json
20:23 cjming@deploy1002: cjming and ebernhardson: Backport for Ensure namespace filters is passed as a list synced to the testservers: mwdebug2001.codfw.wmnet, mwdebug1001.eqiad.wmnet, mwdebug1002.eqiad.wmnet, mwdebug2002.codfw.wmnet
20:16 bd808: Forcing puppet runs on cloudweb100[34] to deploy new version of Striker (T296893)
20:13 bd808: Running database migrations for Striker (T296893)
20:11 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db1135', diff saved to https://phabricator.wikimedia.org/P33975 and previous config saved to /var/cache/conftool/dbconfig/20220906-201148-ladsgroup.json
20:03 inflatador: 'bking@cumin1001 disabling puppet on elastic codfw hosts T313431'
19:56 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db1135', diff saved to https://phabricator.wikimedia.org/P33974 and previous config saved to /var/cache/conftool/dbconfig/20220906-195642-ladsgroup.json
19:41 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db1135 (T312863)', diff saved to https://phabricator.wikimedia.org/P33973 and previous config saved to /var/cache/conftool/dbconfig/20220906-194135-ladsgroup.json
19:24 milimetric@deploy1002: Started deploy [analytics/refinery@8a5ce13]: Regular analytics weekly train [analytics/refinery@8a5ce13]
18:45 ladsgroup@cumin1001: dbctl commit (dc=all): 'Depooling db2124 (T314041)', diff saved to https://phabricator.wikimedia.org/P33972 and previous config saved to /var/cache/conftool/dbconfig/20220906-184515-ladsgroup.json
18:45 ladsgroup@cumin1001: END (PASS) - Cookbook sre.hosts.downtime (exit_code=0) for 1 day, 0:00:00 on db2124.codfw.wmnet with reason: Maintenance
18:44 ladsgroup@cumin1001: START - Cookbook sre.hosts.downtime for 1 day, 0:00:00 on db2124.codfw.wmnet with reason: Maintenance
18:25 cwhite: reduce codfw replicas 2 to 1 for logstash-(webrequest|k8s) partitions. Make space for failed logstash2027 - T316996
17:06 krinkle@deploy1002: Synchronized wmf-config/: (no justification provided) (duration: 03m 50s)
17:02 pt1979@cumin2002: END (PASS) - Cookbook sre.hardware.upgrade-firmware (exit_code=0) upgrade firmware for hosts ['kafka-logging1004']
17:00 ladsgroup@cumin1001: END (PASS) - Cookbook sre.hosts.downtime (exit_code=0) for 1 day, 0:00:00 on db2141.codfw.wmnet with reason: Maintenance
17:00 ladsgroup@cumin1001: START - Cookbook sre.hosts.downtime for 1 day, 0:00:00 on db2141.codfw.wmnet with reason: Maintenance
17:00 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db2158 (T314041)', diff saved to https://phabricator.wikimedia.org/P33969 and previous config saved to /var/cache/conftool/dbconfig/20220906-165958-ladsgroup.json
16:12 ayounsi@cumin1001: END (PASS) - Cookbook sre.network.prepare-upgrade (exit_code=0)
16:12 pt1979@cumin2002: END (PASS) - Cookbook sre.hosts.provision (exit_code=0) for host kafka-logging1004.mgmt.eqiad.wmnet with reboot policy FORCED
16:01 jelto@cumin1001: START - Cookbook sre.gitlab.reboot-runner rolling reboot on A:gitlab-runner
15:50 marostegui@cumin1001: dbctl commit (dc=all): 'db1180 (re)pooling @ 100%: Repooling after cloning another host', diff saved to https://phabricator.wikimedia.org/P33968 and previous config saved to /var/cache/conftool/dbconfig/20220906-154959-root.json
15:34 marostegui@cumin1001: dbctl commit (dc=all): 'db1180 (re)pooling @ 75%: Repooling after cloning another host', diff saved to https://phabricator.wikimedia.org/P33967 and previous config saved to /var/cache/conftool/dbconfig/20220906-153454-root.json
15:21 jelto@cumin1001: END (FAIL) - Cookbook sre.gitlab.reboot-runner (exit_code=1) rolling reboot on A:gitlab-runner
15:20 jelto@cumin1001: START - Cookbook sre.gitlab.reboot-runner rolling reboot on A:gitlab-runner
15:19 marostegui@cumin1001: dbctl commit (dc=all): 'db1180 (re)pooling @ 50%: Repooling after cloning another host', diff saved to https://phabricator.wikimedia.org/P33966 and previous config saved to /var/cache/conftool/dbconfig/20220906-151950-root.json
15:15 claime: Set wtp10[41-43].eqiad.wmnet inactive pending decommission T317025
15:12 cgoubert@cumin1001: END (PASS) - Cookbook sre.hosts.downtime (exit_code=0) for 7 days, 0:00:00 on wtp[1041-1043].eqiad.wmnet with reason: Downtiming replaced wtp servers
15:12 cgoubert@cumin1001: START - Cookbook sre.hosts.downtime for 7 days, 0:00:00 on wtp[1041-1043].eqiad.wmnet with reason: Downtiming replaced wtp servers
15:09 ladsgroup@cumin1001: dbctl commit (dc=all): 'Depooling db2158 (T314041)', diff saved to https://phabricator.wikimedia.org/P33965 and previous config saved to /var/cache/conftool/dbconfig/20220906-150953-ladsgroup.json
15:09 ladsgroup@cumin1001: END (PASS) - Cookbook sre.hosts.downtime (exit_code=0) for 2 days, 0:00:00 on db2095.codfw.wmnet with reason: Maintenance
15:09 ladsgroup@cumin1001: START - Cookbook sre.hosts.downtime for 2 days, 0:00:00 on db2095.codfw.wmnet with reason: Maintenance
15:09 ladsgroup@cumin1001: END (PASS) - Cookbook sre.hosts.downtime (exit_code=0) for 1 day, 0:00:00 on db2158.codfw.wmnet with reason: Maintenance
15:09 ladsgroup@cumin1001: START - Cookbook sre.hosts.downtime for 1 day, 0:00:00 on db2158.codfw.wmnet with reason: Maintenance
15:09 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db2169:3316 (T314041)', diff saved to https://phabricator.wikimedia.org/P33964 and previous config saved to /var/cache/conftool/dbconfig/20220906-150928-ladsgroup.json
15:08 claime: depooled wtp1045.eqiad.wmnet from parsoid cluster T307219
15:04 marostegui@cumin1001: dbctl commit (dc=all): 'db1180 (re)pooling @ 25%: Repooling after cloning another host', diff saved to https://phabricator.wikimedia.org/P33963 and previous config saved to /var/cache/conftool/dbconfig/20220906-150445-root.json
14:58 claime: pooled parse1012.eqiad.wmnet (php 7.4 only) in parsoid cluster T307219
14:55 cgoubert@cumin1001: END (PASS) - Cookbook sre.hosts.remove-downtime (exit_code=0) for parse1012.eqiad.wmnet
14:55 cgoubert@cumin1001: START - Cookbook sre.hosts.remove-downtime for parse1012.eqiad.wmnet
14:53 pt1979@cumin2002: START - Cookbook sre.hosts.provision for host kafka-logging1004.mgmt.eqiad.wmnet with reboot policy FORCED
14:49 marostegui@cumin1001: dbctl commit (dc=all): 'db1180 (re)pooling @ 10%: Repooling after cloning another host', diff saved to https://phabricator.wikimedia.org/P33962 and previous config saved to /var/cache/conftool/dbconfig/20220906-144940-root.json
14:36 pt1979@cumin2002: END (PASS) - Cookbook sre.network.configure-switch-interfaces (exit_code=0) for host kafka-logging1004
14:36 pt1979@cumin2002: START - Cookbook sre.network.configure-switch-interfaces for host kafka-logging1004
14:34 marostegui@cumin1001: dbctl commit (dc=all): 'db1180 (re)pooling @ 5%: Repooling after cloning another host', diff saved to https://phabricator.wikimedia.org/P33961 and previous config saved to /var/cache/conftool/dbconfig/20220906-143435-root.json
13:56 claime: depooled wtp1043.eqiad.wmnet from parsoid cluster T307219
13:45 ladsgroup@cumin1001: dbctl commit (dc=all): 'Depooling db1135 (T312863)', diff saved to https://phabricator.wikimedia.org/P33960 and previous config saved to /var/cache/conftool/dbconfig/20220906-134545-ladsgroup.json
13:45 ladsgroup@cumin1001: END (PASS) - Cookbook sre.hosts.downtime (exit_code=0) for 1 day, 0:00:00 on db1135.eqiad.wmnet with reason: Maintenance
13:45 ladsgroup@cumin1001: START - Cookbook sre.hosts.downtime for 1 day, 0:00:00 on db1135.eqiad.wmnet with reason: Maintenance
13:45 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db1134 (T312863)', diff saved to https://phabricator.wikimedia.org/P33959 and previous config saved to /var/cache/conftool/dbconfig/20220906-134523-ladsgroup.json
13:35 claime: pooled parse1010.eqiad.wmnet (php 7.4 only) in parsoid cluster T307219
13:33 cgoubert@cumin1001: END (PASS) - Cookbook sre.hosts.remove-downtime (exit_code=0) for parse1010.eqiad.wmnet
13:33 cgoubert@cumin1001: START - Cookbook sre.hosts.remove-downtime for parse1010.eqiad.wmnet
13:30 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db1134', diff saved to https://phabricator.wikimedia.org/P33958 and previous config saved to /var/cache/conftool/dbconfig/20220906-133017-ladsgroup.json
13:26 marostegui@cumin1001: dbctl commit (dc=all): 'Depool db1180 T316342', diff saved to https://phabricator.wikimedia.org/P33956 and previous config saved to /var/cache/conftool/dbconfig/20220906-132627-root.json
13:21 TheresNoTime: closing UTC afternoon backport window
13:17 ladsgroup@cumin1001: dbctl commit (dc=all): 'Depooling db2169:3316 (T314041)', diff saved to https://phabricator.wikimedia.org/P33954 and previous config saved to /var/cache/conftool/dbconfig/20220906-131715-ladsgroup.json
13:17 ladsgroup@cumin1001: END (PASS) - Cookbook sre.hosts.downtime (exit_code=0) for 1 day, 0:00:00 on db2169.codfw.wmnet with reason: Maintenance
13:16 ladsgroup@cumin1001: START - Cookbook sre.hosts.downtime for 1 day, 0:00:00 on db2169.codfw.wmnet with reason: Maintenance
13:16 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db2180 (T314041)', diff saved to https://phabricator.wikimedia.org/P33953 and previous config saved to /var/cache/conftool/dbconfig/20220906-131654-ladsgroup.json
13:15 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db1134', diff saved to https://phabricator.wikimedia.org/P33952 and previous config saved to /var/cache/conftool/dbconfig/20220906-131510-ladsgroup.json
