There were several problems with the 2018-08-21 1.32.0-wmf.18 train resulting in multiple rollbacks.
Stats
- changes: 755
- repos: 176
- committers: 89
- finished on-time: true
- rollbacks: 2
- issues: 6
- Changelog
Issues
- Bad newline after return statement by JavaScript minifier
- jsonconfig-license-notice-license-unset showing up on non-tabular data pages
- Call to a member function getRevisionRecord() on a non-object (boolean)
- www.mediawiki.org showing: error:Unknown database 'wikidatawiki' on shard: s3
- BadMethodCallException from line 3671 of /srv/mediawiki/php-1.32.0-wmf.18/includes/parser/Parser.php: Call to a member function getId() on a non-object (boolean)
- prepareForParse() nor setReviewedVersions() called yet
Timeline
2018-08-09
2018-08-17
2018-08-21
- 11:57: jsonconfig-license-notice-license-unset showing up on non-tabular data pages
- 17:13: thcipriani: starting branch cut for 1.32.0-wmf.18
- 18:52: Pruned MediaWiki: 1.32.0-wmf.10 (duration: 07m 37s)
- 18:58: Pruned MediaWiki: 1.32.0-wmf.12 (duration: 03m 15s)
- 19:11: Pruned MediaWiki: 1.32.0-wmf.13 (duration: 01m 41s)
- 19:49: Finished scap: testwiki to php-1.32.0-wmf.18 and rebuild l10n cache (duration: 34m 54s)
- 20:11: [Group0] rebuilt and synchronized wikiversions files: Group0 to 1.32.0-wmf.18
- 20:40: Call to a member function getRevisionRecord() on a non-object (boolean)
- 17:41: www.mediawiki.org showing: error:Unknown database 'wikidatawiki' on shard: s3
End of Day Summary
- Group0: 1.32.0-wmf.18
- Group1: 1.32.0-wmf.16
- Group2: 1.32.0-wmf.16
- Status:
Not done
2018-08-22
- 00:10:
www.mediawiki.org showing: error:Unknown database 'wikidatawiki' on shard: s3 - 05:32:
jsonconfig-license-notice-license-unset showing up on non-tabular data pages - 19:38: Synchronized php-1.32.0-wmf.18/extensions/Flow/includes/TemplateHelper.php: Work around exception in DifferenceEngine::showDiffStyle() phab:T202454
- 19:40: Removed phab:T202454 as blocker:
Call to a member function getRevisionRecord() on a non-object (boolean) - 19:54: [Group1] rebuilt and synchronized wikiversions files: group1 wikis to 1.32.0-wmf.18
- 20:24:
[Group1]rebuilt and synchronized wikiversions files: Revert "Group1 wikis to 1.32.0-wmf.18" - 20:27: BadMethodCallException from line 3671 of /srv/mediawiki/php-1.32.0-wmf.18/includes/parser/Parser.php: Call to a member function getId() on a non-object (boolean)
End of Day Summary
- Group0: 1.32.0-wmf.18
- Group1: 1.32.0-wmf.16
- Group2: 1.32.0-wmf.16
- Status:
Not done
2018-08-23
- 18:28: Synchronized php-1.32.0-wmf.18/extensions/FlaggedRevs/backend/FlaggedRevs.class.php: Fix incorrect return value in CurrentRevisionCallback phab:T202580 (duration: 00m 54s)
- 18:37: [Group1] rebuilt and synchronized wikiversions files: group1 wikis to 1.32.0-wmf.18
- 18:45:
BadMethodCallException from line 3671 of /srv/mediawiki/php-1.32.0-wmf.18/includes/parser/Parser.php: Call to a member function getId() on a non-object (boolean) - 19:26: [Group2] rebuilt and synchronized wikiversions files: all wikis to 1.32.0-wmf.18
- 19:34:
[Group2]rebuilt and synchronized wikiversions files: revert all wikis to 1.32.0-wmf.18 - 19:38: prepareForParse() nor setReviewedVersions() called yet
- 22:27: Synchronized php-1.32.0-wmf.18/extensions/FlaggedRevs/backend/FlaggedRevs.class.php: Follow-up 413e11e2f: Skip CurrentRevisionCallback if not stabilized T202659 (duration: 00m 56s)
- 22:31: [Group2] rebuilt and synchronized wikiversions files: all wikis to 1.32.0-wmf.18
- 22:37:
prepareForParse() nor setReviewedVersions() called yet
End of Day Summary
- Group0: 1.32.0-wmf.18
- Group1: 1.32.0-wmf.18
- Group2: 1.32.0-wmf.18
- Status:
Done