Incidents/2022-02-01 ulsfo network
Appearance
(Redirected from Incident documentation/2022-02-01 ulsfo network)
document status: in-review
Summary
| Incident ID | 2022-02-01 ulsfo network | Start | 2022-01-31 16:05 |
|---|---|---|---|
| Task | No task | End | 2022-01-31 16:08 |
| People paged | 20+ | Responder count | 6+ |
| Coordinators | 0 | Affected metrics/SLOs | |
| Impact | For 3 minutes, clients served by the ulsfo POP were not able to contribute or display un-cached pages. 8000 errors per minute (HTTP 5xx). | ||
A firewall change was pushed to ulsfo routers, which caused ulsfo to lose connectivity to the other POPs and core sites for 3min.
Timeline
- 16:03 - apply configuration change on cr3-ulsfo
- 16:05 - apply configuration change on cr4-ulsfo - outage starts
- 16:06 - Icinga notifies about connectivity issues to ulsfo - paging
- 16:08 - change rolled back - outage ends
Documentation:
Root cause:
The change incorrectly restricts BFD to BGP peers:
+ term allow_bfd {
+ from {
+ source-prefix-list {
+ bgp-sessions;
+ }
+ protocol udp;
+ port 3784-3785;
+ }
+ then accept;
+ }
While BFD is also used by OSPF sessions, which caused them to be tear down.
One surprising point is that the issue didn't show up in the verification commands (show ospf interfaces, show ospf neighbors), all neighbors are present.
show ospf interface
Interface State Area DR ID BDR ID Nbrs
ae0.2 PtToPt 0.0.0.0 0.0.0.0 0.0.0.0 1
et-0/0/1.401 PtToPt 0.0.0.0 0.0.0.0 0.0.0.0 1
xe-0/1/1.0 PtToPt 0.0.0.0 0.0.0.0 0.0.0.0 1
show ospf neighbor
Address Interface State ID Pri Dead
198.35.26.197 ae0.2 Full 198.35.26.193 128 35
198.35.26.199 et-0/0/1.401 Full 198.35.26.194 128 33
198.35.26.209 xe-0/1/1.0 Full 208.80.154.198 128 34
While it was effectively down:
rpd[16292]: RPD_OSPF_NBRDOWN: OSPF neighbor 198.35.26.209 (realm ospf-v2 xe-0/1/1.0 area 0.0.0.0) state changed from Full to Down due to InActiveTimer (event reason: BFD session timed out and neighbor was declared dead)
Conclusion
- More progressive roll out (longer wait time between each routers, as well as fewer changes at a time) could have reduced the risk of the issue happening
- Monitoring properly caught the issue
Scorecard
| Question | Score | Notes | |
|---|---|---|---|
| People | Were the people responding to this incident sufficiently different than the previous five incidents? (score 1 for yes, 0 for no) | 0 | |
| Were the people who responded prepared enough to respond effectively (score 1 for yes, 0 for no) | 1 | ||
| Were more than 5 people paged? (score 0 for yes, 1 for no) | 1 | ||
| Were pages routed to the correct sub-team(s)? (score 1 for yes, 0 for no) | 1 | ||
| Were pages routed to online (business hours) engineers? (score 1 for yes, 0 if people were paged after business hours) | 1 | ||
| Process | Was the incident status section actively updated during the incident? (score 1 for yes, 0 for no) | 0 | |
| Was the public status page updated? (score 1 for yes, 0 for no) | 0 | ||
| Is there a phabricator task for the incident? (score 1 for yes, 0 for no) | 0 | ||
| Are the documented action items assigned? (score 1 for yes, 0 for no) | 0 | ||
| Is this a repeat of an earlier incident (score 0 for yes, 1 for no) | 0 | ||
| Tooling | Was there, before the incident occurred, open tasks that would prevent this incident / make mitigation easier if implemented? (score 0 for yes, 1 for no) | 1 | |
| Were the people responding able to communicate effectively during the incident with the existing tooling? (score 1 for yes, 0 or no) | 1 | ||
| Did existing monitoring notify the initial responders? (score 1 for yes, 0 for no) | 1 | ||
| Were all engineering tools required available and in service? (score 1 for yes, 0 for no) | 1 | ||
| Was there a runbook for all known issues present? (score 1 for yes, 0 for no) | 1 | ||
| Total score | 9 | ||