13:00 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db1134 (T312863)', diff saved to https://phabricator.wikimedia.org/P33951 and previous config saved to /var/cache/conftool/dbconfig/20220906-130004-ladsgroup.json
12:31 marostegui@cumin1001: dbctl commit (dc=all): 'db1138 (re)pooling @ 100%: Repooling after cloning another host', diff saved to https://phabricator.wikimedia.org/P33950 and previous config saved to /var/cache/conftool/dbconfig/20220906-123145-root.json
12:29 jmm@cumin2002: END (PASS) - Cookbook sre.hosts.downtime (exit_code=0) for 0:15:00 on puppetdb2002.codfw.wmnet with reason: Temporarily stop puppetdb/postgres
12:29 jmm@cumin2002: START - Cookbook sre.hosts.downtime for 0:15:00 on puppetdb2002.codfw.wmnet with reason: Temporarily stop puppetdb/postgres
12:16 marostegui@cumin1001: dbctl commit (dc=all): 'db1138 (re)pooling @ 75%: Repooling after cloning another host', diff saved to https://phabricator.wikimedia.org/P33949 and previous config saved to /var/cache/conftool/dbconfig/20220906-121640-root.json
12:05 claime: Set wtp10[38-40].eqiad.wmnet inactive pending decommission T317025
12:04 ladsgroup@cumin1001: dbctl commit (dc=all): 'Depooling db2180 (T314041)', diff saved to https://phabricator.wikimedia.org/P33948 and previous config saved to /var/cache/conftool/dbconfig/20220906-120433-ladsgroup.json
12:04 ladsgroup@cumin1001: END (PASS) - Cookbook sre.hosts.downtime (exit_code=0) for 1 day, 0:00:00 on db2180.codfw.wmnet with reason: Maintenance
12:04 ladsgroup@cumin1001: START - Cookbook sre.hosts.downtime for 1 day, 0:00:00 on db2180.codfw.wmnet with reason: Maintenance
12:04 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db2171:3316 (T314041)', diff saved to https://phabricator.wikimedia.org/P33947 and previous config saved to /var/cache/conftool/dbconfig/20220906-120412-ladsgroup.json
12:03 cgoubert@cumin1001: END (PASS) - Cookbook sre.hosts.downtime (exit_code=0) for 7 days, 0:00:00 on wtp[1039-1040].eqiad.wmnet with reason: Downtiming replaced wtp servers
12:02 cgoubert@cumin1001: START - Cookbook sre.hosts.downtime for 7 days, 0:00:00 on wtp[1039-1040].eqiad.wmnet with reason: Downtiming replaced wtp servers
12:01 marostegui@cumin1001: dbctl commit (dc=all): 'db1138 (re)pooling @ 50%: Repooling after cloning another host', diff saved to https://phabricator.wikimedia.org/P33946 and previous config saved to /var/cache/conftool/dbconfig/20220906-120135-root.json
12:01 claime: depooled wtp1042.eqiad.wmnet from parsoid cluster T307219
11:46 marostegui@cumin1001: dbctl commit (dc=all): 'db1138 (re)pooling @ 25%: Repooling after cloning another host', diff saved to https://phabricator.wikimedia.org/P33945 and previous config saved to /var/cache/conftool/dbconfig/20220906-114631-root.json
11:31 marostegui@cumin1001: dbctl commit (dc=all): 'db1138 (re)pooling @ 10%: Repooling after cloning another host', diff saved to https://phabricator.wikimedia.org/P33944 and previous config saved to /var/cache/conftool/dbconfig/20220906-113126-root.json
11:27 claime: pooled parse1009.eqiad.wmnet (php 7.4 only) in parsoid cluster T307219
11:26 jbond@cumin2002: END (PASS) - Cookbook sre.puppet.sync-netbox-hiera (exit_code=0) generate netbox hiera data: "sync data - jbond@cumin2002"
11:26 cgoubert@cumin1001: END (PASS) - Cookbook sre.hosts.downtime (exit_code=0) for 7 days, 0:00:00 on 12 hosts with reason: Downtime pending inclusion in production
11:26 cgoubert@cumin1001: START - Cookbook sre.hosts.downtime for 7 days, 0:00:00 on 12 hosts with reason: Downtime pending inclusion in production
11:17 XioNoX: put cr4-ulsfo back in service - T295690
11:16 marostegui@cumin1001: dbctl commit (dc=all): 'db1138 (re)pooling @ 5%: Repooling after cloning another host', diff saved to https://phabricator.wikimedia.org/P33943 and previous config saved to /var/cache/conftool/dbconfig/20220906-111621-root.json
11:11 moritzm: installing ghostscript updates on stretch
11:06 XioNoX: restart cr4-ulsfo for software upgrade - T295690
11:01 marostegui@cumin1001: dbctl commit (dc=all): 'db1138 (re)pooling @ 4%: Repooling after cloning another host', diff saved to https://phabricator.wikimedia.org/P33942 and previous config saved to /var/cache/conftool/dbconfig/20220906-110116-root.json
10:58 marostegui@cumin1001: dbctl commit (dc=all): 'db1189 (re)pooling @ 100%: Repooling after upgrade', diff saved to https://phabricator.wikimedia.org/P33941 and previous config saved to /var/cache/conftool/dbconfig/20220906-105841-root.json
10:58 cgoubert@cumin1001: END (PASS) - Cookbook sre.hosts.remove-downtime (exit_code=0) for parse1009.eqiad.wmnet
10:57 cgoubert@cumin1001: START - Cookbook sre.hosts.remove-downtime for parse1009.eqiad.wmnet
10:52 moritzm: uploaded ghostscript 9.26a~dfsg-0+deb9u9+wmf1 to apt.wikimedia.org
10:46 marostegui@cumin1001: dbctl commit (dc=all): 'db1138 (re)pooling @ 3%: Repooling after cloning another host', diff saved to https://phabricator.wikimedia.org/P33940 and previous config saved to /var/cache/conftool/dbconfig/20220906-104611-root.json
10:43 marostegui@cumin1001: dbctl commit (dc=all): 'db1189 (re)pooling @ 75%: Repooling after upgrade', diff saved to https://phabricator.wikimedia.org/P33939 and previous config saved to /var/cache/conftool/dbconfig/20220906-104336-root.json
10:42 XioNoX: drain traffic from cr4-ulsfo - T295690
10:40 jayme: switched primary kube-controller-manager from kubemaster1001 to kubemaster1002
10:34 marostegui@cumin1001: dbctl commit (dc=all): 'db1188 (re)pooling @ 100%: Repooling after upgrade', diff saved to https://phabricator.wikimedia.org/P33938 and previous config saved to /var/cache/conftool/dbconfig/20220906-103402-root.json
10:31 marostegui@cumin1001: dbctl commit (dc=all): 'db1138 (re)pooling @ 2%: Repooling after cloning another host', diff saved to https://phabricator.wikimedia.org/P33937 and previous config saved to /var/cache/conftool/dbconfig/20220906-103104-root.json
10:30 marostegui@cumin1001: dbctl commit (dc=all): 'db1174 (re)pooling @ 100%: Repooling after upgrade', diff saved to https://phabricator.wikimedia.org/P33936 and previous config saved to /var/cache/conftool/dbconfig/20220906-103017-root.json
10:29 marostegui@cumin1001: dbctl commit (dc=all): 'db1119 (re)pooling @ 100%: Repooling after upgrade', diff saved to https://phabricator.wikimedia.org/P33935 and previous config saved to /var/cache/conftool/dbconfig/20220906-102919-root.json
10:28 marostegui@cumin1001: dbctl commit (dc=all): 'db1189 (re)pooling @ 50%: Repooling after upgrade', diff saved to https://phabricator.wikimedia.org/P33934 and previous config saved to /var/cache/conftool/dbconfig/20220906-102831-root.json
10:21 marostegui@cumin1001: dbctl commit (dc=all): 'db1103 (re)pooling @ 100%: Repooling after upgrade', diff saved to https://phabricator.wikimedia.org/P33932 and previous config saved to /var/cache/conftool/dbconfig/20220906-102152-root.json
10:18 marostegui@cumin1001: dbctl commit (dc=all): 'db1188 (re)pooling @ 75%: Repooling after upgrade', diff saved to https://phabricator.wikimedia.org/P33931 and previous config saved to /var/cache/conftool/dbconfig/20220906-101858-root.json
10:15 marostegui@cumin1001: dbctl commit (dc=all): 'db1138 (re)pooling @ 1%: Repooling after cloning another host', diff saved to https://phabricator.wikimedia.org/P33930 and previous config saved to /var/cache/conftool/dbconfig/20220906-101559-root.json
10:15 marostegui@cumin1001: dbctl commit (dc=all): 'db1174 (re)pooling @ 75%: Repooling after upgrade', diff saved to https://phabricator.wikimedia.org/P33929 and previous config saved to /var/cache/conftool/dbconfig/20220906-101513-root.json
10:14 marostegui@cumin1001: dbctl commit (dc=all): 'db1119 (re)pooling @ 75%: Repooling after upgrade', diff saved to https://phabricator.wikimedia.org/P33928 and previous config saved to /var/cache/conftool/dbconfig/20220906-101414-root.json
10:13 marostegui@cumin1001: dbctl commit (dc=all): 'db1189 (re)pooling @ 25%: Repooling after upgrade', diff saved to https://phabricator.wikimedia.org/P33927 and previous config saved to /var/cache/conftool/dbconfig/20220906-101326-root.json
10:11 ladsgroup@cumin1001: dbctl commit (dc=all): 'Depooling db2171:3316 (T314041)', diff saved to https://phabricator.wikimedia.org/P33926 and previous config saved to /var/cache/conftool/dbconfig/20220906-101129-ladsgroup.json
10:11 ladsgroup@cumin1001: END (PASS) - Cookbook sre.hosts.downtime (exit_code=0) for 1 day, 0:00:00 on db2171.codfw.wmnet with reason: Maintenance
10:10 ladsgroup@cumin1001: START - Cookbook sre.hosts.downtime for 1 day, 0:00:00 on db2171.codfw.wmnet with reason: Maintenance
10:06 marostegui@cumin1001: dbctl commit (dc=all): 'db1107 (re)pooling @ 100%: Pooling for the first time', diff saved to https://phabricator.wikimedia.org/P33925 and previous config saved to /var/cache/conftool/dbconfig/20220906-100656-root.json
10:06 marostegui@cumin1001: dbctl commit (dc=all): 'db1103 (re)pooling @ 75%: Repooling after upgrade', diff saved to https://phabricator.wikimedia.org/P33924 and previous config saved to /var/cache/conftool/dbconfig/20220906-100647-root.json
10:03 marostegui@cumin1001: dbctl commit (dc=all): 'db1188 (re)pooling @ 50%: Repooling after upgrade', diff saved to https://phabricator.wikimedia.org/P33923 and previous config saved to /var/cache/conftool/dbconfig/20220906-100353-root.json
