Summary
On Friday, June 15th 2018, Phabricator was vandalized by an attacker who randomly reassigned tasks, dropped members from projects, posted random gibberish comments, altered task priorities, merged tasks, etc.
Timeline
- 2018-06-15 07:50: Vandal creates Phabricator account 238482n375
- 2018-06-15 08:01 to 08:08: 238482n375 starts to edit tasks (edited projects: added Analytics-Kanban, Security, Wikimedia-VE-Campaigns (S2-2018), Scap (Scap3-Adoption-Phase2), AbuseFilter, Data-release, Hashtags, LabsDB-Auditor, Ladies-That-FOSS-MediaWiki, Language-2018-Apr-June, Language-2018-Jan-Mar, HHVM, HAWelcome; edited projects: removed Cloud-Services, Tools; set Priority field to Lowest; removed task assignee; moved task from Next Up to In Code Review on the Analytics-Kanban board; added subscriber 238482n375; removed subscriber Aklapper; and/or: set the Security field to Software security bug to change task visibility)
- 2018-06-15 08:08: Volans and JAlexander disable Phabricator account 238482n375
- 2018-06-15 08:12: Vandal creates Phabricator account Hfewjfjjsjjksa
- 2018-06-15 08:18: Vandal creates Phabricator account Dnvjdvsj
- 2018-06-15 08:30: Hfewjfjjsjjksa creates 161 tasks
- 2018-06-15 08:30: AKlapper disables Phabricator account Hfewjfjjsjjksa
- 2018-06-15 08:33: AKlapper disables Phabricator account Dnvjdvsj
- 2018-06-15 08:50: Discussions about potential conclusions start (phab:T162026#4289748, IRC)
- 2018-06-15: Several people (akosiaris, Ladsgroup, mutante, Volans, AKlapper, etc) revert those actions
- 2018-06-15 14:10: mmodell temporarily enables
auth.require-approvalin the Phabricator configuration - 2018-06-16 22:47: Vandal creates Phabricator account Ndscnjd (no activity as
auth.require-approvalwas enabled; account disabled later) - 2018-06-17 01:31: Vandal creates Phabricator account Jsdhmvdj (no activity as
auth.require-approvalwas enabled; account disabled later) - 2018-06-19 mmodell locks down the 'Lock as security issue' feature
- 2018-06-20 04:35: Vandal unsuccessfully tries to log into their already disabled older Phabricator account Ahmed123
- 2018-06-27 06:00: tstarling disables
auth.require-approval- phab:T197550#4318144 - 2018-06-30 02:38: Vandal creates Phabricator account Vvjjkkii
- 2018-07-01 01:01: Vvjjkkii starts to edit tasks
- 2018-07-01 01:05: Paladox files phab:T198547 about blocking the account Vvjjkkii
- 2018-07-01 01:14: bd808 disables Phabricator account Vvjjkkii
- 2018-07-01 01:53: greg reenables
auth.require-approvaland informs the community in https://lists.wikimedia.org/pipermail/wikitech-l/2018-July/090269.html - 2018-07-01: Many people start to manually revert the edits
- 2018-07-01 05:12: phab:p/Community_Tech_Bot/ (later renamed to phab:p/CommunityTechBot/) starts to revert the edits
- 2018-07-01 06:16: Rate limiting patch by mmodell in https://gerrit.wikimedia.org/r/#/c/operations/puppet/+/441525/ gets merged - phab:T197922
- 2018-07-01 06:28: Jsamwrites files phab:T198552 about reverting the edits
- 2018-07-02 16:58: phab:p/CommunityTechBot/ finishes, Musikanimal summarizes in https://lists.wikimedia.org/pipermail/wikitech-l/2018-July/090283.html
Conclusions
- It's more work than it should be to revert the damage done by a bad actor.
- Phabricator has weak anti-vandalism features, we need to improve them. See subtasks of phab:T84.
Actionables
Done Short-term: Enable manual approval of new user accounts in Phab - phab:T197550
Done Lock down the 'Lock as security issue' feature - phab:D1069, phab:rPHEXf951c8bfa70a1d4f561ebd82cdbbcf9a619172fa
Done Reinstate phabricator request rate limits - phab:T197922
Done Exclude offices from rate limits - phab:T198612
Done Implement rate limiting on edits (AWA) - phab:T199741- Allow reverting all actions by one single user in a recent timeframe - phab:T198283
Short-term: Block IPs: gerrit:440510
Done Revert manual approval of new user accounts in Phab - phab:T197550 on 2018-08-09