10:00 marostegui@cumin1001: dbctl commit (dc=all): 'db1174 (re)pooling @ 50%: Repooling after upgrade', diff saved to https://phabricator.wikimedia.org/P33921 and previous config saved to /var/cache/conftool/dbconfig/20220906-100008-root.json
09:59 marostegui@cumin1001: dbctl commit (dc=all): 'db1119 (re)pooling @ 50%: Repooling after upgrade', diff saved to https://phabricator.wikimedia.org/P33920 and previous config saved to /var/cache/conftool/dbconfig/20220906-095909-root.json
09:58 marostegui@cumin1001: dbctl commit (dc=all): 'db1189 (re)pooling @ 10%: Repooling after upgrade', diff saved to https://phabricator.wikimedia.org/P33919 and previous config saved to /var/cache/conftool/dbconfig/20220906-095821-root.json
09:57 marostegui@cumin1001: dbctl commit (dc=all): 'db1130 (re)pooling @ 100%: Repooling after upgrade', diff saved to https://phabricator.wikimedia.org/P33918 and previous config saved to /var/cache/conftool/dbconfig/20220906-095722-root.json
09:55 claime: depooled wtp1041.eqiad.wmnet from parsoid cluster T307219
09:51 marostegui@cumin1001: dbctl commit (dc=all): 'db1107 (re)pooling @ 75%: Pooling for the first time', diff saved to https://phabricator.wikimedia.org/P33917 and previous config saved to /var/cache/conftool/dbconfig/20220906-095151-root.json
09:51 marostegui@cumin1001: dbctl commit (dc=all): 'db1103 (re)pooling @ 50%: Repooling after upgrade', diff saved to https://phabricator.wikimedia.org/P33916 and previous config saved to /var/cache/conftool/dbconfig/20220906-095143-root.json
09:48 marostegui@cumin1001: dbctl commit (dc=all): 'db1188 (re)pooling @ 25%: Repooling after upgrade', diff saved to https://phabricator.wikimedia.org/P33915 and previous config saved to /var/cache/conftool/dbconfig/20220906-094848-root.json
09:45 marostegui@cumin1001: dbctl commit (dc=all): 'db1174 (re)pooling @ 25%: Repooling after upgrade', diff saved to https://phabricator.wikimedia.org/P33914 and previous config saved to /var/cache/conftool/dbconfig/20220906-094503-root.json
09:44 claime: pooled parse1008.eqiad.wmnet (php 7.4 only) in parsoid cluster T307219
09:44 marostegui@cumin1001: dbctl commit (dc=all): 'db1119 (re)pooling @ 25%: Repooling after upgrade', diff saved to https://phabricator.wikimedia.org/P33913 and previous config saved to /var/cache/conftool/dbconfig/20220906-094404-root.json
09:43 marostegui@cumin1001: dbctl commit (dc=all): 'db1189 (re)pooling @ 5%: Repooling after upgrade', diff saved to https://phabricator.wikimedia.org/P33912 and previous config saved to /var/cache/conftool/dbconfig/20220906-094316-root.json
09:42 marostegui@cumin1001: dbctl commit (dc=all): 'db1130 (re)pooling @ 75%: Repooling after upgrade', diff saved to https://phabricator.wikimedia.org/P33911 and previous config saved to /var/cache/conftool/dbconfig/20220906-094217-root.json
09:40 cgoubert@cumin1001: END (PASS) - Cookbook sre.hosts.remove-downtime (exit_code=0) for parse1008.eqiad.wmnet
09:40 cgoubert@cumin1001: START - Cookbook sre.hosts.remove-downtime for parse1008.eqiad.wmnet
09:36 marostegui@cumin1001: dbctl commit (dc=all): 'db1107 (re)pooling @ 50%: Pooling for the first time', diff saved to https://phabricator.wikimedia.org/P33910 and previous config saved to /var/cache/conftool/dbconfig/20220906-093646-root.json
09:36 marostegui@cumin1001: dbctl commit (dc=all): 'db1103 (re)pooling @ 25%: Repooling after upgrade', diff saved to https://phabricator.wikimedia.org/P33909 and previous config saved to /var/cache/conftool/dbconfig/20220906-093638-root.json
09:33 marostegui@cumin1001: dbctl commit (dc=all): 'db1188 (re)pooling @ 10%: Repooling after upgrade', diff saved to https://phabricator.wikimedia.org/P33908 and previous config saved to /var/cache/conftool/dbconfig/20220906-093343-root.json
09:26 ladsgroup@cumin1001: START - Cookbook sre.hosts.downtime for 1 day, 0:00:00 on db2172.codfw.wmnet with reason: Maintenance
09:26 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db2119 (T314041)', diff saved to https://phabricator.wikimedia.org/P33902 and previous config saved to /var/cache/conftool/dbconfig/20220906-092604-ladsgroup.json
09:22 btullis: installing istio configs to dse-k8s cluster
09:21 marostegui@cumin1001: dbctl commit (dc=all): 'db1107 (re)pooling @ 25%: Pooling for the first time', diff saved to https://phabricator.wikimedia.org/P33901 and previous config saved to /var/cache/conftool/dbconfig/20220906-092141-root.json
09:21 marostegui@cumin1001: dbctl commit (dc=all): 'db1103 (re)pooling @ 10%: Repooling after upgrade', diff saved to https://phabricator.wikimedia.org/P33900 and previous config saved to /var/cache/conftool/dbconfig/20220906-092133-root.json
09:18 marostegui@cumin1001: dbctl commit (dc=all): 'db1188 (re)pooling @ 5%: Repooling after upgrade', diff saved to https://phabricator.wikimedia.org/P33899 and previous config saved to /var/cache/conftool/dbconfig/20220906-091838-root.json
09:14 marostegui@cumin1001: dbctl commit (dc=all): 'db1174 (re)pooling @ 5%: Repooling after upgrade', diff saved to https://phabricator.wikimedia.org/P33898 and previous config saved to /var/cache/conftool/dbconfig/20220906-091453-root.json
09:13 marostegui@cumin1001: dbctl commit (dc=all): 'db1119 (re)pooling @ 5%: Repooling after upgrade', diff saved to https://phabricator.wikimedia.org/P33897 and previous config saved to /var/cache/conftool/dbconfig/20220906-091355-root.json
09:13 marostegui@cumin1001: dbctl commit (dc=all): 'db1189 (re)pooling @ 3%: Repooling after upgrade', diff saved to https://phabricator.wikimedia.org/P33896 and previous config saved to /var/cache/conftool/dbconfig/20220906-091307-root.json
09:12 marostegui@cumin1001: dbctl commit (dc=all): 'db1130 (re)pooling @ 25%: Repooling after upgrade', diff saved to https://phabricator.wikimedia.org/P33895 and previous config saved to /var/cache/conftool/dbconfig/20220906-091207-root.json
09:06 marostegui@cumin1001: dbctl commit (dc=all): 'db1107 (re)pooling @ 10%: Pooling for the first time', diff saved to https://phabricator.wikimedia.org/P33894 and previous config saved to /var/cache/conftool/dbconfig/20220906-090637-root.json
09:06 marostegui@cumin1001: dbctl commit (dc=all): 'db1103 (re)pooling @ 5%: Repooling after upgrade', diff saved to https://phabricator.wikimedia.org/P33893 and previous config saved to /var/cache/conftool/dbconfig/20220906-090628-root.json
09:03 marostegui@cumin1001: dbctl commit (dc=all): 'db1188 (re)pooling @ 4%: Repooling after upgrade', diff saved to https://phabricator.wikimedia.org/P33892 and previous config saved to /var/cache/conftool/dbconfig/20220906-090333-root.json
08:59 marostegui@cumin1001: dbctl commit (dc=all): 'db1174 (re)pooling @ 4%: Repooling after upgrade', diff saved to https://phabricator.wikimedia.org/P33891 and previous config saved to /var/cache/conftool/dbconfig/20220906-085948-root.json
08:58 marostegui@cumin1001: dbctl commit (dc=all): 'db1119 (re)pooling @ 4%: Repooling after upgrade', diff saved to https://phabricator.wikimedia.org/P33890 and previous config saved to /var/cache/conftool/dbconfig/20220906-085850-root.json
08:58 marostegui@cumin1001: dbctl commit (dc=all): 'db1189 (re)pooling @ 2%: Repooling after upgrade', diff saved to https://phabricator.wikimedia.org/P33889 and previous config saved to /var/cache/conftool/dbconfig/20220906-085802-root.json
08:57 marostegui@cumin1001: dbctl commit (dc=all): 'db1130 (re)pooling @ 10%: Repooling after upgrade', diff saved to https://phabricator.wikimedia.org/P33888 and previous config saved to /var/cache/conftool/dbconfig/20220906-085703-root.json
08:51 marostegui@cumin1001: dbctl commit (dc=all): 'db1107 (re)pooling @ 5%: Pooling for the first time', diff saved to https://phabricator.wikimedia.org/P33887 and previous config saved to /var/cache/conftool/dbconfig/20220906-085132-root.json
08:51 marostegui@cumin1001: dbctl commit (dc=all): 'db1103 (re)pooling @ 4%: Repooling after upgrade', diff saved to https://phabricator.wikimedia.org/P33886 and previous config saved to /var/cache/conftool/dbconfig/20220906-085123-root.json
08:48 marostegui@cumin1001: dbctl commit (dc=all): 'db1188 (re)pooling @ 3%: Repooling after upgrade', diff saved to https://phabricator.wikimedia.org/P33885 and previous config saved to /var/cache/conftool/dbconfig/20220906-084829-root.json
08:44 marostegui@cumin1001: dbctl commit (dc=all): 'db1174 (re)pooling @ 3%: Repooling after upgrade', diff saved to https://phabricator.wikimedia.org/P33884 and previous config saved to /var/cache/conftool/dbconfig/20220906-084443-root.json
08:43 marostegui@cumin1001: dbctl commit (dc=all): 'db1119 (re)pooling @ 3%: Repooling after upgrade', diff saved to https://phabricator.wikimedia.org/P33883 and previous config saved to /var/cache/conftool/dbconfig/20220906-084345-root.json
08:42 marostegui@cumin1001: dbctl commit (dc=all): 'db1189 (re)pooling @ 1%: Repooling after upgrade', diff saved to https://phabricator.wikimedia.org/P33882 and previous config saved to /var/cache/conftool/dbconfig/20220906-084257-root.json
08:42 XioNoX: restart cr3-ulsfo for software upgrade - T295690
08:41 marostegui@cumin1001: dbctl commit (dc=all): 'db1130 (re)pooling @ 5%: Repooling after upgrade', diff saved to https://phabricator.wikimedia.org/P33881 and previous config saved to /var/cache/conftool/dbconfig/20220906-084158-root.json
08:36 marostegui@cumin1001: dbctl commit (dc=all): 'db1107 (re)pooling @ 4%: Pooling for the first time', diff saved to https://phabricator.wikimedia.org/P33880 and previous config saved to /var/cache/conftool/dbconfig/20220906-083627-root.json
08:36 marostegui@cumin1001: dbctl commit (dc=all): 'db1103 (re)pooling @ 3%: Repooling after upgrade', diff saved to https://phabricator.wikimedia.org/P33879 and previous config saved to /var/cache/conftool/dbconfig/20220906-083619-root.json
08:33 marostegui@cumin1001: dbctl commit (dc=all): 'db1188 (re)pooling @ 2%: Repooling after upgrade', diff saved to https://phabricator.wikimedia.org/P33878 and previous config saved to /var/cache/conftool/dbconfig/20220906-083324-root.json
08:30 marostegui@cumin1001: dbctl commit (dc=all): 'db1143 (re)pooling @ 100%: Repooling again', diff saved to https://phabricator.wikimedia.org/P33876 and previous config saved to /var/cache/conftool/dbconfig/20220906-083019-root.json
08:30 marostegui@cumin1001: dbctl commit (dc=all): 'db1132 (re)pooling @ 100%: Repooling again', diff saved to https://phabricator.wikimedia.org/P33875 and previous config saved to /var/cache/conftool/dbconfig/20220906-083002-root.json
08:29 marostegui@cumin1001: dbctl commit (dc=all): 'Depool db1138 T316342', diff saved to https://phabricator.wikimedia.org/P33874 and previous config saved to /var/cache/conftool/dbconfig/20220906-082954-root.json
08:29 marostegui@cumin1001: dbctl commit (dc=all): 'db1174 (re)pooling @ 2%: Repooling after upgrade', diff saved to https://phabricator.wikimedia.org/P33873 and previous config saved to /var/cache/conftool/dbconfig/20220906-082939-root.json
08:28 marostegui@cumin1001: dbctl commit (dc=all): 'db1119 (re)pooling @ 2%: Repooling after upgrade', diff saved to https://phabricator.wikimedia.org/P33872 and previous config saved to /var/cache/conftool/dbconfig/20220906-082841-root.json
08:26 marostegui@cumin1001: dbctl commit (dc=all): 'db1130 (re)pooling @ 1%: Repooling after upgrade', diff saved to https://phabricator.wikimedia.org/P33871 and previous config saved to /var/cache/conftool/dbconfig/20220906-082653-root.json
08:25 ladsgroup@cumin1001: END (PASS) - Cookbook sre.hosts.downtime (exit_code=0) for 1 day, 0:00:00 on dbstore1005.eqiad.wmnet with reason: Maintenance
08:25 ladsgroup@cumin1001: START - Cookbook sre.hosts.downtime for 1 day, 0:00:00 on dbstore1005.eqiad.wmnet with reason: Maintenance
08:25 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db1098:3316 (T314041)', diff saved to https://phabricator.wikimedia.org/P33870 and previous config saved to /var/cache/conftool/dbconfig/20220906-082507-ladsgroup.json
08:24 ayounsi@cumin1001: END (PASS) - Cookbook sre.network.cf (exit_code=0)
08:21 marostegui@cumin1001: dbctl commit (dc=all): 'db1107 (re)pooling @ 3%: Pooling for the first time', diff saved to https://phabricator.wikimedia.org/P33869 and previous config saved to /var/cache/conftool/dbconfig/20220906-082122-root.json
08:21 marostegui@cumin1001: dbctl commit (dc=all): 'db1103 (re)pooling @ 2%: Repooling after upgrade', diff saved to https://phabricator.wikimedia.org/P33868 and previous config saved to /var/cache/conftool/dbconfig/20220906-082114-root.json
08:10 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db1098:3316', diff saved to https://phabricator.wikimedia.org/P33862 and previous config saved to /var/cache/conftool/dbconfig/20220906-081001-ladsgroup.json
08:09 jnuche@deploy1002: rebuilt and synchronized wikiversions files: group0 wikis to 1.39.0-wmf.28 refs T314189
08:06 marostegui@cumin1001: dbctl commit (dc=all): 'db1107 (re)pooling @ 2%: Pooling for the first time', diff saved to https://phabricator.wikimedia.org/P33861 and previous config saved to /var/cache/conftool/dbconfig/20220906-080618-root.json
08:06 marostegui@cumin1001: dbctl commit (dc=all): 'db1103 (re)pooling @ 1%: Repooling after upgrade', diff saved to https://phabricator.wikimedia.org/P33860 and previous config saved to /var/cache/conftool/dbconfig/20220906-080609-root.json
08:04 ayounsi@cumin1001: END (PASS) - Cookbook sre.network.prepare-upgrade (exit_code=0)
08:02 marostegui: Set x1 back to binlog_format=ROW
07:54 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db1098:3316', diff saved to https://phabricator.wikimedia.org/P33857 and previous config saved to /var/cache/conftool/dbconfig/20220906-075455-ladsgroup.json
07:52 XioNoX: depool ulsfo for routers upgrade - T295690
07:51 marostegui@cumin1001: dbctl commit (dc=all): 'db1107 (re)pooling @ 1%: Pooling for the first time', diff saved to https://phabricator.wikimedia.org/P33856 and previous config saved to /var/cache/conftool/dbconfig/20220906-075113-root.json
07:45 marostegui@cumin1001: dbctl commit (dc=all): 'db1143 (re)pooling @ 25%: Repooling again', diff saved to https://phabricator.wikimedia.org/P33855 and previous config saved to /var/cache/conftool/dbconfig/20220906-074504-root.json
07:44 marostegui@cumin1001: dbctl commit (dc=all): 'db1132 (re)pooling @ 25%: Repooling again', diff saved to https://phabricator.wikimedia.org/P33854 and previous config saved to /var/cache/conftool/dbconfig/20220906-074448-root.json
07:39 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db1098:3316 (T314041)', diff saved to https://phabricator.wikimedia.org/P33853 and previous config saved to /var/cache/conftool/dbconfig/20220906-073948-ladsgroup.json
07:34 marostegui@cumin1001: dbctl commit (dc=all): 'Depool db1130 T316342', diff saved to https://phabricator.wikimedia.org/P33851 and previous config saved to /var/cache/conftool/dbconfig/20220906-073434-root.json
07:30 marostegui@cumin1001: dbctl commit (dc=all): 'db1143 (re)pooling @ 10%: Repooling again', diff saved to https://phabricator.wikimedia.org/P33850 and previous config saved to /var/cache/conftool/dbconfig/20220906-072959-root.json
07:29 marostegui@cumin1001: dbctl commit (dc=all): 'db1132 (re)pooling @ 10%: Repooling again', diff saved to https://phabricator.wikimedia.org/P33849 and previous config saved to /var/cache/conftool/dbconfig/20220906-072943-root.json
07:26 ayounsi@cumin1001: END (PASS) - Cookbook sre.network.prepare-upgrade (exit_code=0)
06:14 marostegui@cumin1001: dbctl commit (dc=all): 'db1143 (re)pooling @ 1%: Repooling again', diff saved to https://phabricator.wikimedia.org/P33836 and previous config saved to /var/cache/conftool/dbconfig/20220906-061434-root.json
06:14 marostegui@cumin1001: dbctl commit (dc=all): 'db1132 (re)pooling @ 1%: Repooling again', diff saved to https://phabricator.wikimedia.org/P33835 and previous config saved to /var/cache/conftool/dbconfig/20220906-061419-root.json
06:11 ladsgroup@cumin1001: dbctl commit (dc=all): 'Depooling db1134 (T312863)', diff saved to https://phabricator.wikimedia.org/P33833 and previous config saved to /var/cache/conftool/dbconfig/20220906-061150-ladsgroup.json
06:11 ladsgroup@cumin1001: END (PASS) - Cookbook sre.hosts.downtime (exit_code=0) for 1 day, 0:00:00 on db1134.eqiad.wmnet with reason: Maintenance
06:11 ladsgroup@cumin1001: START - Cookbook sre.hosts.downtime for 1 day, 0:00:00 on db1134.eqiad.wmnet with reason: Maintenance
06:10 ladsgroup@cumin1001: END (PASS) - Cookbook sre.hosts.downtime (exit_code=0) for 1 day, 0:00:00 on db1118.eqiad.wmnet with reason: Maintenance
06:10 ladsgroup@cumin1001: START - Cookbook sre.hosts.downtime for 1 day, 0:00:00 on db1118.eqiad.wmnet with reason: Maintenance
06:08 marostegui@cumin1001: dbctl commit (dc=all): 'Give some weight to current x1 eqiad master', diff saved to https://phabricator.wikimedia.org/P33832 and previous config saved to /var/cache/conftool/dbconfig/20220906-060833-root.json
06:08 marostegui@cumin1001: dbctl commit (dc=all): 'Depool db1103 T316745', diff saved to https://phabricator.wikimedia.org/P33831 and previous config saved to /var/cache/conftool/dbconfig/20220906-060815-root.json
06:06 marostegui@cumin1001: dbctl commit (dc=all): 'Promote db1120 to x1 primary T316745', diff saved to https://phabricator.wikimedia.org/P33830 and previous config saved to /var/cache/conftool/dbconfig/20220906-060602-root.json
06:05 marostegui: Starting x1 eqiad failover from db1103 to db1120 - T316745
06:04 ladsgroup@cumin1001: dbctl commit (dc=all): 'Depool db1118 T316623', diff saved to https://phabricator.wikimedia.org/P33829 and previous config saved to /var/cache/conftool/dbconfig/20220906-060418-ladsgroup.json
06:00 ladsgroup@cumin1001: dbctl commit (dc=all): 'Promote db1163 to s1 primary and set section read-write T316623', diff saved to https://phabricator.wikimedia.org/P33828 and previous config saved to /var/cache/conftool/dbconfig/20220906-060055-ladsgroup.json
06:00 ladsgroup@cumin1001: dbctl commit (dc=all): 'Set s1 eqiad as read-only for maintenance - T316623', diff saved to https://phabricator.wikimedia.org/P33827 and previous config saved to /var/cache/conftool/dbconfig/20220906-060032-ladsgroup.json
06:00 Amir1: Starting s1 eqiad failover from db1118 to db1163 - T316623
05:32 marostegui@cumin1001: dbctl commit (dc=all): 'Add db1107 to dbctl depooled T316870', diff saved to https://phabricator.wikimedia.org/P33826 and previous config saved to /var/cache/conftool/dbconfig/20220906-053238-marostegui.json
05:26 ladsgroup@cumin1001: dbctl commit (dc=all): 'Depooling db1098:3316 (T314041)', diff saved to https://phabricator.wikimedia.org/P33825 and previous config saved to /var/cache/conftool/dbconfig/20220906-052609-ladsgroup.json
05:26 ladsgroup@cumin1001: END (PASS) - Cookbook sre.hosts.downtime (exit_code=0) for 1 day, 0:00:00 on db1098.eqiad.wmnet with reason: Maintenance
05:25 ladsgroup@cumin1001: START - Cookbook sre.hosts.downtime for 1 day, 0:00:00 on db1098.eqiad.wmnet with reason: Maintenance
05:25 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db1113:3316 (T314041)', diff saved to https://phabricator.wikimedia.org/P33824 and previous config saved to /var/cache/conftool/dbconfig/20220906-052547-ladsgroup.json
05:13 marostegui@cumin1001: dbctl commit (dc=all): 'Set db1120 with weight 0 T316745', diff saved to https://phabricator.wikimedia.org/P33823 and previous config saved to /var/cache/conftool/dbconfig/20220906-051304-root.json
05:12 marostegui@cumin1001: END (PASS) - Cookbook sre.hosts.downtime (exit_code=0) for 1:00:00 on 10 hosts with reason: Primary switchover x1 T316745
05:12 marostegui@cumin1001: START - Cookbook sre.hosts.downtime for 1:00:00 on 10 hosts with reason: Primary switchover x1 T316745
05:10 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db1113:3316', diff saved to https://phabricator.wikimedia.org/P33822 and previous config saved to /var/cache/conftool/dbconfig/20220906-051041-ladsgroup.json
05:06 ladsgroup@cumin1001: dbctl commit (dc=all): 'Set db1163 with weight 0 T316623', diff saved to https://phabricator.wikimedia.org/P33821 and previous config saved to /var/cache/conftool/dbconfig/20220906-050610-ladsgroup.json
05:05 ladsgroup@cumin1001: END (PASS) - Cookbook sre.hosts.downtime (exit_code=0) for 2:00:00 on 36 hosts with reason: Primary switchover s1 T316623
05:05 ladsgroup@cumin1001: START - Cookbook sre.hosts.downtime for 2:00:00 on 36 hosts with reason: Primary switchover s1 T316623
04:55 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db1113:3316', diff saved to https://phabricator.wikimedia.org/P33820 and previous config saved to /var/cache/conftool/dbconfig/20220906-045535-ladsgroup.json
04:40 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db1113:3316 (T314041)', diff saved to https://phabricator.wikimedia.org/P33819 and previous config saved to /var/cache/conftool/dbconfig/20220906-044029-ladsgroup.json
03:02 mwpresync@deploy1002: Started scap: testwikis wikis to 1.39.0-wmf.28 refs T314189
02:43 ladsgroup@cumin1001: dbctl commit (dc=all): 'Depooling db1113:3316 (T314041)', diff saved to https://phabricator.wikimedia.org/P33816 and previous config saved to /var/cache/conftool/dbconfig/20220906-024351-ladsgroup.json
02:43 ladsgroup@cumin1001: END (PASS) - Cookbook sre.hosts.downtime (exit_code=0) for 1 day, 0:00:00 on db1113.eqiad.wmnet with reason: Maintenance
02:43 ladsgroup@cumin1001: START - Cookbook sre.hosts.downtime for 1 day, 0:00:00 on db1113.eqiad.wmnet with reason: Maintenance
02:43 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db1096:3316 (T314041)', diff saved to https://phabricator.wikimedia.org/P33815 and previous config saved to /var/cache/conftool/dbconfig/20220906-024330-ladsgroup.json
02:28 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db1096:3316', diff saved to https://phabricator.wikimedia.org/P33814 and previous config saved to /var/cache/conftool/dbconfig/20220906-022824-ladsgroup.json
02:13 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db1096:3316', diff saved to https://phabricator.wikimedia.org/P33813 and previous config saved to /var/cache/conftool/dbconfig/20220906-021318-ladsgroup.json
01:58 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db1096:3316 (T314041)', diff saved to https://phabricator.wikimedia.org/P33812 and previous config saved to /var/cache/conftool/dbconfig/20220906-015812-ladsgroup.json
01:03 TimStarling: multi-DC stage 3: 2% of codfw/ulsfo/eqsin traffic going to codfw appservers, rolling out via puppet 00:54-01:24
00:03 ladsgroup@cumin1001: END (PASS) - Cookbook sre.hosts.downtime (exit_code=0) for 1 day, 0:00:00 on db1133.eqiad.wmnet with reason: Maintenance
00:03 ladsgroup@cumin1001: START - Cookbook sre.hosts.downtime for 1 day, 0:00:00 on db1133.eqiad.wmnet with reason: Maintenance
2022-09-05
23:22 ladsgroup@cumin1001: dbctl commit (dc=all): 'Depooling db1096:3316 (T314041)', diff saved to https://phabricator.wikimedia.org/P33811 and previous config saved to /var/cache/conftool/dbconfig/20220905-232237-ladsgroup.json
23:22 ladsgroup@cumin1001: END (PASS) - Cookbook sre.hosts.downtime (exit_code=0) for 1 day, 0:00:00 on db1096.eqiad.wmnet with reason: Maintenance
23:22 ladsgroup@cumin1001: START - Cookbook sre.hosts.downtime for 1 day, 0:00:00 on db1096.eqiad.wmnet with reason: Maintenance
23:22 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db1180 (T314041)', diff saved to https://phabricator.wikimedia.org/P33810 and previous config saved to /var/cache/conftool/dbconfig/20220905-232216-ladsgroup.json
23:07 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db1180', diff saved to https://phabricator.wikimedia.org/P33809 and previous config saved to /var/cache/conftool/dbconfig/20220905-230709-ladsgroup.json
22:52 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db1180', diff saved to https://phabricator.wikimedia.org/P33808 and previous config saved to /var/cache/conftool/dbconfig/20220905-225203-ladsgroup.json
22:36 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db1180 (T314041)', diff saved to https://phabricator.wikimedia.org/P33807 and previous config saved to /var/cache/conftool/dbconfig/20220905-223657-ladsgroup.json
21:24 ladsgroup@cumin1001: dbctl commit (dc=all): 'Depooling db1180 (T314041)', diff saved to https://phabricator.wikimedia.org/P33806 and previous config saved to /var/cache/conftool/dbconfig/20220905-212415-ladsgroup.json
21:24 ladsgroup@cumin1001: END (PASS) - Cookbook sre.hosts.downtime (exit_code=0) for 1 day, 0:00:00 on db1180.eqiad.wmnet with reason: Maintenance
21:23 ladsgroup@cumin1001: START - Cookbook sre.hosts.downtime for 1 day, 0:00:00 on db1180.eqiad.wmnet with reason: Maintenance
21:23 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db1165 (T314041)', diff saved to https://phabricator.wikimedia.org/P33805 and previous config saved to /var/cache/conftool/dbconfig/20220905-212343-ladsgroup.json
21:08 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db1165', diff saved to https://phabricator.wikimedia.org/P33804 and previous config saved to /var/cache/conftool/dbconfig/20220905-210837-ladsgroup.json
20:53 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db1165', diff saved to https://phabricator.wikimedia.org/P33803 and previous config saved to /var/cache/conftool/dbconfig/20220905-205330-ladsgroup.json
20:38 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db1165 (T314041)', diff saved to https://phabricator.wikimedia.org/P33802 and previous config saved to /var/cache/conftool/dbconfig/20220905-203824-ladsgroup.json
19:25 ladsgroup@cumin1001: dbctl commit (dc=all): 'Depooling db1165 (T314041)', diff saved to https://phabricator.wikimedia.org/P33801 and previous config saved to /var/cache/conftool/dbconfig/20220905-192554-ladsgroup.json
19:25 ladsgroup@cumin1001: END (PASS) - Cookbook sre.hosts.downtime (exit_code=0) for 2 days, 0:00:00 on clouddb[1015,1019,1021].eqiad.wmnet,db1155.eqiad.wmnet with reason: Maintenance
19:25 ladsgroup@cumin1001: START - Cookbook sre.hosts.downtime for 2 days, 0:00:00 on clouddb[1015,1019,1021].eqiad.wmnet,db1155.eqiad.wmnet with reason: Maintenance
19:25 ladsgroup@cumin1001: END (PASS) - Cookbook sre.hosts.downtime (exit_code=0) for 1 day, 0:00:00 on db1165.eqiad.wmnet with reason: Maintenance
19:25 ladsgroup@cumin1001: START - Cookbook sre.hosts.downtime for 1 day, 0:00:00 on db1165.eqiad.wmnet with reason: Maintenance
19:15 ladsgroup@cumin1001: dbctl commit (dc=all): 'db1165 (re)pooling @ 100%: Maint needs to be redone', diff saved to https://phabricator.wikimedia.org/P33800 and previous config saved to /var/cache/conftool/dbconfig/20220905-191532-ladsgroup.json
19:00 ladsgroup@cumin1001: dbctl commit (dc=all): 'db1165 (re)pooling @ 75%: Maint needs to be redone', diff saved to https://phabricator.wikimedia.org/P33799 and previous config saved to /var/cache/conftool/dbconfig/20220905-190027-ladsgroup.json
18:45 ladsgroup@cumin1001: dbctl commit (dc=all): 'db1165 (re)pooling @ 25%: Maint needs to be redone', diff saved to https://phabricator.wikimedia.org/P33798 and previous config saved to /var/cache/conftool/dbconfig/20220905-184522-ladsgroup.json
18:30 ladsgroup@cumin1001: dbctl commit (dc=all): 'db1165 (re)pooling @ 10%: Maint needs to be redone', diff saved to https://phabricator.wikimedia.org/P33797 and previous config saved to /var/cache/conftool/dbconfig/20220905-183017-ladsgroup.json
18:25 ladsgroup@cumin1001: END (PASS) - Cookbook sre.hosts.downtime (exit_code=0) for 1 day, 0:00:00 on db1132.eqiad.wmnet with reason: Maintenance
18:25 ladsgroup@cumin1001: START - Cookbook sre.hosts.downtime for 1 day, 0:00:00 on db1132.eqiad.wmnet with reason: Maintenance
18:25 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db1128 (T312863)', diff saved to https://phabricator.wikimedia.org/P33796 and previous config saved to /var/cache/conftool/dbconfig/20220905-182510-ladsgroup.json
18:10 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db1128', diff saved to https://phabricator.wikimedia.org/P33795 and previous config saved to /var/cache/conftool/dbconfig/20220905-181003-ladsgroup.json
17:54 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db1128', diff saved to https://phabricator.wikimedia.org/P33794 and previous config saved to /var/cache/conftool/dbconfig/20220905-175457-ladsgroup.json
17:54 ladsgroup@cumin1001: dbctl commit (dc=all): 'Depooling db2119 (T314041)', diff saved to https://phabricator.wikimedia.org/P33793 and previous config saved to /var/cache/conftool/dbconfig/20220905-175423-ladsgroup.json
17:54 ladsgroup@cumin1001: END (PASS) - Cookbook sre.hosts.downtime (exit_code=0) for 1 day, 0:00:00 on db2119.codfw.wmnet with reason: Maintenance
17:53 ladsgroup@cumin1001: START - Cookbook sre.hosts.downtime for 1 day, 0:00:00 on db2119.codfw.wmnet with reason: Maintenance
17:39 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db1128 (T312863)', diff saved to https://phabricator.wikimedia.org/P33792 and previous config saved to /var/cache/conftool/dbconfig/20220905-173951-ladsgroup.json
16:27 btullis@deploy1002: helmfile [eqiad] DONE helmfile.d/services/datahub: sync on main
16:26 btullis@deploy1002: helmfile [eqiad] START helmfile.d/services/datahub: sync on main
15:08 ladsgroup@cumin1001: dbctl commit (dc=all): 'Depooling db1165 (T314041)', diff saved to https://phabricator.wikimedia.org/P33791 and previous config saved to /var/cache/conftool/dbconfig/20220905-150837-ladsgroup.json
15:08 ladsgroup@cumin1001: END (PASS) - Cookbook sre.hosts.downtime (exit_code=0) for 2 days, 0:00:00 on clouddb[1015,1019,1021].eqiad.wmnet,db1155.eqiad.wmnet with reason: Maintenance
15:08 ladsgroup@cumin1001: START - Cookbook sre.hosts.downtime for 2 days, 0:00:00 on clouddb[1015,1019,1021].eqiad.wmnet,db1155.eqiad.wmnet with reason: Maintenance
15:08 ladsgroup@cumin1001: END (PASS) - Cookbook sre.hosts.downtime (exit_code=0) for 1 day, 0:00:00 on db1165.eqiad.wmnet with reason: Maintenance
15:08 ladsgroup@cumin1001: START - Cookbook sre.hosts.downtime for 1 day, 0:00:00 on db1165.eqiad.wmnet with reason: Maintenance
15:08 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db1168 (T314041)', diff saved to https://phabricator.wikimedia.org/P33790 and previous config saved to /var/cache/conftool/dbconfig/20220905-150758-ladsgroup.json
15:04 moritzm: updating docker.io on gitlab-runners
14:52 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db1168', diff saved to https://phabricator.wikimedia.org/P33789 and previous config saved to /var/cache/conftool/dbconfig/20220905-145252-ladsgroup.json
14:48 claime: Set wtp103[6-7].eqiad.wmnet inactive pending decommission T317025
14:40 cgoubert@cumin1001: END (PASS) - Cookbook sre.hosts.downtime (exit_code=0) for 7 days, 0:00:00 on wtp[1036-1038].eqiad.wmnet with reason: Downtiming replace wtp servers
14:40 cgoubert@cumin1001: START - Cookbook sre.hosts.downtime for 7 days, 0:00:00 on wtp[1036-1038].eqiad.wmnet with reason: Downtiming replace wtp servers
14:37 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db1168', diff saved to https://phabricator.wikimedia.org/P33788 and previous config saved to /var/cache/conftool/dbconfig/20220905-143746-ladsgroup.json
14:33 claime: depooled wtp1039.eqiad.wmnet from parsoid cluster T307219
14:23 claime: pooled parse1006.eqiad.wmnet (php 7.4 only) in parsoid cluster T307219
14:22 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db1168 (T314041)', diff saved to https://phabricator.wikimedia.org/P33786 and previous config saved to /var/cache/conftool/dbconfig/20220905-142240-ladsgroup.json
14:21 cgoubert@cumin1001: END (PASS) - Cookbook sre.hosts.remove-downtime (exit_code=0) for parse1006,parse1006.mgmt
14:21 cgoubert@cumin1001: START - Cookbook sre.hosts.remove-downtime for parse1006,parse1006.mgmt
13:13 btullis@cumin1001: END (FAIL) - Cookbook sre.hosts.reimage (exit_code=99) for host an-presto1011.eqiad.wmnet with OS bullseye
13:11 jmm@cumin2002: END (PASS) - Cookbook sre.hosts.downtime (exit_code=0) for 0:15:00 on puppetdb2002.codfw.wmnet with reason: Temporarily stop puppetdb
13:10 jmm@cumin2002: START - Cookbook sre.hosts.downtime for 0:15:00 on puppetdb2002.codfw.wmnet with reason: Temporarily stop puppetdb
13:10 urbanecm: UTC afternoon B&C window done
13:09 ladsgroup@cumin1001: dbctl commit (dc=all): 'Depooling db1168 (T314041)', diff saved to https://phabricator.wikimedia.org/P33785 and previous config saved to /var/cache/conftool/dbconfig/20220905-130944-ladsgroup.json
13:09 ladsgroup@cumin1001: END (PASS) - Cookbook sre.hosts.downtime (exit_code=0) for 1 day, 0:00:00 on db1168.eqiad.wmnet with reason: Maintenance
13:09 ladsgroup@cumin1001: START - Cookbook sre.hosts.downtime for 1 day, 0:00:00 on db1168.eqiad.wmnet with reason: Maintenance
13:05 btullis@cumin1001: END (PASS) - Cookbook sre.hosts.downtime (exit_code=0) for 2:00:00 on an-presto1011.eqiad.wmnet with reason: host reimage
13:01 btullis@cumin1001: START - Cookbook sre.hosts.downtime for 2:00:00 on an-presto1011.eqiad.wmnet with reason: host reimage
12:48 btullis@cumin1001: START - Cookbook sre.hosts.reimage for host an-presto1011.eqiad.wmnet with OS bullseye
12:47 btullis@cumin1001: END (ERROR) - Cookbook sre.hosts.reimage (exit_code=97) for host an-presto1007.eqiad.wmnet with OS bullseye
12:33 btullis@cumin1001: END (FAIL) - Cookbook sre.hosts.reboot-single (exit_code=1) for host datahubsearch1003.eqiad.wmnet
12:31 cgoubert@cumin1001: END (PASS) - Cookbook sre.hosts.remove-downtime (exit_code=0) for parse1005,parse1005.mgmt
12:31 cgoubert@cumin1001: START - Cookbook sre.hosts.remove-downtime for parse1005,parse1005.mgmt
12:24 btullis@cumin1001: START - Cookbook sre.hosts.reboot-single for host datahubsearch1003.eqiad.wmnet
12:22 btullis@cumin1001: END (PASS) - Cookbook sre.hosts.reboot-single (exit_code=0) for host datahubsearch1002.eqiad.wmnet
12:20 cgoubert@cumin1001: END (PASS) - Cookbook sre.hosts.downtime (exit_code=0) for 7 days, 0:00:00 on 18 hosts with reason: Downtime pending inclusion in production
12:20 cgoubert@cumin1001: START - Cookbook sre.hosts.downtime for 7 days, 0:00:00 on 18 hosts with reason: Downtime pending inclusion in production
12:18 btullis@cumin1001: START - Cookbook sre.hosts.reboot-single for host datahubsearch1002.eqiad.wmnet
12:16 btullis@cumin1001: START - Cookbook sre.hosts.reimage for host an-presto1007.eqiad.wmnet with OS bullseye
11:32 cgoubert@cumin1001: END (PASS) - Cookbook sre.hosts.downtime (exit_code=0) for 7 days, 0:00:00 on wtp[1034-1036].eqiad.wmnet with reason: Downtiming replaced wtp servers
11:32 cgoubert@cumin1001: START - Cookbook sre.hosts.downtime for 7 days, 0:00:00 on wtp[1034-1036].eqiad.wmnet with reason: Downtiming replaced wtp servers
11:23 ladsgroup@cumin1001: END (PASS) - Cookbook sre.hosts.downtime (exit_code=0) for 1 day, 0:00:00 on db1140.eqiad.wmnet with reason: Maintenance
11:23 ladsgroup@cumin1001: START - Cookbook sre.hosts.downtime for 1 day, 0:00:00 on db1140.eqiad.wmnet with reason: Maintenance
11:23 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db1187 (T314041)', diff saved to https://phabricator.wikimedia.org/P33783 and previous config saved to /var/cache/conftool/dbconfig/20220905-112308-ladsgroup.json
11:18 TimStarling: on db2142: stopped mariadb replication
11:16 tstarling@cumin1001: END (PASS) - Cookbook sre.hosts.downtime (exit_code=0) for 2:00:00 on db[2142-2144].codfw.wmnet with reason: T316847 x2 failure test
11:15 tstarling@cumin1001: START - Cookbook sre.hosts.downtime for 2:00:00 on db[2142-2144].codfw.wmnet with reason: T316847 x2 failure test
11:08 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db1187', diff saved to https://phabricator.wikimedia.org/P33782 and previous config saved to /var/cache/conftool/dbconfig/20220905-110801-ladsgroup.json
10:55 Emperor: set thanos ring replicas to 3.90 T311690
10:52 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db1187', diff saved to https://phabricator.wikimedia.org/P33781 and previous config saved to /var/cache/conftool/dbconfig/20220905-105255-ladsgroup.json
10:37 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db1187 (T314041)', diff saved to https://phabricator.wikimedia.org/P33780 and previous config saved to /var/cache/conftool/dbconfig/20220905-103749-ladsgroup.json
10:36 btullis@cumin1001: END (PASS) - Cookbook sre.hosts.reboot-single (exit_code=0) for host an-presto1015.eqiad.wmnet
06:28 ayounsi@cumin1001: END (PASS) - Cookbook sre.network.debug (exit_code=0) for Netbox interface ID cr2-eqiad:xe-4/1/3
06:28 ayounsi@cumin1001: START - Cookbook sre.network.debug for Netbox interface ID cr2-eqiad:xe-4/1/3
06:08 ladsgroup@cumin1001: END (PASS) - Cookbook sre.hosts.downtime (exit_code=0) for 1 day, 0:00:00 on db1119.eqiad.wmnet with reason: Maintenance
06:07 ladsgroup@cumin1001: START - Cookbook sre.hosts.downtime for 1 day, 0:00:00 on db1119.eqiad.wmnet with reason: Maintenance
02:46 ladsgroup@cumin1001: END (PASS) - Cookbook sre.hosts.downtime (exit_code=0) for 1 day, 0:00:00 on db2099.codfw.wmnet with reason: Maintenance
02:46 ladsgroup@cumin1001: START - Cookbook sre.hosts.downtime for 1 day, 0:00:00 on db2099.codfw.wmnet with reason: Maintenance
02:46 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db2138:3314 (T314041)', diff saved to https://phabricator.wikimedia.org/P33778 and previous config saved to /var/cache/conftool/dbconfig/20220905-024602-ladsgroup.json
00:36 ladsgroup@cumin1001: END (PASS) - Cookbook sre.hosts.downtime (exit_code=0) for 1 day, 0:00:00 on db1107.eqiad.wmnet with reason: Maintenance
00:36 ladsgroup@cumin1001: START - Cookbook sre.hosts.downtime for 1 day, 0:00:00 on db1107.eqiad.wmnet with reason: Maintenance
00:36 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db1106 (T312863)', diff saved to https://phabricator.wikimedia.org/P33777 and previous config saved to /var/cache/conftool/dbconfig/20220905-003619-ladsgroup.json
00:21 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db1106', diff saved to https://phabricator.wikimedia.org/P33776 and previous config saved to /var/cache/conftool/dbconfig/20220905-002112-ladsgroup.json
00:06 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db1106', diff saved to https://phabricator.wikimedia.org/P33775 and previous config saved to /var/cache/conftool/dbconfig/20220905-000606-ladsgroup.json
2022-09-04
23:51 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db1106 (T312863)', diff saved to https://phabricator.wikimedia.org/P33774 and previous config saved to /var/cache/conftool/dbconfig/20220904-235100-ladsgroup.json
22:50 ladsgroup@cumin1001: dbctl commit (dc=all): 'Depooling db1106 (T312863)', diff saved to https://phabricator.wikimedia.org/P33773 and previous config saved to /var/cache/conftool/dbconfig/20220904-225044-ladsgroup.json
22:50 ladsgroup@cumin1001: END (PASS) - Cookbook sre.hosts.downtime (exit_code=0) for 2 days, 0:00:00 on clouddb[1013,1017,1021].eqiad.wmnet,db1154.eqiad.wmnet with reason: Maintenance
22:50 ladsgroup@cumin1001: START - Cookbook sre.hosts.downtime for 2 days, 0:00:00 on clouddb[1013,1017,1021].eqiad.wmnet,db1154.eqiad.wmnet with reason: Maintenance
22:50 ladsgroup@cumin1001: END (PASS) - Cookbook sre.hosts.downtime (exit_code=0) for 1 day, 0:00:00 on db1106.eqiad.wmnet with reason: Maintenance
22:50 ladsgroup@cumin1001: START - Cookbook sre.hosts.downtime for 1 day, 0:00:00 on db1106.eqiad.wmnet with reason: Maintenance
22:50 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db1105:3311 (T312863)', diff saved to https://phabricator.wikimedia.org/P33772 and previous config saved to /var/cache/conftool/dbconfig/20220904-225016-ladsgroup.json
22:35 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db1105:3311', diff saved to https://phabricator.wikimedia.org/P33771 and previous config saved to /var/cache/conftool/dbconfig/20220904-223510-ladsgroup.json
22:20 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db1105:3311', diff saved to https://phabricator.wikimedia.org/P33770 and previous config saved to /var/cache/conftool/dbconfig/20220904-222004-ladsgroup.json
22:04 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db1105:3311 (T312863)', diff saved to https://phabricator.wikimedia.org/P33769 and previous config saved to /var/cache/conftool/dbconfig/20220904-220457-ladsgroup.json
15:51 ladsgroup@cumin1001: dbctl commit (dc=all): 'Depooling db1105:3311 (T312863)', diff saved to https://phabricator.wikimedia.org/P33767 and previous config saved to /var/cache/conftool/dbconfig/20220904-155059-ladsgroup.json
15:50 ladsgroup@cumin1001: END (PASS) - Cookbook sre.hosts.downtime (exit_code=0) for 1 day, 0:00:00 on db1105.eqiad.wmnet with reason: Maintenance
15:50 ladsgroup@cumin1001: START - Cookbook sre.hosts.downtime for 1 day, 0:00:00 on db1105.eqiad.wmnet with reason: Maintenance
15:50 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db1099:3311 (T312863)', diff saved to https://phabricator.wikimedia.org/P33766 and previous config saved to /var/cache/conftool/dbconfig/20220904-155027-ladsgroup.json
15:35 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db1099:3311', diff saved to https://phabricator.wikimedia.org/P33765 and previous config saved to /var/cache/conftool/dbconfig/20220904-153521-ladsgroup.json
15:20 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db1099:3311', diff saved to https://phabricator.wikimedia.org/P33764 and previous config saved to /var/cache/conftool/dbconfig/20220904-152015-ladsgroup.json
15:05 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db1099:3311 (T312863)', diff saved to https://phabricator.wikimedia.org/P33763 and previous config saved to /var/cache/conftool/dbconfig/20220904-150508-ladsgroup.json
12:51 elukey: reset-fail ifup@ens13.service on idp2002
12:50 elukey: reset-fail ifup@ens13.service on netflow4002
12:49 elukey: pkill remaining processes of user effeietsanders on stat1008 to unblock puppet - T314846
10:34 ladsgroup@cumin1001: dbctl commit (dc=all): 'Depooling db2138:3314 (T314041)', diff saved to https://phabricator.wikimedia.org/P33762 and previous config saved to /var/cache/conftool/dbconfig/20220904-103427-ladsgroup.json
10:34 ladsgroup@cumin1001: END (PASS) - Cookbook sre.hosts.downtime (exit_code=0) for 1 day, 0:00:00 on db2138.codfw.wmnet with reason: Maintenance
10:34 ladsgroup@cumin1001: START - Cookbook sre.hosts.downtime for 1 day, 0:00:00 on db2138.codfw.wmnet with reason: Maintenance
10:34 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db2136 (T314041)', diff saved to https://phabricator.wikimedia.org/P33761 and previous config saved to /var/cache/conftool/dbconfig/20220904-103405-ladsgroup.json
08:33 ladsgroup@cumin1001: dbctl commit (dc=all): 'Depooling db1099:3311 (T312863)', diff saved to https://phabricator.wikimedia.org/P33760 and previous config saved to /var/cache/conftool/dbconfig/20220904-083341-ladsgroup.json
08:33 ladsgroup@cumin1001: END (PASS) - Cookbook sre.hosts.downtime (exit_code=0) for 1 day, 0:00:00 on db1099.eqiad.wmnet with reason: Maintenance
08:33 ladsgroup@cumin1001: START - Cookbook sre.hosts.downtime for 1 day, 0:00:00 on db1099.eqiad.wmnet with reason: Maintenance
2022-09-03
23:50 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db1106 (T312863)', diff saved to https://phabricator.wikimedia.org/P33759 and previous config saved to /var/cache/conftool/dbconfig/20220903-235001-ladsgroup.json
23:34 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db1106', diff saved to https://phabricator.wikimedia.org/P33758 and previous config saved to /var/cache/conftool/dbconfig/20220903-233455-ladsgroup.json
23:19 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db1106', diff saved to https://phabricator.wikimedia.org/P33757 and previous config saved to /var/cache/conftool/dbconfig/20220903-231949-ladsgroup.json
23:04 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db1106 (T312863)', diff saved to https://phabricator.wikimedia.org/P33756 and previous config saved to /var/cache/conftool/dbconfig/20220903-230443-ladsgroup.json
22:04 ladsgroup@cumin1001: dbctl commit (dc=all): 'Depooling db1106 (T312863)', diff saved to https://phabricator.wikimedia.org/P33755 and previous config saved to /var/cache/conftool/dbconfig/20220903-220427-ladsgroup.json
22:04 ladsgroup@cumin1001: END (PASS) - Cookbook sre.hosts.downtime (exit_code=0) for 2 days, 0:00:00 on clouddb[1013,1017,1021].eqiad.wmnet,db1154.eqiad.wmnet with reason: Maintenance
22:03 ladsgroup@cumin1001: START - Cookbook sre.hosts.downtime for 2 days, 0:00:00 on clouddb[1013,1017,1021].eqiad.wmnet,db1154.eqiad.wmnet with reason: Maintenance
22:03 ladsgroup@cumin1001: END (PASS) - Cookbook sre.hosts.downtime (exit_code=0) for 1 day, 0:00:00 on db1106.eqiad.wmnet with reason: Maintenance
22:03 ladsgroup@cumin1001: START - Cookbook sre.hosts.downtime for 1 day, 0:00:00 on db1106.eqiad.wmnet with reason: Maintenance
22:03 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db1163 (T312863)', diff saved to https://phabricator.wikimedia.org/P33754 and previous config saved to /var/cache/conftool/dbconfig/20220903-220326-ladsgroup.json
21:48 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db1163', diff saved to https://phabricator.wikimedia.org/P33753 and previous config saved to /var/cache/conftool/dbconfig/20220903-214820-ladsgroup.json
21:33 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db1163', diff saved to https://phabricator.wikimedia.org/P33752 and previous config saved to /var/cache/conftool/dbconfig/20220903-213314-ladsgroup.json
21:18 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db1163 (T312863)', diff saved to https://phabricator.wikimedia.org/P33751 and previous config saved to /var/cache/conftool/dbconfig/20220903-211808-ladsgroup.json
18:01 ladsgroup@cumin1001: dbctl commit (dc=all): 'Depooling db2136 (T314041)', diff saved to https://phabricator.wikimedia.org/P33750 and previous config saved to /var/cache/conftool/dbconfig/20220903-180104-ladsgroup.json
18:00 ladsgroup@cumin1001: END (PASS) - Cookbook sre.hosts.downtime (exit_code=0) for 1 day, 0:00:00 on db2136.codfw.wmnet with reason: Maintenance
18:00 ladsgroup@cumin1001: START - Cookbook sre.hosts.downtime for 1 day, 0:00:00 on db2136.codfw.wmnet with reason: Maintenance
18:00 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db2147 (T314041)', diff saved to https://phabricator.wikimedia.org/P33749 and previous config saved to /var/cache/conftool/dbconfig/20220903-180042-ladsgroup.json
15:12 ladsgroup@cumin1001: dbctl commit (dc=all): 'Depooling db1163 (T312863)', diff saved to https://phabricator.wikimedia.org/P33748 and previous config saved to /var/cache/conftool/dbconfig/20220903-151224-ladsgroup.json
15:12 ladsgroup@cumin1001: END (PASS) - Cookbook sre.hosts.downtime (exit_code=0) for 1 day, 0:00:00 on db1163.eqiad.wmnet with reason: Maintenance
15:12 ladsgroup@cumin1001: START - Cookbook sre.hosts.downtime for 1 day, 0:00:00 on db1163.eqiad.wmnet with reason: Maintenance
09:45 ladsgroup@cumin1001: END (PASS) - Cookbook sre.hosts.downtime (exit_code=0) for 1 day, 0:00:00 on db2102.codfw.wmnet with reason: Maintenance
09:45 ladsgroup@cumin1001: START - Cookbook sre.hosts.downtime for 1 day, 0:00:00 on db2102.codfw.wmnet with reason: Maintenance
01:55 ladsgroup@cumin1001: dbctl commit (dc=all): 'Depooling db2147 (T314041)', diff saved to https://phabricator.wikimedia.org/P33747 and previous config saved to /var/cache/conftool/dbconfig/20220903-015524-ladsgroup.json
01:55 ladsgroup@cumin1001: END (PASS) - Cookbook sre.hosts.downtime (exit_code=0) for 1 day, 0:00:00 on db2147.codfw.wmnet with reason: Maintenance
01:55 ladsgroup@cumin1001: START - Cookbook sre.hosts.downtime for 1 day, 0:00:00 on db2147.codfw.wmnet with reason: Maintenance
01:55 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db2155 (T314041)', diff saved to https://phabricator.wikimedia.org/P33746 and previous config saved to /var/cache/conftool/dbconfig/20220903-015502-ladsgroup.json
20:40 ryankemper: T300943 New hosts are in service and were pooled like so: `sudo confctl select name=elastic20[73-86].* set/weight=10:pooled=yes` (in retrospect that syntax seems to have selected too many hosts, but the final state of pybal is correct per https://config-master.wikimedia.org/pybal/codfw/search)
20:39 pt1979@cumin2002: END (PASS) - Cookbook sre.hosts.provision (exit_code=0) for host db1203.mgmt.eqiad.wmnet with reboot policy FORCED
20:39 pt1979@cumin1001: END (PASS) - Cookbook sre.hosts.provision (exit_code=0) for host db1202.mgmt.eqiad.wmnet with reboot policy FORCED
20:24 thcipriani@deploy1002: thcipriani and ebernhardson: Backport for cirrus: Handle transition to elasticsearch 7.10 synced to the testservers: mwdebug1001.eqiad.wmnet, mwdebug2001.codfw.wmnet, mwdebug1002.eqiad.wmnet, mwdebug2002.codfw.wmnet
20:20 thcipriani@deploy1002: thcipriani and trainbranchbot: Backport for Revert "Deploy Research Incentive Survey to idwiki" synced to the testservers: mwdebug1001.eqiad.wmnet, mwdebug2001.codfw.wmnet, mwdebug2002.codfw.wmnet, mwdebug1002.eqiad.wmnet
20:13 pt1979@cumin2002: END (PASS) - Cookbook sre.hosts.provision (exit_code=0) for host db1201.mgmt.eqiad.wmnet with reboot policy FORCED
20:13 pt1979@cumin1001: END (PASS) - Cookbook sre.hosts.provision (exit_code=0) for host db1200.mgmt.eqiad.wmnet with reboot policy FORCED
20:13 thcipriani@deploy1002: thcipriani and dani: Backport for Deploy Research Incentive Survey to idwiki (T316466) synced to the testservers: mwdebug2002.codfw.wmnet, mwdebug1002.eqiad.wmnet, mwdebug2001.codfw.wmnet, mwdebug1001.eqiad.wmnet
16:29 topranks: Brining Lumen Tranport CCT 442550294 (cr1-codfw to cr4-ulsfo) back into service following successful hot-cut to lower-latency path with carrier
13:43 jmm@cumin2002: START - Cookbook sre.hosts.reboot-single for host netbox1002.eqiad.wmnet
13:41 jmm@cumin2002: END (PASS) - Cookbook sre.hosts.reboot-single (exit_code=0) for host netbox2002.codfw.wmnet
13:37 jmm@cumin2002: START - Cookbook sre.hosts.reboot-single for host netbox2002.codfw.wmnet
13:32 marostegui@cumin1001: END (PASS) - Cookbook sre.hosts.downtime (exit_code=0) for 1:00:00 on db[2135,2160].codfw.wmnet,db[1107,1117,1183].eqiad.wmnet with reason: switchover m5 T316744
13:31 marostegui@cumin1001: START - Cookbook sre.hosts.downtime for 1:00:00 on db[2135,2160].codfw.wmnet,db[1107,1117,1183].eqiad.wmnet with reason: switchover m5 T316744
12:29 herron: restarted thanos-query on thanos-fe1001
12:20 cdanis@cumin2002: dbctl commit (dc=all): 'T316482 remove replicas from x2', diff saved to https://phabricator.wikimedia.org/P33736 and previous config saved to /var/cache/conftool/dbconfig/20220901-122026-cdanis.json
12:13 klausman@cumin1001: END (PASS) - Cookbook sre.hosts.remove-downtime (exit_code=0) for ml-serve-ctrl1001.eqiad.wmnet
12:13 klausman@cumin1001: START - Cookbook sre.hosts.remove-downtime for ml-serve-ctrl1001.eqiad.wmnet
12:13 ladsgroup@cumin1001: END (PASS) - Cookbook sre.hosts.downtime (exit_code=0) for 1 day, 0:00:00 on db1150.eqiad.wmnet with reason: Maintenance
12:12 ladsgroup@cumin1001: START - Cookbook sre.hosts.downtime for 1 day, 0:00:00 on db1150.eqiad.wmnet with reason: Maintenance
12:12 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db1146:3314 (T314041)', diff saved to https://phabricator.wikimedia.org/P33735 and previous config saved to /var/cache/conftool/dbconfig/20220901-121252-ladsgroup.json
12:05 klausman@cumin1001: END (PASS) - Cookbook sre.hosts.downtime (exit_code=0) for 1:00:00 on ml-serve-ctrl1001.eqiad.wmnet with reason: Reboot to pick up kernel 5.10.136 (T316185)
12:05 klausman@cumin1001: START - Cookbook sre.hosts.downtime for 1:00:00 on ml-serve-ctrl1001.eqiad.wmnet with reason: Reboot to pick up kernel 5.10.136 (T316185)
12:03 klausman@cumin1001: END (PASS) - Cookbook sre.k8s.reboot-nodes (exit_code=0) rolling reboot on A:ml-serve-worker-eqiad
11:59 moritzm: rebalance row B after completed Bullseye updates T311686
11:57 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db1146:3314', diff saved to https://phabricator.wikimedia.org/P33734 and previous config saved to /var/cache/conftool/dbconfig/20220901-115746-ladsgroup.json
11:48 cdanis: root@apt1001:/home/cdanis/build-area# reprepro --ignore=wrongdistribution -C main include bullseye-wikimedia conftool_2.2.2-1_amd64.changes
11:42 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db1146:3314', diff saved to https://phabricator.wikimedia.org/P33733 and previous config saved to /var/cache/conftool/dbconfig/20220901-114239-ladsgroup.json
11:27 ladsgroup@cumin1001: dbctl commit (dc=all): 'Repooling after maintenance db1146:3314 (T314041)', diff saved to https://phabricator.wikimedia.org/P33732 and previous config saved to /var/cache/conftool/dbconfig/20220901-112733-ladsgroup.json
08:18 jmm@cumin2002: END (PASS) - Cookbook sre.ganeti.addnode (exit_code=0) for new host ganeti2015.codfw.wmnet to cluster codfw and group D
08:17 cgoubert@cumin1001: END (PASS) - Cookbook sre.hosts.downtime (exit_code=0) for 7 days, 0:00:00 on parse1002.eqiad.wmnet with reason: Readding downtime removed by reimage
08:17 cgoubert@cumin1001: START - Cookbook sre.hosts.downtime for 7 days, 0:00:00 on parse1002.eqiad.wmnet with reason: Readding downtime removed by reimage
08:17 jmm@cumin2002: START - Cookbook sre.ganeti.addnode for new host ganeti2015.codfw.wmnet to cluster codfw and group D
08:02 jmm@cumin2002: END (PASS) - Cookbook sre.hosts.reboot-single (exit_code=0) for host ganeti2015.codfw.wmnet
07:56 oblivian@deploy1002: Synchronized wmf-config/InitialiseSettings.php: Moving 1% of traffic to php 7.4 (duration: 03m 42s)
07:51 jmm@cumin2002: START - Cookbook sre.hosts.reboot-single for host ganeti2015.codfw.wmnet
07:32 jmm@cumin2002: END (PASS) - Cookbook sre.hosts.reimage (exit_code=0) for host ganeti2015.codfw.wmnet with OS bullseye
07:13 jmm@cumin2002: END (PASS) - Cookbook sre.hosts.downtime (exit_code=0) for 2:00:00 on ganeti2015.codfw.wmnet with reason: host reimage
07:10 jmm@cumin2002: START - Cookbook sre.hosts.downtime for 2:00:00 on ganeti2015.codfw.wmnet with reason: host reimage
06:50 jmm@cumin2002: START - Cookbook sre.hosts.reimage for host ganeti2015.codfw.wmnet with OS bullseye
06:37 ladsgroup@cumin1001: END (PASS) - Cookbook sre.hosts.downtime (exit_code=0) for 1 day, 0:00:00 on db1136.eqiad.wmnet with reason: Maintenance
06:37 ladsgroup@cumin1001: START - Cookbook sre.hosts.downtime for 1 day, 0:00:00 on db1136.eqiad.wmnet with reason: Maintenance
06:25 oblivian@deploy1002: Synchronized wmf-config/InitialiseSettings.php: Reverting to no php 7.4 traffic (duration: 03m 44s)
06:19 ladsgroup@cumin1001: END (PASS) - Cookbook sre.hosts.downtime (exit_code=0) for 10:00:00 on db1136.eqiad.wmnet with reason: Maintenance
06:18 ladsgroup@cumin1001: START - Cookbook sre.hosts.downtime for 10:00:00 on db1136.eqiad.wmnet with reason: Maintenance
06:10 oblivian@deploy1002: Synchronized wmf-config/InitialiseSettings.php: Moving 1% of users to php 7.4 (duration: 03m 55s)
06:09 ladsgroup@cumin1001: dbctl commit (dc=all): 'Depool db1136 T316111', diff saved to https://phabricator.wikimedia.org/P33729 and previous config saved to /var/cache/conftool/dbconfig/20220901-060923-ladsgroup.json
06:01 ladsgroup@cumin1001: dbctl commit (dc=all): 'Promote db1181 to s7 primary and set section read-write T316111', diff saved to https://phabricator.wikimedia.org/P33728 and previous config saved to /var/cache/conftool/dbconfig/20220901-060128-ladsgroup.json
06:01 ladsgroup@cumin1001: dbctl commit (dc=all): 'Set s7 eqiad as read-only for maintenance - T316111', diff saved to https://phabricator.wikimedia.org/P33727 and previous config saved to /var/cache/conftool/dbconfig/20220901-060100-ladsgroup.json
06:00 Amir1: Starting s7 eqiad failover from db1136 to db1181 - T316111
05:17 ladsgroup@cumin1001: dbctl commit (dc=all): 'Set db1181 with weight 0 T316111', diff saved to https://phabricator.wikimedia.org/P33726 and previous config saved to /var/cache/conftool/dbconfig/20220901-051701-ladsgroup.json
05:16 ladsgroup@cumin1001: END (PASS) - Cookbook sre.hosts.downtime (exit_code=0) for 1:00:00 on 28 hosts with reason: Primary switchover s7 T316111
05:16 ladsgroup@cumin1001: START - Cookbook sre.hosts.downtime for 1:00:00 on 28 hosts with reason: Primary switchover s7 T316111
01:20 eevans@cumin1001: END (PASS) - Cookbook sre.cassandra.roll-restart (exit_code=0) for nodes matching restbase201[3-8].codfw.wmnet: Restart to apply new certificates (T316697) - eevans@cumin1001
00:21 eevans@cumin1001: START - Cookbook sre.cassandra.roll-restart for nodes matching restbase201[3-8].codfw.wmnet: Restart to apply new certificates (T316697) - eevans@cumin1001